1 daripada 1

Beckhoff KS4494 Bus Terminal Analog Input/Output Module

Beckhoff KS4494 Bus Terminal Analog Input/Output Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: KS4494

  • Negara asal:Jerman

  • Jenis Produk: Analog I/O Modules

  • Pembayaran: T/T, Western Union

  • Berat: 55g

  • Dimensi: 12 mm x 100 mm x 68 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Interfacing field instruments with standard PLC process control systems requires reliable, noise-resistant signal conversion. The Beckhoff KS4494 Bus Terminal integrates physical analog measurement and signal output capabilities into a single, space-saving 12 mm housing module. Operating directly on the standard K-bus backplane, this module provides dual-channel analog inputs and dual-channel analog outputs configured for bipolar -10 to +10 V single-ended signaling. Its distinct pluggable wiring interface enables rapid, error-free wiring field assembly and hot-swappable terminal block replacements without disturbing permanent control cabinet wiring connections.

Key Technical Features

  • Dual-Function Assembly: Houses 2 analog inputs and 2 analog outputs within a unified physical terminal channel structure.
  • Bipolar Voltage Range: Configured for high-precision -10 to +10 V signal ranges, optimizing control for actuators and bi-directional sensors.
  • Pluggable Wiring Level: Tool-less terminal block detachment design simplifies on-site hardware maintenance cycles.
  • Electrical Isolation: Features 500 V galvanic isolation between the internal K-bus and the field-side analog circuits.
  • Efficient Power Sourcing: Low typical current consumption of 70 mA directly from the K-bus internal logical supply line.

Industrial Applications

  • Proportional Valve Control: Standard interfacing for industrial hydraulics and pneumatic positioners requiring bipolar signal drives.
  • Closed-Loop Speed Control: Synchronizing feedback from variable frequency drives (VFDs) and positioning tachometers.
  • OEM Machine Integration: Compact multi-channel signal routing inside standard manufacturing cells with restricted installation footprint.
  • HVAC Damper Actuation: Controlling electronic draft dampers and air handler systems using standard voltage loops.

Technical Specifications Table

Parameter Name Value Specification
Manufacturer Beckhoff Automation GmbH & Co. KG
Model Designation KS4494
Terminal Style Pluggable connection level (KS Series)
Input / Output Count 2 Analog Inputs / 2 Analog Outputs
Analog Signal Type Single-ended, -10 to +10 V
Resolution 12-bit binary
Conversion Time < 2 ms
Output Error Margin < +/-0.3% (relative to full scale)
Internal Input Resistance > 130 kOhm
Output Load Limit > 5 kOhm (short-circuit proof)
Current Draw (K-Bus) typ. 70 mA
Isolation Voltage 500 V (K-bus to signal potential)
Conductor Connection Type Spring-actuated cage clamps
Wire Cross-Section Solid/Stranded: 0.08...1.5 mm2 (AWG 28...16)
Housing Material Polycarbonate, flame-retardant
Operating Temperature 0 to +55 degC
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Module Weight 0.055 kg
Shipping Weight (Calculated) 2.00 kg (with reinforced industrial protective packaging)
Country of Origin Germany

Connections and Interfaces

Terminal Contact Point Signal Assignment Functional Circuit Details
Contact 1 Input 1 (+) Analog input channel 1 signal line (-10 to +10 V)
Contact 2 Output 1 (+) Analog output channel 1 control line (-10 to +10 V)
Contact 3 0 V (Input 1 Ref) Common reference return path for Input 1
Contact 4 0 V (Output 1 Ref) Common reference return path for Output 1
Contact 5 Input 2 (+) Analog input channel 2 signal line (-10 to +10 V)
Contact 6 Output 2 (+) Analog output channel 2 control line (-10 to +10 V)
Contact 7 0 V (Input 2 Ref) Common reference return path for Input 2
Contact 8 0 V (Output 2 Ref) Common reference return path for Output 2

Empirical Engineering Insights

Alternative Models & Compatibility

The KS4494 serves as the direct physical drop-in equivalent to the standard Beckhoff KL4494 bus terminal block. While the KL4494 utilizes static cage clamps, the KS4494 integrates a split, multi-pin pluggable front interface. Both terminals share the exact same TwinCAT XML device description (GSDML/EDS configurations) and use identical 2 x 16-bit input and 2 x 16-bit output process images, requiring zero modifications to controller logic during hardware modernization programs.

Application Pitfalls & Engineering Notes

Because this module utilizes a single-ended signal configuration with internal reference ground links, field instrumentation sharing common paths can introduce signal skewing. When routing cables across long industrial enclosures, ground loops might compromise the 12-bit ADC digitization stability. Ensure external transmitters and current loads share a zero-volt potential close to the terminal group or deploy isolation barriers if signal noise spikes are detected in TwinCAT Scope.

Commissioning & Wiring Tips

Use a standard 3.0 mm flat-head terminal screwdriver to actuate the spring contacts. We highly recommend using shielded twisted pair (STP) cabling for all -10 to +10 V connections, grounding the shield exclusively at the cabinet side's main grounding busbar. During initial startup, map variables within TwinCAT to monitor the raw register values, where standard hexadecimal limits represent the bipolar physical boundaries.

Installation Guidelines

CRITICAL SYSTEM INTEGRITY WARNING

Always isolate all field-side and logic-side power supplies before mounting, dismounting, or inserting/extracting the pluggable terminal blocks. Failure to de-energize the K-bus backplane can lead to physical arc damage or disrupt adjacent backplane communications, triggering a bus controller watchdog shutdown.

1
Align the slide-and-key guide mechanism on the side panel of the KS4494 with the adjacent bus terminal of your installation layout.
2
Press down firmly on the DIN rail carrier until the lock clip securely engages with the 35 mm mounting rail (conforming to EN 60715).
3
Insert the pre-wired pluggable wiring block into the front socket interface of the module until it clicks securely into place.
Loading product navigation…

What is the key functional difference between the Beckhoff KL4494 and the KS4494?

The primary difference lies in the wiring interface. The KL4494 features standard fixed tension clamp connections, while the KS4494 integrates a pluggable terminal design that allows the active module body to be swapped without disconnecting the field-level wiring.

How do the single-ended analog input connections on the KS4494 function?

The module utilizes a common internal 0 V potential reference across the input and output channels. Unbalanced signals with potential reference differences between connected field devices should be avoided to prevent noise and grounding loops.

Can the inputs and outputs handle typical 0 to 10 V voltage ranges?

Yes, although the module is engineered for a full bipolar -10 V to +10 V signal range, it is backwards compatible and can process standard unipolar 0 to +10 V ranges through software calibration in TwinCAT.

Is the analog output circuitry protected against external short-circuits?

Yes, the analog outputs are designed to be short-circuit proof with a load resistance requirement of greater than 5 kOhms to prevent damage from faulty wiring configurations.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...