1 daripada 1

Beckhoff IP2311-B200 Fieldbus Box Digital I/O Module

Beckhoff IP2311-B200 Fieldbus Box Digital I/O Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: IP2311-B200

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Boxes

  • Pembayaran: T/T, Western Union

  • Berat: 250g

  • Dimensi: 30 mm x 210 mm x 26.5 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The Beckhoff IP2311-B200 is a high-performance, distributed Lightbus fieldbus box designed to bridge local digital sensors and actuators with centralized control systems. This ruggedized I/O module integrates 4 digital inputs and 4 digital outputs within a compact, direct-to-machine mountable enclosure, eliminating the need for a separate protective control cabinet.

Operating over the proprietary Beckhoff Lightbus protocol, the module utilizes plastic optical fiber (APF) to guarantee high-speed, noise-immune communication. This fiber-optic medium ensures complete electrical isolation between the communication network and the field power, making the IP2311-B200 exceptionally resilient in high-EMC industrial environments. Designed for direct field deployment, its fully encapsulated housing carries IP65/66/67 ratings, offering robust resistance to dust, moisture, and mechanical vibration.

Features

  • 4 digital inputs (24 V DC) with a 0.2 ms hardware input filter.
  • 4 short-circuit proof digital outputs rated at 0.5 A per channel.
  • Direct Lightbus network integration using plastic optical fiber (APF).
  • Highly secure, interference-free data transmission up to 45 meters between stations.
  • M8 screw-type connectors for standard sensor and actuator connections.
  • Compact and light PA6 polyamide housing with a robust physical design.
  • Comprehensive status LEDs for local diagnostics, channel activity, and optical link status.

Applications

  • Distributed packaging machinery and materials handling systems.
  • Automotive manufacturing lines demanding high EMC immunity.
  • Water and wastewater treatment facilities with high moisture exposure.
  • Machine tool and robotic assembly cells where cabinet space is limited.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model IP2311-B200
Fieldbus Interface Lightbus (2 x fiber-optic sockets for ZS1020-0010 plugs)
Data Transfer Rate 2.5 Mbaud
Transmission Medium APF (plastic) optical fiber (1000 micrometers)
Distance Between Stations Up to 45 m
Number of Channels 4 inputs + 4 outputs
Digital Inputs 24 V DC, -3 to +5 V ("0" signal), 11 to 30 V ("1" signal, 6 mA, Type 2)
Input Filter Time 0.2 ms
Digital Outputs 24 V DC (-15% / +20%), 0.5 A per channel, short-circuit proof
Load Types Supported Ohmic, inductive, lamp load
Control/Supply Voltage 24 V DC (-15% / +20%) via M8 connector
Electrical Isolation Control voltage to fieldbus: Yes
Enclosure Material PA6 (polyamide)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Weight Approx. 250 g

Installation Guidelines

  • Mounting: Mount the unit directly to the machine frame or flat surface using the 2 pre-drilled 3.5 mm mounting holes designed for M3 screws.
  • Fiber-Optic Handling: Maintain the specified minimum bending radius of the APF optical fiber cables to prevent signal attenuation and physical damage.
  • Tightening Torque: Ensure M8 sensor and power connectors are tightened to the recommended torque specification to preserve the IP67 protection rating.
  • Grounding: Connect the functional ground (FE) connection to a low-impedance ground point on the machine to ensure stable internal reference potential.

Compliance and Certifications

  • CE
  • UL
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27

What network interface does the Beckhoff IP2311-B200 use?

The IP2311-B200 connects to the Beckhoff Lightbus system using plastic optical fiber (APF) at a transfer rate of 2.5 Mbaud.

What is the maximum distance supported between two fieldbus boxes?

The maximum distance supported between two individual stations is 45 meters using plastic optical fiber (1000 micrometers).

Can this module be mounted directly onto a machine frame without a cabinet?

Yes. The module features an IP65/IP66/IP67 rated PA6 polyamide housing, making it highly resistant to dust, liquids, and vibration, suitable for direct machine installation.

What are the electrical ratings for the digital outputs?

The digital outputs support 24 V DC with a maximum load current of 0.5 A per channel. Each output channel is individually short-circuit proof.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...