Description

Generating analog control signals within the Beckhoff I/O system, the KS4031 bus terminal delivers a high-precision, single-channel output ranging from -10 to +10 V. This specialized analog output terminal is built with pluggable wiring levels, simplifying installation and maintenance in dense control cabinets. Operating via the standard K-bus, the module isolates control-side logic from field-level actuator signals up to 500 V, providing superior noise immunity and protection for upstream PLC and industrial PC controllers.

Features

  • Single-channel analog output with a bipolar signal range of -10 V to +10 V.
  • High-resolution 12-bit signal conversion for precise control loop actuation.
  • Pluggable connection technology (KS series design) allowing fast wiring swaps without disconnecting field cables.
  • Complete galvanic isolation of 500 V between the internal K-bus and the field signal.
  • Short-circuit proof output circuitry with a minimum load resistance of 5 kOhm.
  • Diagnostic-friendly interface with optional control and status bytes alongside 16-bit output data in the process image.

Applications

  • Proportional valve control and hydraulic actuator positioning.
  • Speed reference setpoint transmission for variable frequency drives (VFDs).
  • Analog calibration reference in plant engineering and machine manufacturing.
  • Signal conversion in HVAC and building automation control cabinets.

Technical Specifications

Manufacturer Beckhoff
Part Number / Model KS4031
Number of Outputs 1
Signal Voltage -10 to +10 V
Resolution 12 bit
Conversion Time approx. 1.5 ms
Output Error < ±0.1% (relative to end value)
Load Impedance > 5 kOhm (short-circuit proof)
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-bus typ. 75 mA
Bit Width in Process Image Output: 1 x 16-bit data (1 x 8-bit control/status optional)
Connection Technology Pluggable wiring (spring actuation)
Connection Cross-Section Solid/Stranded: 0.08 to 1.5 mm², Fine-wire: 0.14 to 1.5 mm²
Connection Cross-Section AWG AWG 28 to 16
Stripping Length 9 to 10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.085 kg
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Ex Marking II 3 G Ex nA IIC T4 Gc
Approvals and Markings CE, UL, ATEX, DNVGL

Installation Guidelines

  • Mount the terminal on a standard 35 mm DIN rail (conforming to EN 60715) with the locking mechanism engaged.
  • Ensure that electrical power is entirely switched off before connecting or separating the pluggable wiring level.
  • To wire the terminal, actuate the internal spring clamp by pressing a standard flat-blade screwdriver into the release slot.
  • Maintain adequate ventilation clearance above and below the terminal block assembly to comply with the 0 to +55 degC operating envelope.
Loading product navigation…

What is the primary difference between the Beckhoff KL4031 and KS4031?

The KS4031 model features a pluggable wiring level block, allowing the terminal insert to be easily swapped for maintenance without disconnecting the field wiring. The KL4031 model has fixed, non-removable terminal blocks.

What are the output voltage range and signal resolution of the KS4031?

The KS4031 provides a single analog output channel with a signal range of -10 V to +10 V at a conversion resolution of 12 bits.

Does the KS4031 require an external auxiliary power connection?

No, the KS4031 is powered directly through the internal K-bus and does not utilize power contacts.

Is the analog output isolated from the control network?

Yes, the KS4031 features 500 V galvanic electrical isolation between the internal K-bus logic and the field-side analog output circuit.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...