Engineered for decentralized industrial automation, the IP3312-B730 serves as a high-performance Modbus fieldbus box designed to transmit analog and digital peripheral signals under extreme environmental conditions. Utilizing serial communication, this remote I/O module interfaces directly with fieldbus networks without the need for protective control cabinets, reducing cabling complexity and space constraints.

The unit features integrated rotary address selection switches for swift hardware addressing, alongside comprehensive configuration options through the KS2000 commissioning software. Robust M8 and M12 connection technologies guarantee mechanical reliability and secure power distribution, making it an ideal choice for complex, distributed topologies.

Features

  • Supports Modbus RTU and Modbus ASCII communication protocols.
  • Provides wide data transfer rates ranging from 150 to 38,400 baud.
  • Sealed, compact housing offering IP65, IP66, and IP67 protection ratings.
  • Flexible addressing options via mechanical rotary switches or KS2000 software.
  • Galvanic isolation between the control voltage and the fieldbus network.
  • Standardized M12 B-coded fieldbus connection and M8 power supply ports.

Applications

  • Heavy industrial machinery and plant engineering.
  • Distributed sensor-to-controller process topologies.
  • Material handling systems and conveyor networks.
  • Decentralized environmental tracking and automated process lines.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model IP3312-B730
Communication Protocol Modbus RTU / Modbus ASCII
Data Transfer Rates 150, 300, 600, 1200, 2400, 4800, 9600, 19,200, 38,400 baud
Bus Interface 1 x M12 socket, 5-pin, B-coded
Configuration Interface Address selection switches or KS2000 software
Control Voltage 24 V DC (-15% / +20%)
Box Supply Current 45 mA + current consumption of sensors (max. 0.5 A)
Power Connection (Feed) 1 x M8 male connector, 4-pin
Power Connection (Downstream) 1 x M8 female connector, 4-pin
Electrical Isolation Yes (Control voltage / fieldbus)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Weight Approx. 210 g

Connections and Interfaces

Connector / Port Function Type
Bus Interface Modbus RTU / Modbus ASCII Link 1 x M12 socket, 5-pin, B-coded
Power Feed Input Control/Load Voltage (24 V DC) 1 x M8 male socket, 4-pin
Power Downstream Loop-through Power Output 1 x M8 female socket, 4-pin

Installation Guidelines

  • Ensure the installation surface is flat to avoid mechanical stress on the plastic housing when fastening mounting screws.
  • Set the desired Modbus station address via the integrated rotary switches under the protective cap before powering up the device.
  • To maintain IP67 integrity, all unused M8 and M12 connection ports must be sealed with appropriate protective caps.
  • Deploy shielded communication cabling and ground the shield at a single point to mitigate electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
  • EN 61000-6-2 (EMC Immunity)
  • EN 61000-6-4 (EMC Emission)
Loading product navigation…

What communication protocol does the Beckhoff IP3312-B730 support?

The IP3312-B730 supports serial Modbus RTU and Modbus ASCII fieldbus communication protocols.

How do you configure the network address on this fieldbus box?

The station address can be manually configured using the built-in rotary address selection switches or programmatically via the KS2000 software interface.

Can the IP3312-B730 module be mounted without an enclosure?

Yes, it features an IP65/66/67 rating conforming to EN 60529, which allows direct machine installation without a protective control cabinet.

What is the operating temperature range for this module?

The module operates reliably within a temperature range of 0 to +55 degC, and can be stored within -25 to +85 degC.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...