1 daripada 1

BECKHOFF KL6781 Bus Terminal M-Bus Master

BECKHOFF KL6781 Bus Terminal M-Bus Master

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: KL6781

  • Negara asal:Jerman

  • Jenis Produk: Bus Terminals

  • Pembayaran: T/T, Western Union

  • Berat: 60g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed to facilitate seamless integration of utility metering devices, the Beckhoff KL6781 operates as a single-channel M-Bus master terminal within the standard Beckhoff Bus Terminal system. This module enables direct, bidirectional communication with up to 40 standard M-Bus loads, such as heat, water, electricity, or gas meters, over a single bus segment without requiring external level converters. Operating in master-slave mode via polling, the KL6781 transmits data standard M-Bus physics, enabling consolidated energy management and resource tracking directly from the TwinCAT control environment.

The terminal features a 24-byte process image for inputs and outputs, allowing robust data transfer rates ranging from 300 to 9600 baud. Integration is streamlined through the TwinCAT PLC M-Bus library, which provides specialized function blocks for rapid field configuration. With built-in short-circuit protection and 500 V electrical isolation between the K-bus and the M-Bus physics, the module ensures robust operation and system-wide protection against electrical faults in harsh industrial or commercial environments.

Features

  • Single-Channel Architecture: Dedicated M-Bus interface supporting up to 40 standard M-Bus loads (1.5 mA current consumption per load).
  • Flexible Baud Rates: Configurable data transfer rates from 300 to 9600 baud (default transmission set to 2400 baud).
  • Electrical Isolation: Complete 500 V isolation barrier safeguarding the internal K-bus from the M-Bus network.
  • Integrated Protection: Full short-circuit proof design to prevent module failure during field wiring faults.
  • Software Compatibility: Programmed and configured directly through TwinCAT using official M-Bus PLC function blocks.

Applications

  • Commercial and industrial building automation systems (BAS).
  • Sub-metering networks for monitoring water, gas, steam, and electricity consumption.
  • Energy management systems (EMS) compliant with ISO 5001 standards.
  • District heating stations and utility billing infrastructure.

Technical Specifications

CategoryParameterValue
Administrative Manufacturer Beckhoff Automation
Part Number/Model KL6781
Product Series Bus Terminal System (KL Series)
Communication & Bus Technology M-Bus
Data Transfer Standard M-Bus physics
Number of Channels 1
Maximum Connected Loads 40 standard loads (1.5 mA each)
Data Transfer Rates 300 to 9600 baud (default: 2400 baud)
Bus Access Master-slave mode (polling)
Electrical Data Nominal Voltage 24 V DC (-10% / +8%)
Current Consumption (K-bus) Typically 65 mA
Current Consumption (Power Contacts) Maximum 250 mA
Protection & Safety Short-Circuit Protection Yes
Electrical Isolation 500 V (K-bus / M-Bus)
Process Image Bit Width 24 bytes input / 24 bytes output
Environmental & Mechanical Weight Approx. 60 g
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Standards & Approvals Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Certifications & Marks CE, UL

Connections and Interfaces

Terminal Point Signal/Function Description
1 M+ M-Bus Connection (+)
2 Shield Shielding / Functional Ground
3 +24 V DC External Power Supply (+)
5 M- M-Bus Connection (-)
7 0 V DC External Power Supply (0 V)

Installation Guidelines

  • Mounting: Mount the terminal vertically on standard 35 mm DIN rails (EN 60715) within an IP20-rated enclosure or control cabinet.
  • Wiring: Keep maximum cable lengths on the M-Bus segment below 300 meters. Use shielded twisted-pair (STP) cabling for optimal noise immunity.
  • Grounding: Connect the shield connection point directly to a low-impedance functional ground or DIN rail clamp.
  • Ventilation: Ensure a clearance of at least 30 mm above and below the terminal block to maintain normal operating temperatures between 0 and 55 degC.
Loading product navigation…

What is the primary function of the Beckhoff KL6781?

The Beckhoff KL6781 acts as a single-channel M-Bus master terminal within a Beckhoff Bus Terminal system, enabling direct integration of M-Bus compliant utility meters (water, gas, electricity, heat) without external level converters.

How many M-Bus devices can be connected to the KL6781 terminal?

The KL6781 supports up to 40 standard M-Bus loads, assuming each connected device consumes a standard current of 1.5 mA.

What software is used to configure the KL6781?

Configuration is handled in TwinCAT using the official TwinCAT PLC M-Bus library, which contains dedicated function blocks for communicating with the meters.

Is the KL6781 protected against field wiring faults?

Yes, the module is short-circuit proof and features 500 V electrical isolation between the inner K-bus electronics and the external M-Bus physics.

What is the maximum cable length supported by the M-Bus line on the KL6781?

The terminal supports a maximum M-Bus cable length of up to 300 meters.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...