Beckhoff ZB7210-0100 EtherCAT P Drag-Chain Cable

Beckhoff ZB7210-0100 EtherCAT P Drag-Chain Cable

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: ZB7210-0100

  • Negara asal:Jerman

  • Jenis Produk: EtherCAT P Cables

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 1 x 4 x 0.34 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for demanding dynamic industrial environments, the Beckhoff ZB7210-0100 raw cable integrates high-speed EtherCAT P communication and robust auxiliary power distribution within a single wear-resistant sheath. This cable features a high-flexibility construction tailored specifically for continuous motion in drag chains and moving machine elements. By combining four Ethernet communication cores with three high-capacity power conductors, it eliminates the need for separate signal and power lines, reducing installation footprint, labor costs, and cable carrier weight in decentralized control architectures.

Features

  • Optimized for Motion: Engineered specifically for drag-chain routing with reliable torsion and bending endurance.
  • Rugged PUR Sheath: Polyurethane (PUR) outer jacket provides exceptional resistance to mineral oils, synthetic coolants, and mechanical abrasion.
  • High-Visibility Identification: Deep black jacket (similar to RAL 9005) with a distinctive red stripe (similar to RAL 3020) for instantaneous identification as an EtherCAT P line.
  • Dual-Function Core Design: Integrates a 4-core Ethernet star quad with three large-cross-section power conductors to service standard 24V DC logic and peripheral power.

Applications

  • Decentralized I/O stations utilizing Beckhoff EtherCAT P EP-series box modules.
  • Multi-axis robotic arms, gantries, and automated pick-and-place machinery.
  • Dynamic material handling, continuous-flex packaging lines, and conveyor tracking systems.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Model/Article Number ZB7210-0100
Cable Type EtherCAT P (Combined communication & power)
Overall Shielding No overall shield
Ethernet Cross Section 1 x 4 x 0.34 mm2 (AWG 22)
Power Cross Section 3 x 2.5 mm2 (approx. AWG 14)
Jacket Material PUR (Polyurethane)
Outer Cable Diameter 11.1 mm (+/- 0.2 mm)
Jacket Color Black (RAL 9005) with red stripe (RAL 3020)
Mechanical Use Case Drag-chain suitable / Continuous flexing
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Conductor Group Wire Properties Primary Function
Ethernet Core (Star Quad) 4 x 0.34 mm2 (AWG 22) EtherCAT P signal transmission (Tx+/Rx+/Tx-/Rx-) with integrated 24V supply on signal lines (Us/Up)
Power Core 3 x 2.5 mm2 (AWG 14) Auxiliary power lines for peripheral loads, actuators, and high-current hardware branches

Empirical Engineering Insights

Alternative Models & Compatibility

The ZB7210-0100 is supplied as raw bulk cable. It is fully compatible with standard Beckhoff B23 field-installable connectors. When selecting connectors, ensure you source B23 Series EtherCAT P rated connectors to maintain correct spacing and pin alignment for the AWG 14 power and AWG 22 communication lines. Do not use standard EtherCAT (non-P) connectors, as standard EtherCAT does not support integrated power lines on the communication cores.

Application Pitfalls & Engineering Notes

While the outer PUR jacket is exceptionally tough, avoid exceeding the maximum physical bending limits inside a drag chain. Torsional stress should be eliminated by ensuring the cable is laid flat without twists when first wound into the carrier. Running this cable adjacent to unshielded high-voltage AC motor drives in the same tray should be done with care; although the EtherCAT signal is highly robust, physical separation from noisy motor leads prevents coupling into the unshielded power conductors inside this cable run.

Commissioning & Wiring Tips

When stripping the outer jacket to terminate into a field-mountable connector, use specialized outer jacket strip tools calibrated for 11.1 mm outer diameters to prevent nicking the thin insulation on the 0.34 mm2 communication cores. Ensure that the red identification stripe remains visible outside the cable gland of your connector to allow field technicians to distinguish the safe EtherCAT P network run from standard Ethernet lines at a glance.

Installation Guidelines

CRITICAL WARNING: Prior to terminating, pulling, or adjusting cables, verify that all power sources supplying both communication (Us) and peripheral (Up) networks are fully de-energized. Do not plug or unplug the terminations of this cable under load, as arcing can damage internal contacts and delicate downstream PLC electronics.
1

Unroll the cable directly from the drum before installation. Do not pull the cable over the side of the spool, as this introduces structural twisting that degrades drag-chain life expectancy.

2

Lay the cable loosely in the drag chain. Ensure it occupies no more than 60 percent of the internal cross-section of the carrier cavity to allow lateral movement during high-flexion runs.

3

Secure both ends of the cable with robust strain relief brackets outside the moving sections of the drag chain. Clamp only the outer PUR jacket without compressing the internal cores.

Loading product navigation…

What is the mechanical advantage of the PUR jacket on this cable?

The Polyurethane (PUR) jacket offers high resistance to oil, abrasion, tearing, and micro-organisms, making it excellent for continuous dynamic flexing in industrial drag-chain applications.

Does this cable have an overall shield?

No, this specific configuration has no overall shield surrounding all the internal conductors, which increases flexibility and reduces weight for designated motion paths.

What is the difference between standard EtherCAT and EtherCAT P cabling?

EtherCAT P combines EtherCAT industrial communication and system/field power (Us and Up) into a single physical cable, distinguished by its black jacket with a red stripe.

Can I terminate this cable with standard RJ45 connectors?

No, because the cable contains large 2.5 mm2 power conductors, standard RJ45 connectors are physically incompatible. You must use specialized EtherCAT P connectors such as the B23 series.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...