Description

Option 05 (5.0 mm unthreaded length), Option 30 (30 mm case length), Option 50 (5.0 m total length), and Option 12 (ClickLoc connector with FluidLoc cable) specify this 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe with China hazardous area approvals (-CN).

This reverse-mount probe configuration features M10 x 1 metric threads and is engineered for installation inside machine casings or sleeves where standard forward-mounting is physically restricted. Unlike standard probes utilizing standard coaxial cables, this variant integrates a FluidLoc cable (Option 12), which provides a block against oil or process fluids from migrating along the cable via capillary action. Additionally, the 5.0-meter integral probe cable (Option 50) matches perfectly with a 5-meter 3300 XL Proximitor sensor, eliminating the need for an intermediate extension cable in specific turbine housing mounting layouts.

Features

  • Option 05 unthreaded length provides a precise 5.0 mm (0.20 in) clearance at the mounting base.
  • Option 30 case length specifies a 30 mm (1.2 in) total metric threaded housing of M10 x 1 thread size.
  • Option 50 designates a 5.0-meter (16.4 feet) total integral probe cable length for direct connection to 5-meter Proximitor systems.
  • Option 12 incorporates a FluidLoc cable and a miniature coaxial ClickLoc connector to halt oil leakage along the cable core.
  • Suffix -CN certifies the assembly for China hazardous area environments under NEPSI and CCC regulations.
  • Polyphenylene sulfide (PPS) probe tip provides chemical and thermal isolation up to 177 degC (350 degF).
  • AISI 303 or 304 stainless steel case offers structural protection in high-vibration machinery casings.

Applications

  • Axial position and radial vibration measurements in heavy industrial rotating machinery.
  • High-pressure casing penetration where FluidLoc technology prevents lubricating oil migration.
  • Reverse-mount turbine bearing housing installations with limited external access.
  • Petrochemical and power generation installations in China requiring NEPSI and CCC hazardous area compliance.

Ordering Information

Option Segment Code Value Meaning / Description
Orderable Part Number 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe (M10 x 1 threads)
Segment A (Unthreaded Length) 05 5.0 mm (0.20 in) unthreaded length
Segment B (Overall Case Length) 30 30 mm (1.2 in) case length
Segment C (Total Length) 50 5.0 meters (16.4 feet) total length
Segment D (Connector & Cable) 12 Miniature ClickLoc coaxial connector, FluidLoc cable
Suffix -CN (Agency Approval) -CN China hazardous area approval package (NEPSI + CCC)

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Part Number 330106-05-30-50-12-CN
Probe Tip Diameter 8.0 mm (0.31 in)
Thread Size M10 x 1 (Metric)
Unthreaded Length 5.0 mm (0.20 in)
Overall Case Length 30 mm (1.2 in)
Total Probe Length 5.0 meters (16.4 feet)
Cable Type 75 Ohm FluidLoc triaxial cable
Connector Type Miniature ClickLoc coaxial connector
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 303 or 304 stainless steel (SST)
Operating Temperature (Probe) -52 degC to +177 degC (-62 degF to +350 degF)
Maximum Rated Pressure Designed to seal differential pressure between tip and case
Tensile Strength (Maximum Rated) 330 N (75 lbf) probe case to probe lead; 270 N (60 lbf) lead to connectors
Minimum Cable Bend Radius 25.4 mm (1.0 in)
Connector Torque (Maximum) 0.565 Nm (5 in-lbf)
Probe Case Torque (Maximum) 22.6 Nm (200 in-lbf) for reverse-mount probes
Nominal DC Resistance 7.45 to 9.87 Ohms depending on overall circuit (8.73 Ohms typical for 5.0m probe)
Dimensions 250 mm x 250 mm x 50 mm (H x W x D) (coiled probe envelope)
Weight 1.65 kg (3.64 lb)

Installation Guidelines

  • Reverse-mount probes are installed from the inside or inside a dedicated probe sleeve/housing.
  • Observe the minimum permissible cable bend radius of 25.4 mm (1.0 in) to prevent internal conductor damage.
  • Hand-tighten the ClickLoc coaxial connector to avoid stripping gold-plated surfaces; do not exceed 0.565 Nm (5 in-lbf).
  • Mount the probe-to-extension cable junction in a clean dry location; avoid exposing connectors directly to aggressive turbine lubricating oil without a protective sleeve.
  • Ensure the probe case torque does not exceed 22.6 Nm (200 in-lbf) during reverse-mount seating in the M10 x 1 threaded housing.

Compliance and Certifications

  • NEPSI (National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation)
  • CCC (China Compulsory Certification)
  • Hazardous area explosion-proof markings as specified by the -CN package
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe

What does the "12" connector option represent on this probe?

The Option 12 code specifies a miniature ClickLoc coaxial connector paired with a FluidLoc cable. This specialized cable prevents machinery oil or process fluids from leaking or migrating along the cable core via capillary action.

Why is this model termed a reverse-mount probe?

The reverse-mount configuration (model 330106) has the threads positioned near the probe tip instead of the back of the case. This allows the probe to be installed through the inside of machine housings or sleeves where standard external thread mounting is not feasible.

Can this 5.0-meter probe be used with a 9-meter Proximitor sensor?

No, 5.0-meter proximity probes are engineered specifically for use with a 5-meter Proximitor sensor only. Operating this probe with a 9-meter sensor will disrupt system calibration and cause incorrect output.

What certifications does the -CN suffix provide?

The -CN suffix designates the China hazardous area approval package, which includes official NEPSI explosion-proof certification and CCC (China Compulsory Certification) markings for industrial installations in China.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diilhamkan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang dikuasakan...