Description

Decentralized installation in harsh environments requires robust interfaces. The Beckhoff IP3112-B528 is a high-performance Fieldbus Box designed to connect digital and analog peripheral signals directly to DeviceNet networks. It functions without requiring a protective control cabinet, utilizing standard M12 and M8 connector interfaces to distribute power and fieldbus communications. The module supports automatic baud rate detection up to 500 kbaud, streamlining commissioning and enhancing diagnostic flexibility via KS2000 configuration software or explicit messaging protocols. Built to withstand challenging plant environments, it provides reliable data transfer and localized control interface distribution.

Features

  • Direct integration into DeviceNet networks with integrated T-connector functionality.
  • Flexible I/O communication modes including polling, cyclic, bit strobe, and change of state (COS).
  • Robust IP65/66/67 housing for decentralized, cabinet-free field installation.
  • Dual-channel M12 fieldbus connections for easy loop-through topology.
  • Efficient M8 power connectors for control voltage feeding and downstream distribution.

Applications

  • Automotive assembly and welding lines.
  • Material handling and conveyor systems.
  • Food and beverage processing plants.
  • Decentralized sensor and actuator networks in high-moisture or dusty environments.

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model IP3112-B528
Fieldbus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated tee-connector
Data Transfer Rates Automatic detection up to 500 kbaud
Data Transfer Medium Shielded copper cable, with power supply, typ. 2 x 2 x 0.25 mm²
Control Voltage Power Supply 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + current consumption of sensors (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: 500 V
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65/66/67 (conforms to EN 60529)
Shipping Weight 2 kg

Connections and Interfaces

Interface Type Connector Description Function
Fieldbus Input 1 x M12 plug, 5-pin DeviceNet incoming communication interface
Fieldbus Output 1 x M12 socket, 5-pin DeviceNet downstream loop-through connection
Power Feed 1 x M8 male socket, 4-pin Control voltage 24 V DC input
Power Downstream 1 x M8 female socket, 4-pin Control voltage daisy-chain to next box

Installation Guidelines

  • Mounting: Mount directly onto flat machine structures using the designated mounting holes. Ensure the surface is free of debris to maintain a secure seal.
  • Wiring: Use shielded copper cabling (typically 2 x 2 x 0.25 mm²) for DeviceNet transmission to preserve signal integrity and avoid EMI.
  • Grounding: Ensure the mounting surface or functional ground connection is correctly bonded to the plant's main ground potential.
  • IP Rating: Ensure all unused M8 and M12 interfaces are fitted with IP67-rated protective caps to maintain the unit's dust and moisture ingress resistance.

Compliance and Certifications

  • CE
  • UL

What communication protocol is supported by the Beckhoff IP3112-B528?

The IP3112-B528 is designed for DeviceNet networks, supporting automatic baud rate detection up to 500 kbaud.

What are the power connections on this Fieldbus Box?

It features a 24 V DC control voltage input via a 4-pin M8 male socket, and a loop-through downstream connection via a 4-pin M8 female socket.

Can this module be mounted outside a control cabinet?

Yes, with an IP65/66/67 rating, this unit is fully protected against dust, low-pressure water jets, and temporary immersion, making it suitable for direct machine mounting.

What configurations are possible for the I/O signals?

Configuration can be completed either via the Beckhoff KS2000 software package or directly through the main PLC controller using explicit messaging.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...