1 daripada 1

Beckhoff ER6001-0002 EtherCAT Box Serial Interface Module

Beckhoff ER6001-0002 EtherCAT Box Serial Interface Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: ER6001-0002

  • Negara asal:Jerman

  • Jenis Produk: Serial Interface Modules

  • Pembayaran: T/T, Western Union

  • Berat: 265g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for direct connection of serial devices to EtherCAT networks without an electrical cabinet, the Beckhoff ER6001-0002 serial interface module provides a highly ruggedized, IP67-rated solution for industrial field installations. This module enables the seamless integration of devices featuring RS232, RS422, or RS485 interfaces directly into the EtherCAT communication ring. The interface type is individually selectable per channel, allowing versatile configuration based on system requirements.

Equipped with an integrated 5 V DC sensor supply and auxiliary digital inputs and outputs, the ER6001-0002 serves as an all-in-one local connection point. Its heavy-duty zinc die-cast housing ensures superior resistance to mechanical stress, moisture, and electromagnetic interference, making it an ideal choice for decentralised control environments across heavy industries.

Features

  • Individually selectable serial interfaces: RS232, RS485, or RS422.
  • Robust 864-byte receive buffer and 128-byte transmit buffer to prevent data loss.
  • Two auxiliary 24 V DC digital inputs and two short-circuit proof digital outputs.
  • Dedicated +5 V DC, 1 A sensor power supply.
  • Standardised M12 connection technology for secure sensor and serial device coupling.
  • Integrated M8 EtherCAT bus interfaces with shielded, screw-type connection.
  • Fully encapsulated housing featuring IP65, IP66, and IP67 protection ratings.

Applications

  • Direct machine-level integration of barcode scanners, printers, and weight indicators.
  • Oil and gas field instrumentation and distributed telemetry systems.
  • Power generation and substation auxiliary device communication.
  • Water and wastewater plant field monitoring and control.

Technical Specifications

ManufacturerPart Number / ModelProduct SeriesProtocolSelectable InterfacesData Transfer RatesCommunication ModeData BufferSensor SupplyDigital InputsDigital OutputsBus InterfaceConnection MethodNominal VoltageCurrent ConsumptionElectrical IsolationOperating TemperatureStorage TemperatureProtection RatingWeight
Beckhoff
ER6001-0002
EtherCAT Box
EtherCAT
RS232, RS485, RS422
300 to 115,200 baud (9600 baud preset, 8N1)
TxD and RxD, full duplex
864 bytes receive buffer, 128 bytes transmit buffer
+5 V DC, 1 A
2 x digital inputs, 24 V DC (10 us filter, 11...30 V "1" signal)
2 x digital outputs, 24 V DC (0.5 A per channel, short-circuit proof)
2 x M8 socket, shielded, screw type
M12 x 1, 5-pin, A-coded
24 V DC (-15% / +20%)
Typically 130 mA + load
500 V
-25 to +60 degC
-40 to +85 degC
IP65, IP66, IP67 (conforms to EN 60529)
Approx. 265 g

Connections and Interfaces

Interface Connection Connector Standard Functional Assignment
EtherCAT Bus Input/Output 2 x M8 Socket, Shielded EtherCAT fieldbus ring communication
Serial & I/O Connections M12 x 1, 5-pin, A-coded Serial transmit/receive data, auxiliary inputs, outputs, and sensor power
Power Supply Feed 1 x M8 Male Socket, 4-pin Control (US) and load voltage (UP) feed
Power Supply Downstream 1 x M8 Female Socket, 4-pin Downstream loop connection for power distribution

Installation Guidelines

  • Mount the module directly to the machine frame or mounting plate. No protective enclosure or cabinet is required thanks to the IP67 housing rating.
  • Ensure all M8 and M12 connectors are securely tightened to the specified torque to maintain the integrity of the environmental seal.
  • Use shielded cabling for all serial communication lines (RS232/RS422/RS485) and ensure the shield is properly terminated at the connector.
  • Keep total serial cable lengths within safe limits: maximum 15 m for RS232 connections, and up to 1000 m for RS422/RS485 networks.

Compliance and Certifications

  • CE
  • UL
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27
Loading product navigation…

Which serial communication standards are supported by the ER6001-0002?

The Beckhoff ER6001-0002 supports RS232, RS422, and RS485 communication. The protocol is individually selectable depending on the connected end device.

What is the protection rating of this module?

The module has an IP65, IP66, and IP67 protection rating according to EN 60529, allowing it to be installed directly on machines without requiring a control cabinet.

What type of sensor supply does the module provide?

The module features an integrated +5 V DC sensor supply rated up to 1 A, which can power connected serial devices and sensors directly.

Are there digital inputs and outputs on the ER6001-0002?

Yes, the module includes 2 digital 24 V DC inputs with a 10 us input filter and 2 short-circuit proof digital 24 V DC outputs rated up to 0.5 A per channel.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...