Fully threaded M14 x 1.5 metric steel probe body (Option 000) with a 40 mm overall case length (Option 040) and 1.0 m total length (Option 10) — 330703-000-040-10-12-00. This unarmored 3300 XL 11 mm Proximity Probe incorporates a FluidLoc cable (Option 12) featuring a miniature ClickLoc coaxial connector. The specialized FluidLoc internal construction blocks oil and other liquids from migrating along the interior of the probe cable, establishing a secure seal for harsh industrial environments where fluid exposure is a concern.

Designed for non-contacting vibration and displacement measurement, this metric probe is an essential component of the 3300 XL 11 mm Proximity Transducer System. In contrast to standard non-sealed cable options, the FluidLoc design prevents process fluid bypass, making it highly effective for direct-exposure installations. This configuration requires no special hazardous area agency approvals (Option 00) and connects with standard 3300 XL 11 mm extension cables and Proximitor Sensors to achieve a 4.0 mm linear range on industrial rotating machinery.

Features

  • FluidLoc cable option (Option 12) prevents process fluids and oil from leaking through the cable interior.
  • M14 x 1.5 metric threaded probe body (without armor) for direct mounting into metric tapped machine cases.
  • 0 mm unthreaded length (Option 000) maximizes thread engagement across the 40 mm case length.
  • 1.0 m total length (Option 10) for standard system routing to a matching extension cable.
  • Gold-plated brass ClickLoc coaxial connector ensures a secure, vibration-proof connection.
  • No agency approval (Option 00) for general-purpose, non-hazardous area applications.

Applications

  • Steam and gas turbine rotor axial position monitoring
  • Thrust position measurements where extended linear range is required
  • Differential expansion monitoring on steam turbine casings
  • Rod drop and rod position measurements in reciprocating compressors
  • Speed sensing and Keyphasor phase reference signal generation

Ordering Information

Option Code on This SKU Description
Orderable Part Number 330703-000-040-10-12-00 3300 XL 11 mm Proximity Probe, M14 x 1.5 thread, without armor
A - Unthreaded Length Option 000 0 mm unthreaded length
B - Overall Case Length Option 040 40 mm overall case length
C - Total Length Option 10 1.0 meter (3.3 feet)
D - Connector and Cable-Type Option 12 Miniature coaxial ClickLoc connector, FluidLoc cable
E - Agency Approval Option 00 Not required

Technical Specifications

Manufacturer Bently Nevada
Part Number/Model 330703-000-040-10-12-00
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 304 stainless steel (SST)
Thread Size M14 x 1.5 metric thread
Armor Unarmored (without armor)
Cable Type 75 Ohm triaxial, FluidLoc moisture/oil-blocking cable
Connector Type Gold-plated brass miniature ClickLoc coaxial connector
System Output Sensitivity 3.94 V/mm (100 mV/mil) when paired with compatible 3300 XL 11 mm system
Linear Range 4.0 mm (160 mils), from approximately 0.5 mm to 4.5 mm (20 to 180 mils) from target
Recommended Gap Setting 2.5 mm (100 mils)
Operating and Storage Temperature (Probe) -52 degC to +177 degC (-62 degF to +351 degF)
Probe Case Torque (Maximum Rated) 63.3 N-m (560 in-lb)
Probe Case Torque (Recommended) 21.1 N-m (187 in-lb)
Tensile Strength (Maximum Rated) 330 N (75 pounds) probe case to probe lead
Relative Humidity 100% condensing, non-submersible when connectors are protected
Minimum Bend Radius 25.4 mm (1.0 in)

Installation Guidelines

  • Probe Gap Setting: Adjust the physical probe-to-target gap using a digital voltmeter connected to the Proximitor Sensor output. The recommended nominal gap is 2.5 mm (100 mils), which corresponds to approximately -10 Vdc output.
  • Thread Engagement: Do not exceed the maximum rated thread engagement length of 21 mm for M14 x 1.5 cases to prevent binding during installation.
  • Connector Torque: Connectors should be finger-tight. The maximum recommended torque is 0.565 N-m (5 in-lb) for mating coaxial connectors.
  • Cable Routing: Ensure the minimum bend radius of 25.4 mm (1.0 in) is maintained to protect the coaxial cable from damage.
  • Moisture Protection: Ensure connectors are adequately protected to achieve up to 100% relative humidity sealing.

Compliance and Certifications

  • European Community Directive: EMC Directive 2014/30/EU
  • Standards: EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions) for Industrial Environments
  • RoHS: European Community Directive 2011/65/EU
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330703-000-040-10-12-00 3300 XL 11 mm Proximity Probe

What does the "FluidLoc" cable option (Option 12) do on this probe?

The FluidLoc option features a specialized internal probe cable construction that prevents oil, moisture, and other process fluids from leaking or migrating through the interior of the cable.

What are the thread and armor specifications for this configuration?

This configuration features an M14 x 1.5 metric thread with 0 mm unthreaded length (fully threaded 40 mm case length) and does not include stainless steel armor.

What is the recommended probe gap and measuring range?

The probe has a linear measuring range of 4.0 mm (160 mils), starting at approximately 0.5 mm from the target. The recommended nominal gap setting is 2.5 mm (100 mils).

Does this specific probe configuration come with hazardous area approvals?

No, this specific part number ends with Option 00, indicating that hazardous area approvals are not required for this general-purpose installation.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diilhamkan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang dikuasakan...