1 daripada 1

BECKHOFF IP6022-B810 Fieldbus Box Serial Interface Module

BECKHOFF IP6022-B810 Fieldbus Box Serial Interface Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: IP6022-B810

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Modules

  • Pembayaran: T/T, Western Union

  • Berat: 210g

  • Dimensi: 30 mm x 175 mm x 26.5 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for robust serial data transmission in demanding industrial environments, the BECKHOFF IP6022-B810 Fieldbus Box serves as a reliable interface for connecting RS422 or RS485 devices directly to fieldbus networks. This compact, decentralized module enables peer-to-peer serial communication, allowing devices such as barcode scanners, operator terminals, and measuring sensors to integrate seamlessly into high-level control systems.

The module supports configurable data transfer rates ranging from 1200 to 115,200 baud, with a factory preset of 9600 baud. To prevent data loss during high-speed operations, the IP6022-B810 features an internal buffer memory comprising a 128-byte receive buffer and a 16-byte transmit buffer. System configuration and parameterization are quickly handled via the KS2000 software tool, providing flexible process image mapping to fit specific application architectures.

Features

  • Supports standard RS422 and RS485 physical layer interfaces for flexible differential serial communication.
  • Adjustable baud rates up to 115,200 baud with hardware-level transmit and receive buffers.
  • Robust IP67-rated encapsulation prevents ingress of water, dust, and particulate matter.
  • Standard M12 and M8 connector interfaces simplify installation and eliminate the need for protective enclosures.
  • Integrated galvanic isolation up to 500 V protects sensitive control electronics from fieldbus loop interference.
  • Compact, space-saving polyamide housing with dual-point mounting designed for direct machine installation.

Applications

  • Factory automation and assembly line serial device integration.
  • Process control systems utilizing long-distance RS422/RS485 instrumentation.
  • Material handling systems for connecting barcode readers and weight scales.
  • Decentralized test and measurement setups requiring high environmental resistance.

Technical Specifications

CategoryTechnical ParameterValue
Manufacturer BECKHOFF IP6022-B810
Interface Type Serial Interface (RS422 / RS485) 1 (peer-to-peer connection)
Data Transfer Rates 1200 baud to 115,200 baud (9600 baud, 8N1 default) Max. 500 m (twisted pair)
Line Impedance 120 Ohm -7 to +12 V (to ground)
Data Buffer 128 bytes receive buffer, 16 bytes transmit buffer 3 x 8-bit user data, 1 x 8-bit control/status (up to 5 x 8-bit user data supported)
Nominal Voltage 24 V DC (-15% / +20%) 45 mA + connected sensor current (max. 0.5 A)
Electrical Isolation 500 V (RS485 to control voltage) 1 x M12 socket, 5-pin, B-coded
Power Ports Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin PA6 (polyamide)
Operating Temperature 0 to +55 degC -25 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529) EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission EN 61000-6-2 / EN 61000-6-4 30 mm x 175 mm x 26.5 mm
Weight approx. 210 g approx. 1.0 kg

Connections and Interfaces

Connection Point Connector Type Function / Pin Assignment
Bus Interface 1 x M12 socket, 5-pin, B-coded Fieldbus connection and network communication
Serial Connection M12, screw type RS422 / RS485 RxD and TxD data channels
Power Feed 1 x M8 male connector, 4-pin Control voltage feed (24 V DC)
Downstream Power 1 x M8 female connector, 4-pin Control voltage loop-through to adjacent modules

Installation Guidelines

  • Mounting: Mount directly to flat surfaces using the two 3.5 mm diameter fixing holes designed for M3 screws.
  • Grounding: Ensure the module is grounded properly through its mounting screws or dedicated functional earth connection to minimize EMC disturbances.
  • Cabling: Use shielded twisted-pair copper cables (minimum 2 x 0.25 mm²) for long-distance serial runs to maintain signal integrity over the maximum 500 m limit.
  • Tightening Torque: Hand-tighten all M12 and M8 connectors to ensure the IP67 sealing integrity without damaging the plastic threads.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the default serial configuration for the IP6022-B810?

The module is preset to 9600 baud, 8 data bits, no parity, and 1 stop bit (8N1), but it can be configured from 1200 to 115,200 baud.

What software is required to configure this Fieldbus Box?

Configuration, mapping, and parameterization of the serial interfaces are done using the Beckhoff KS2000 configuration software.

Does the IP6022-B810 require a protective enclosure?

No, thanks to its IP67-rated polyamide housing and sealed M12/M8 connections, it can be mounted directly onto machines in wet, dusty, or dirty environments.

What is the maximum distance supported for serial data transmission?

Using a high-quality shielded twisted-pair cable, the IP6022-B810 supports RS422/RS485 cable lengths up to a maximum of 500 meters.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...