1 daripada 1

Beckhoff EPI1809-0022 IO-Link Box

Beckhoff EPI1809-0022 IO-Link Box

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: EPI1809-0022

  • Negara asal:Jerman

  • Jenis Produk: IO-Link Box Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Facilitating decentralized field signal acquisition, the Beckhoff EPI1809-0022 interfaces sixteen 24 V DC digital inputs directly to an IO-Link master. This highly compact IO-Link box allows sensors to be connected directly in the field without requiring a protective electrical enclosure. The module operates as an IO-Link Class A device, exchanging process data and configuration parameters over a standardized point-to-point communication channel. The robust structural encapsulation ensures reliable functionality in harsh manufacturing zones where dust, moisture, and high mechanical vibration are prevalent.

Features

  • 16 Digital Inputs: High-density distribution with Type 3 input characteristics according to EN 61131-2.
  • IO-Link V1.1 Compliance: Supports the Class A specification with high-speed COM3 communication rates.
  • Configurable Filters: Input filter times are adjustable from 0 to 20 ms to accommodate various sensor responses.
  • Integrated Sensor Protection: A collective 0.5 A sensor supply is fully protected against short-circuit events.
  • Heavy-Duty Seal: IP65, IP66, and IP67 protection ratings enable direct field mounting.

Applications

  • Automotive assembly lines and conveyor networks.
  • Decentralized input monitoring on large packaging machinery.
  • Machine-mount sensor aggregation in washdown or wet processing areas.
  • Robotic end-of-arm tooling requiring lightweight signal hubs.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation GmbH & Co. KG
Model Number EPI1809-0022
Communication Protocol IO-Link
IO-Link Specification Version V1.1, Class A
Data Transfer Rate 230.4 kbaud (COM3)
Primary Interface 1 x M12 plug, A-coded
Number of Inputs 16
Input Connections M12, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Range 3.0 ms (default), adjustable from 0 to 20 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 3)
Input Current Typical 3 mA (EN 61131-2, type 3)
Sensor Supply Maximum 0.5 A from L+, short-circuit proof in total
Current Consumption Typical 100 mA from L+
Operating Temperature -25 to +60 Celsius
Storage Temperature -40 to +85 Celsius
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration & Shock Standards Conforms to EN 60068-2-6 and EN 60068-2-27
EMC Immunity & Emission Conforms to EN 61000-6-2 and EN 61000-6-4
Approvals CE, UL
Module Weight 250 g
Shipping Weight 2.0 kg
Country of Origin Germany

Empirical Engineering Insights

Alternative Models & Compatibility

The EPI1809-0022 uses Class A port assignment. Note that when replacing an older EP1809-0022 module, the control system must be adapted because the EP series operates natively on EtherCAT (requiring an EtherCAT master and XML descriptions), whereas the EPI series uses the IO-Link physical protocol layer under a master gateway. Verify that the master IO-Link port pinout matches the standard Class A configuration before commissioning.

Application Pitfalls & Engineering Notes

A common issue in field installations is overloading the sensor supply line. While individual input current is restricted to typical Type 3 parameters (3 mA), the aggregate sensor supply is capped at 0.5 A. If several high-current photo-electric proximity sensors or ultrasonic transducers are powered directly from this unit, the short-circuit protection mechanism will engage, shutting down auxiliary sensor power. Ensure a power budget calculation is done for all 16 connected devices.

Commissioning & Wiring Tips

When pairing the device with non-Beckhoff IO-Link masters, ensure that the correct manufacturer IODD configuration file is loaded into the engineering software (such as TwinCAT or TIA Portal) to correctly map the 16-channel process image. Tighten all unused M12 connections with protective caps to maintain the IP67 integrity; failure to seal unused ports can allow condensation to bridge contacts over time, causing intermittent "0" and "1" signal faults.

Installation Guidelines

CRITICAL WARNING: Prior to commencing any mechanical mounting or cable connection steps, completely de-energize the main 24 V DC system supply line to the IO-Link master unit. Do not plug or unplug M12 cables while under electrical load, as contact-arcing could damage sensitive semiconductor components in the internal transceiver circuit.
1

Mount the module directly to a flat, vibration-resistant surface using two M4 screws through the integrated chassis mounting holes. Ensure the installation position allows for adequate cable strain relief.

2

Securely plug the A-coded M12 IO-Link communication cable into the module's communication port and hand-tighten the coupling nut.

3

Connect the 16 digital input sensors to the appropriate M12 input channels. Utilize standard torque wrenches for M12 connectors to guarantee environmental sealing without over-tightening.

4

Power up the master system and configure the corresponding input filter settings and channel maps within your automation development workspace.

Loading product navigation…

Can the Beckhoff EPI1809-0022 be used on a Class B IO-Link master port?

Yes, it can be physically connected to a Class B master port, but it will only operate using the Class A pin configuration. Pin 2 and Pin 5 auxiliary supply lines of a Class B port are not utilized by this module.

What happens if a sensor line short-circuits on the EPI1809-0022?

The module features an integrated short-circuit proof sensor supply. If a fault is detected, the sensor power is limited to prevent hardware damage, and a diagnostic flag is raised in the IO-Link process data.

How are the input filters configured on this IO-Link box?

The input filters can be adjusted within a range of 0 to 20 ms (with a default setting of 3.0 ms) via the IO-Link parameters using your master's software tool or acyclic commands.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...