1 daripada 1

Beckhoff EPP5101-1002 EtherCAT P Box Antara Muka Pengekod Inkremental 1-Saluran

Beckhoff EPP5101-1002 EtherCAT P Box Antara Muka Pengekod Inkremental 1-Saluran

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: EPP5101-1002

  • Negara asal:Jerman

  • Jenis Produk: Modul I/O EtherCAT

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 150 x 50 x 50 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for direct field deployment in decentralized architectures, the Beckhoff EPP5101-1002 provides a high-performance interface for incremental encoders using RS422 differential or TTL single-ended signals. This robust IP67-rated module is part of the EtherCAT P system, merging high-speed communication and power delivery into a single, unified cable. By processing differential signals (A, B, C) directly on the machine, the module eliminates long analog wiring runs and significantly reduces electromagnetic interference (EMI) risks in demanding industrial installations.

Features

  • Universal Encoder Interface: Supports RS422 differential, TTL single-ended, counter, and pulse generator modes.
  • EtherCAT P Cabling: Combines EtherCAT communication and dual power supplies (Us for system/sensors, Up for peripherals) into a single, P-coded M8 connector.
  • High-Speed Processing: Features a limit frequency of up to 1 MHz, matching 4 million increments per second with 4-fold evaluation.
  • Distributed Clocks: Native support for synchronized sub-microsecond system timestamping.
  • Industrial Protection: IP65, IP66, and IP67 sealed zinc die-cast housing for screw-mounting directly on machine frames without an electrical cabinet.

Applications

  • Precision Motion Control: Real-time positioning feedback in packaging machinery and material handling systems.
  • Rotary and Linear Feedback: direct interfacing to high-resolution quadrature encoders on servo axes.
  • Harsh Environment Mounting: Distributed I/O setups in food processing, washdown areas, and automotive assembly lines.

Technical Specifications

Parameter Value
Manufacturer Beckhoff
Model Number EPP5101-1002
Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Connection Technology M12, 8-pin, screw type (A-coded)
Number of Channels 1
Encoder Signals A, A (inv), B, B (inv), C, C (inv) differential inputs
Encoder Operating Voltage 24 V DC / 0.5 A (derived from Us supply)
Nominal Voltage 24 V DC (-15% / +20%)
Counter Capacity 16 or 32 bit, binary
Limit Frequency 1 MHz (4 million increments/s with 4-fold evaluation)
Current Consumption (Us) Typically 100 mA
Electrical Isolation 500 V RMS
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Protection Class IP65/66/67 (conforms to EN 60529)
Country of Origin Germany
Shipping Weight (Calculated) 0.5 kg
Package Dimensions (Calculated) 150 x 50 x 50 mm

Connections and Interfaces

M12 Pin Signal Assignment Function
1 A Encoder Channel A (Non-inverted Input)
2 A (inv) Encoder Channel A (Inverted Input)
3 B Encoder Channel B (Non-inverted Input)
4 B (inv) Encoder Channel B (Inverted Input)
5 C / Zero Latch/Zero-Pulse Input (Non-inverted)
6 C (inv) Latch/Zero-Pulse Input (Inverted)
7 GND Reference Ground for Encoder Power
8 +24 V DC Auxiliary Encoder Sensor Supply Output

Empirical Engineering Insights

Alternative Models & Compatibility

The EPP5101-1002 is specifically built for EtherCAT P (P-coded physical interface). Note that it cannot be plugged directly into standard EtherCAT (EP5101-0002) networks without the use of an EP9224 or EP9214 junction box, which breaks out communication and the respective Us/Up power lines. TwinCAT 3 requires standard ESI file updates to correctly recognize the EPP series hardware versions.

Application Pitfalls & Engineering Notes

When configuring downstream EtherCAT P nodes, verify that the total cumulative current drawn from the Us (system/sensor power) loop does not exceed the line thresholds. High-resolution, multi-channel linear encoders can cause significant voltage drops across long M8 P-coded link lines, triggering under-voltage fault codes in TwinCAT.

Commissioning & Wiring Tips

To ensure stable 1 MHz count operations, utilize double-shielded twisted-pair cabling for all differential M12 encoder runs. Standard single-ended TTL encoders are more susceptible to ambient motor-drive noise; hence, we highly recommend terminating the cable shield completely 360 degrees around the metallic M12 plug shell.

Installation Guidelines

CRITICAL WARNING:

Isolate all electrical power sources before handling, installing, or servicing EtherCAT P physical connectors. Ensure the field cables are not under load during coupling to prevent arcing and connector degradation on the sensitive P-coded gold pins.

1

Mount the module on a flat machine surface using standard M3 screws. Ground the mounting tabs directly to the frame to ensure maximum EMI immunity.

2

Connect the incoming EtherCAT P M8 cable to the P-coded input socket, hand-tightening to IP67 specifications (typically 0.4 Nm torque).

3

Install the M12 encoder interface cable to the bottom connection port. Protect any unused M8 or M12 interfaces with industrial plastic dust caps to preserve the IP67 housing seal integrity.

Loading product navigation…

What is the maximum signal frequency supported by this interface module?

The module supports an input frequency of up to 1 MHz. With 4-fold evaluation, this corresponds to a high-speed counting capability of 4 million increments per second.

Can I connect this module directly to a standard EtherCAT network?

No, because it uses an EtherCAT P-coded physical M8 interface that integrates power (Us/Up) and data. To bridge to standard EtherCAT, a distribution junction such as the Beckhoff EP9224-0002 is required.

Is the encoder power supply isolated from the logic supply?

The module features an overall electrical isolation rating of 500 V, providing decoupling between field signals and the standard internal bus communications logic.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...