1 daripada 1

Beckhoff IP2330-B310 Fieldbus Box

Beckhoff IP2330-B310 Fieldbus Box

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: IP2330-B310

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Box Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 175 mm x 45 mm x 35 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

For direct installation in the field without protective enclosures, the Beckhoff IP2330-B310 serves as a robust PROFIBUS DP interface block featuring integrated digital I/O channels. By combining 4 digital inputs and 4 digital outputs in a single, high-protection module, this decentralized station minimizes wiring overhead and optimizes signal routing on modern automated production floors. The device communicates directly with the host PLC via a high-speed PROFIBUS DP connection, executing commands with minimal latency and high operational reliability.

Features

  • Direct Field Mounting: IP67-rated housing allows installation outside control cabinets, reducing cabling paths.
  • Digital Input Configuration: 4 channels rated at 24 V DC with a rapid 0.2 ms input filter for precise signal registration.
  • High-Capacity Outputs: 4 digital outputs delivering up to 2 A per channel, fully short-circuit proof.
  • Industrial Standard Connectors: M8 (8 mm) snap-on round connectors for reliable sensor and actuator integration.
  • Compact Form Factor: Small-footprint modular design with integrated mounting holes for direct machine frame attachment.

Applications

  • Decentralized material handling and heavy-duty conveyor systems.
  • Automotive assembly lines requiring localized sensor and actuator distribution.
  • Packaging machinery operating in washdown or high-dust zones.
  • Robotic end-of-arm tooling control interfaces.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff Automation
Model Designation IP2330-B310
Protocol / Interface PROFIBUS DP
Data Transfer Rates Automatic detection up to 12 Mbaud
Digital Inputs 4 channels (24 V DC, filter time 0.2 ms)
Digital Outputs 4 channels (24 V DC, 2 A maximum, short-circuit protected)
Field Connection Type M8 (diameter 8 mm) snap-on connectors
Power Supply Voltage 24 V DC (-15% / +20%)
Operating Temperature Range 0 degC to 55 degC
Storage Temperature Range -25 degC to 85 degC
IP Rating IP65 / IP66 / IP67 (when fully connected and sealed)
Shipping Weight (Calculated) 2.0 kg
Package Dimensions (Calculated) 175 mm x 45 mm x 35 mm

Connections and Interfaces

Connection Pin (M8 Signal) Function / Signal Assignment
Pin 1 Sensor / Actuator Supply (+24 V DC)
Pin 3 Reference Ground (0 V)
Pin 4 Input Signal (Channels 1-4) / Output Signal (Channels 1-4)

Empirical Engineering Insights

Alternative Models & Compatibility

The IP2330-B310 operates as an integrated IP67 equivalent to the coupling of a Beckhoff BK3120/BK3150 PROFIBUS Coupler with KL1404 and KL2404 Bus Terminals. When executing drop-in replacements, ensure that the GSD file installed on the master PROFIBUS controller matches the correct revision level. Older revisions of this Fieldbus Box may have different parameter mappings in hardware configurations; verify whether the GSD file supports the diagnostic structures of newer hardware variants.

Application Pitfalls & Engineering Notes

While individual digital outputs can supply up to 2 A, the cumulative load across all outputs is restricted by the absolute power distribution limit of the module's power feed-in line (typically up to 4 A in series-connected topologies). If driving heavy inductive loads like high-current solenoid valves continuously, mount the module on a metallic plate to aid thermal dissipation and prevent localized thermal shut-down.

Commissioning & Wiring Tips

The PROFIBUS DP address is configured manually via the two rotary switches located behind the screw-down protection cap. Note that the station address cannot be changed dynamically; address modifications only become active upon cycling the system control power (24 V DC). Always ensure the protective screw cap is fully tightened to a minimum of 0.5 Nm after address configuration to maintain the module's IP67 ingress protection rating.

Installation Guidelines

CRITICAL WARNING

Before mounting or servicing this Fieldbus Box, isolate and lock out all 24 V DC control and load power supplies. Ingress of moisture or conductive debris into open, unsealed M8/M12 connectors during installation will cause internal short-circuiting and permanent bus interface failure.

1
Mount the IP2330-B310 onto a flat, vibration-resistant surface using two M3 or M4 screws passing through the integrated mounting slots on the outer edges.
2
Remove the protective cap and configure the target PROFIBUS node address using the dual rotary decimal switches. Reseal the switch cover tightly.
3
Connect the PROFIBUS signal cables to the designated bus interface connectors. Securely tighten all coupled network connections.
4
Install M8 sealing caps on any unused input/output channels to prevent ingress of dirt, cutting oils, or moisture. Apply 24 V DC power and verify system diagnostics.
Loading product navigation…

What is the maximum output current limit for the IP2330-B310?

Each of the 4 digital outputs can switch up to 2 A at 24 V DC. However, the total cumulative current of all outputs must not exceed the maximum rating of the module's power feed line.

How is the PROFIBUS station address configured on this module?

The node address is set manually using two decimal rotary switches located under the protective screw cap. Power must be cycled for address changes to take effect.

Does the IP2330-B310 require a control cabinet for installation?

No, the module features an IP67 rating, meaning it is dust-tight and protected against water immersion, making it suitable for direct machine mounting.

What size connectors are used for the sensor and actuator connections?

The module utilizes standard 8 mm snap-on (M8) round connectors for the digital inputs and outputs.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...