Description

Processing analog input signals in compact industrial control setups requires reliable, high-density I/O interfaces. The BECKHOFF KS3448 analog input terminal processes up to eight signals in the 0 to 20 mA range with 12-bit resolution. Designed with single-ended technology, this module features a highly compact design form and pluggable wiring levels, easing installation and maintenance in dense control cabinets. It operates directly via the K-bus backplane connection, transmitting digitized process signals to the higher-level automation controller without requiring manual address or hardware configuration.

Features

  • Provides 8 single-ended analog inputs optimized for 0 to 20 mA current loops.
  • Features pluggable wiring levels (KSxxxx series) allowing rapid module exchange without disturbing existing field wiring.
  • Features a compact housing design with high packing density for maximum space utilization in control cabinets.
  • Delivers 12-bit conversion resolution with a fast conversion time of approximately 4 ms.
  • Equipped with 500 V electrical isolation between the K-bus and the process signal voltage.
  • No address or software configuration parameters needed for standard integration.

Applications

  • Industrial process control monitoring analog current loops.
  • Factory automation environments using K-bus controller architectures.
  • Machine manufacturing requiring high-density analog sensor interfaces.
  • Water treatment, environmental monitoring, and building automation installations.

Technical Specifications

Manufacturer BECKHOFF
Part Number KS3448
Module Type Analog Input Bus Terminal
Number of Inputs 8
Signal Current 0...20 mA
Input Technology Single-ended
Internal Resistance < 85 Ohm
Resolution 12 bit
Conversion Time ~ 4 ms
Measuring Error < +/-0.3 % (relative to full scale value)
Surge Voltage Resistance 30 V DC
Electrical Isolation 500 V (K-bus / signal voltage)
Power Supply Via K-bus
Current Consumption K-bus typ. 105 mA
Process Image Bit Width Input: 8 x 16-bit data (8 x 8-bit control/status optional)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Housing Material Polycarbonate
Installation 35 mm DIN rail (EN 60715) with locking mechanism
Wiring Type Spring actuation by screwdriver (pluggable connection level)
Connection Cross-Section Solid/Stranded: 0.08...1.5 mm² (AWG 28...16), Flexible: 0.14...1.5 mm² (AWG 26...16)
Stripping Length 9...10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.055 kg

Installation Guidelines

  • Always isolate all power supplies to the K-bus station and field devices before installing or removing the terminal.
  • Mount the terminal securely onto a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking mechanism engages completely.
  • Maintain clear ventilation space around the terminal stack to prevent localized heat buildup, ensuring operation remains within -25 to +60 degC.
  • To insert field wires, actuate the spring-clamp using a standard terminal screwdriver. Strip wire insulation to a length of 9 to 10 mm.
  • Maintain proper system grounding and shield terminations to protect sensitive analog inputs from electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • DNVGL
Loading product navigation…

What is the primary function of the Beckhoff KS3448?

The Beckhoff KS3448 is an 8-channel analog input bus terminal designed to process 0 to 20 mA current signals using single-ended technology with 12-bit resolution.

What is the main advantage of the KS series compared to the standard KL series?

The KS series (such as the KS3448) features a pluggable wiring design level, which allows the terminal housing to be removed and replaced without disconnecting the pre-wired terminal blocks.

Does the KS3448 require external power supply configuration?

No, the KS3448 is powered directly via the K-bus backplane and does not require manual address or hardware configuration.

What are the environmental operating limits for this module?

The KS3448 operates in temperatures ranging from -25 to +60 degC and with non-condensing relative humidity up to 95%.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...