Description

The Beckhoff IL2300-B518 is a high-performance, decentralized Fieldbus Box designed to establish direct communication between a CANopen network and extension IP67 I/O modules. Engineered for rugged industrial environments, this coupler box eliminates the need for protective control cabinets by offering a fully sealed housing. It supports automatic baud rate detection and efficiently manages decentralized digital and analog signals. The integrated T-connector design simplifies network looping and minimizes cabling complexity on the factory floor.

Features

  • High-Capacity Expansion: Connects up to 120 extension modules, managing up to 128 bytes of input and 128 bytes of output data.
  • Robust Signal Handling: Directs up to 960 digital inputs/outputs and up to 60 analog inputs/outputs.
  • Advanced CANopen Support: Built-in support for up to 16 send and 16 receive Process Data Objects (PDOs), node guarding, life guarding, emergency objects, variable mapping, and store/restore parameters.
  • Flexible Configuration: Easily configurable via the Beckhoff KS2000 software suite or directly through the controller using Service Data Objects (SDOs).
  • Industrial-Grade Housing: Sealed structure certified to IP65/66/67 ratings for complete protection against dust, water jets, and temporary immersion.

Applications

  • Automated assembly lines and material handling systems.
  • Machine tool manufacturing and decentralized robotics controls.
  • Harsh wet-room applications including food and beverage processing.
  • Automotive manufacturing plants and heavy machinery.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model / Part Number IL2300-B518
Fieldbus Interface CANopen
Data Transfer Rates 10 kbaud to 1 Mbaud (automatic detection)
Bus Connection 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) (integrated T-connector)
Control Voltage 24 V DC (-15% / +20%)
Load Voltage Determined by connected I/O type
Power Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Current Consumption 45 mA + sensor current (max. 0.5 A)
Electrical Isolation 500 V (control voltage / fieldbus)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Compatibility Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Connector Type Pin Count Function
M12 Plug (Inlet) 5-pin CANopen fieldbus input
M12 Socket (Outlet) 5-pin CANopen fieldbus downstream loop
M8 Male Socket 4-pin 24 V DC power feed input
M8 Female Socket 4-pin 24 V DC downstream power connection

Installation Guidelines

  • Mounting: Mount in any physical orientation using the integrated mounting holes. Ensure the surface is flat to prevent mechanical stress on the housing.
  • Grounding: Ensure the mounting surface or grounding connection is properly bonded to functional earth to maximize EMC performance and shield integrity.
  • IP Rating Maintenance: Securely tighten all unused M12 and M8 ports with protective caps to maintain the IP65/66/67 rating.
  • Cabling: Keep signal cables and power cables separated when routing to avoid electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the maximum number of I/O modules supported by the Beckhoff IL2300-B518?

The IL2300-B518 supports up to 120 extension modules, handling a maximum of 128 bytes of input data and 128 bytes of output data.

What fieldbus protocol does this coupler box utilize?

This module operates on the CANopen protocol and features automatic baud rate detection from 10 kbaud up to 1 Mbaud.

Does this module require an external enclosure or cabinet?

No, with an IP65/66/67 protection rating, the IL2300-B518 is designed for direct mounting on machines and in harsh environments without an extra control cabinet.

What are the power requirements for the IL2300-B518?

The module requires a 24 V DC control voltage (-15% / +20%) supplied via a 4-pin M8 connector.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...