1 daripada 3

Bently Nevada 190501-01-99-01 Velomitor CT Transduser Halaju

Bently Nevada 190501-01-99-01 Velomitor CT Transduser Halaju

Hanya 5 item tinggal dalam stok
  • Pengilang: Bently Nevada

  • No. Produk: 190501-01-99-01

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Penukar Halaju Velomitor CT

  • Kod bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 297g

  • Dimensi: 33 mm x 33 mm x 82 mm (H x W x D)

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Deskripsi

190501-01-99-01 Velomitor CT Velocity Transducer adalah sensor piezo-kecepatan frekuensi rendah yang direka khusus untuk mengukur kelajuan getaran casing pada pemasangan kipas menara penyejuk dan penukar haba yang disejukkan oleh udara. Konfigurasi ini menampilkan 3/8-in 24 ke 3/8-in 24 stud (Pilihan 01) untuk pemasangan dan menggunakan antara muka sambungan MIL-C-5015 (Pilihan 99) dengan kabel sepanjang 32 kaki yang disertakan, sesuai untuk sistem yang memerlukan integrasi sambungan bukan standard. Transduser ini berkesan mengukur amplitud getaran pada frekuensi rendah, termasuk yang dihasilkan oleh motor kipas dan pengurang kelajuan, biasanya beroperasi pada atau di atas 90 rpm.

Rangkaian 190501 direka untuk memberikan pengukuran casing yang boleh dipercayai dengan menukar getaran mekanikal kepada isyarat voltan yang sepadan. Unit ini dikonfigurasikan dengan Pilihan 01 untuk kelulusan agensi, termasuk sijil CSA, ATEX, dan IECEx untuk aplikasi kawasan berbahaya. Pemasangan yang betul pada rumah galas atau casing mesin adalah penting untuk mengekalkan tindak balas frekuensi dan mengelakkan penghasilan isyarat palsu.

Ciri-ciri

  • Pemasangan (Pilihan 01): Termasuk stud 3/8-in 24 ke 3/8-in 24 untuk pemasangan mekanikal standard.
  • Sambungan (Pilihan 99): Antara muka sambungan MIL-C-5015 dengan kabel sepanjang 32 kaki yang disertakan dari kilang.
  • Kelulusan Agensi (Pilihan 01): Disahkan untuk persekitaran berbahaya, termasuk Kelas I, Bahagian 1 dan Zon 0/1.
  • Tindak Balas Frekuensi: Dioptimumkan untuk pemantauan frekuensi rendah, 1.5 Hz hingga 1.0 kHz (+/- 3.0 dB).
  • Sensitiviti: 100 mV/in/s (3.94 mV/mm/s) +/- 5% pada 100 Hz.
  • Reka Bentuk: Sarung keluli tahan karat 316L untuk perlindungan persekitaran dan ketahanan.

Aplikasi

  • Pemantauan getaran pemasangan kipas menara penyejuk
  • Pemantauan kipas penukar haba yang disejukkan oleh udara
  • Getaran casing mesin berputar kelajuan rendah (100 hingga 300 rpm biasa)
  • Pemantauan getaran kawasan berbahaya (Kelas I, Div 1 / Zon 0/1)

Maklumat Pesanan

Pilihan Kod Deskripsi
Nombor Bahagian Boleh Dipesan 190501-01-99-01 Velomitor CT Velocity Transducer
A - Perkakasan Pemasangan 01 Stud 3/8-in 24 ke 3/8-in 24
B - Sambungan 99 Unit dengan kabel sepanjang 32 kaki yang disertakan
C - Kelulusan Agensi 01 CSA/NRTL/C, ATEX/IECEX/CSA

Spesifikasi Teknikal

Pengilang Bently Nevada (Baker Hughes)
Sensitiviti 100 mV/in/s (3.94 mV/mm/s) +/- 5%
Tindak Balas Frekuensi 1.5 Hz hingga 1.0 kHz (+/- 3.0 dB)
Suhu Operasi -40 degC hingga +85 degC
Bahan Sarung Keluli tahan karat 316L
Penyambung MIL-C-5015, 2-pin
Berat < 297 g
Tork Pemasangan 4.5 N-m +/- 0.6 N-m
Had Kelembapan 100% kondensasi, tidak terendam

Garis Panduan Pemasangan

  • Pasang transduser terus pada rumah galas atau casing mesin untuk pengukuran kelajuan yang tepat.
  • Ketatkan stud pemasangan kepada 4.5 N-m (40 in-lbf) +/- 5 in-lbf.
  • Pastikan kabel dipasang dengan kemas untuk mengelakkan tekanan pada penyambung MIL-C-5015.
  • Untuk pemasangan kawasan berbahaya, patuhi keperluan pendawaian mengikut lukisan 167536 dan kod elektrik tempatan.

Pematuhan dan Sijil

  • ATEX/IECEx: Ex ia IIC T3 Ga / Ex ec IIC T3 Gc / Ex tc IIIC T200C Dc
  • Kawasan Berbahaya: Kelas I, Div 1, Kumpulan A, B, C, D; Kelas II, Kumpulan E, F, G; Kelas III
  • Arahan: CE, RoHS, Arahan EMC 2014/30/EU
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 190501-01-99-01 Velomitor CT Transduser Halaju

What is the primary application for the 190501 Velomitor CT?

The 190501 Velomitor CT is specifically designed for measuring casing vibration velocity on cooling tower and air-cooled heat-exchanger fans that operate at low speeds, typically at or above 90 rpm.

What does the '99' option code indicate for this SKU?

The '99' option in the connection segment indicates that the unit is supplied with an included 32-foot cable, pre-configured with a MIL-C-5015 connector.

Can this transducer be installed in hazardous areas?

Yes, this specific configuration (Agency Approval Option 01) is certified for use in hazardous areas, including ATEX, IECEx, and CSA Class I, Division 1 / Zone 0/1 environments.

What is the recommended mounting torque for this sensor?

The recommended mounting torque for the 190501 Velomitor CT is 4.5 N-m +/- 0.6 N-m (40 in-lbf +/- 5 in-lbf).

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Mengapa Data Penyelenggaraan Penting untuk Kebolehpercayaan Industri

Data penyelenggaraan menghubungkan pesanan kerja, isyarat sensor, sejarah aset, kos, dan pengetahuan juruteknik. Digunakan dengan baik, ia meningkatkan perancangan, kebolehpercayaan, penyelenggaraan...

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...