1 daripada 1

Beckhoff IP5109-B520 Fieldbus Box

Beckhoff IP5109-B520 Fieldbus Box

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: IP5109-B520

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Boxes

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 2 x 2 x 0.25 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for decentralized automation architecture, the Beckhoff IP5109-B520 Fieldbus Box establishes reliable distributed I/O connection in harsh manufacturing environments. Operating directly on DeviceNet networks, this robust module eliminates the need for protective control cabinets by providing high ingress protection against dust and liquid exposure. The module features integrated intelligence to detect network transmission speeds dynamically and offers extensive diagnostic functions to minimize plant downtime.

The IP5109-B520 integrates seamless physical layer interfaces using industry-standard M12 and M8 connections. It facilitates flexible communication types, including bit strobe, polling, cyclic, and change-of-state (COS) messaging, ensuring efficient data distribution to high-level controllers. System engineers can configure the module parameters easily through the Beckhoff KS2000 software suite or directly via explicit messaging from the master controller.

Features

  • Cabinet-Free Installation: Rugged design allows direct machine mounting, optimizing wiring paths and reducing installation footprint.
  • Automatic Baud Rate Detection: Automatically senses and adapts to communication speeds up to 500 kbaud.
  • Advanced Diagnostics: Comprehensive diagnostic LEDs provide local visibility into bus status, supply errors, and operational performance.
  • Flexible Communication Protocols: Supports a variety of DeviceNet I/O communication configurations, including polling, bit strobe, cyclic, and change of state.
  • Robust Power Isolation: Provides 500 V electrical isolation between control voltage and fieldbus components.

Applications

  • Automotive assembly and robotic welding lines
  • Material handling and conveyor sortation systems
  • Machine tool and manufacturing line integration
  • Heavy industrial packaging equipment
  • Water and wastewater treatment installations

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model IP5109-B520
Fieldbus Protocol DeviceNet
Data Transfer Rates Automatic detection up to 500 kbaud
Bus Interface Connection 1 x M12 plug, 5-pin
Transmission Medium Shielded copper cable with power supply (typically 2 x 2 x 0.25 mm²)
Control Voltage Power Supply 24 V DC (-15% / +20%)
Power Connection (Feed) 1 x M8 male connector, 4-pin
Power Connection (Downstream) 1 x M8 female connector, 4-pin
Internal Box Supply Current 45 mA + sensor consumption (maximum 0.5 A total)
Electrical Isolation 500 V (control voltage / fieldbus)
Max Station Distance 500 m / 250 m / 100 m (dependent on baud rate and cable type)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals CE, UL
Shipping Weight 2.0 kg

Connections and Interfaces

Connector / Pin Function Description
M12 Bus Pin 1 Shield (drain wire)
M12 Bus Pin 2 V+ (DeviceNet power supply)
M12 Bus Pin 3 V- (DeviceNet power supply reference)
M12 Bus Pin 4 CAN_H
M12 Bus Pin 5 CAN_L
M8 Power Supply Feed Pin 1 Control Voltage +24 V DC (Us)
M8 Power Supply Feed Pin 2 Load Voltage +24 V DC (Up)
M8 Power Supply Feed Pin 3 GNDs (Control Voltage reference)
M8 Power Supply Feed Pin 4 GNDp (Load Voltage reference)

Installation Guidelines

  • Mounting: Attach the box securely using the integrated mounting flanges on a flat, vibration-free surface. Direct metal contact assists with heat dissipation and structural stability.
  • Grounding: Ensure a low-resistance RF grounding connection to the machine chassis via the metallic mounting surfaces or dedicated grounding tabs.
  • Cabling Shielding: Use pre-assembled, shielded DeviceNet cabling to prevent electromagnetic interference from surrounding industrial equipment.
  • Connector Sealing: Tighten all M12 and M8 connectors to their specified torque limits. Cover any unused female sockets with IP67-rated protective caps to maintain the integrity of the enclosure seal.

What fieldbus protocol does the Beckhoff IP5109-B520 use?

The IP5109-B520 operates on the DeviceNet industrial protocol.

How is the communication speed configured on this module?

The module features automatic baud rate detection, allowing it to self-configure on the network up to a maximum transmission speed of 500 kbaud.

What ingress protection rating does this Fieldbus Box offer?

The IP5109-B520 is rated at IP65, IP66, and IP67, protecting internal electronics from heavy dust, water jets, and temporary immersion.

Which software tool is used to parameterize the Beckhoff IP5109-B520?

Configuration can be executed through the Beckhoff KS2000 software interface or directly via the network master utilizing explicit messaging protocols.

What are the power requirements for this device?

The module utilizes a 24 V DC control voltage (with a tolerance range of -15% to +20%) connected via a 4-pin M8 interface.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...