Description

To manage complex industrial processes, the AHCPU530-RS2 serves as a highly reliable main processing unit within the Delta AH Series PLC system. This high-density CPU module delivers swift execution speeds of 0.1 microseconds for basic LD instructions, enabling rapid logic processing and real-time system coordination in demanding automation environments. Equipped with built-in multi-mode RS-232/422/485 ports and a Mini-USB programming interface, this controller facilitates seamless integration with human-machine interfaces, variable frequency drives, and supervisory control networks.

The system architecture supports a large control scale, handling up to 4,352 local I/O points and expanding across up to 7 extension backplanes. Program storage is secured via a 256K steps (1MB) program capacity, complemented by robust data registers and native support for multiple IEC 61131-3 programming languages, including Ladder Diagram (LD), Sequential Function Chart (SFC), Function Block Diagram (FBD), Instruction List (IL), and Structured Text (ST).

Features

  • High-speed logic processing: LD instruction execution at 0.1 microseconds (1K steps in 0.3 ms).
  • Substantial memory allocation: 256K steps program memory and 64K words data registers.
  • Integrated dual serial communication: Two multi-mode RS-232/422/485 ports supporting MODBUS RTU and ASCII protocols.
  • Broad system expansion: Supports up to 7 extension backplanes and a maximum of 4,352 local I/O points.
  • Built-in SD card interface: Supports standard SD cards up to 2GB for diagnostic logs and data backups.
  • Battery-free design: Built-in Real-Time Clock (RTC) function retains time for up to 30 days post power-down without a backup battery.

Applications

  • Power generation and distribution automation
  • Water and wastewater treatment infrastructure
  • HVAC and environmental control systems
  • Material handling, logistics, and high-speed assembly lines
  • Chemical and process manufacturing control

Technical Specifications

Manufacturer Delta Electronics
Model AHCPU530-RS2
Product Series AH Series
Module Type CPU Module
Program Capacity 256K steps (1 MB)
Local I/O Capacity 4,352 points
Data Register D / L / B 64K / 64K / 4096K words
Function Blocks Max. 1024
Extension Backplane Support Up to 7 backplanes
Power Consumption 2W (Internal)
Execution Speed 0.1 microseconds (LD instruction)
Built-in Ports 2 x RS-232/422/485, 1 x Mini-USB programming port
External Storage Support SD card slot (Max. 2 GB)
Timers and Counters 2048
Interrupts 256 (Timed, I/O, External, Low voltage, Communication)
Programming Languages LD, SFC, FBD, IL, ST
Dimensions (H x W x D) 110 mm x 40 mm x 103 mm
Shipping Weight 2 kg

Connections and Interfaces

Port / Interface Functional Description
COM1 / COM2 (Multi-mode) RS-232 (up to 115.2 kbps) / RS-422 and RS-485 (up to 921.6 kbps)
Mini-USB Dedicated local programming, configuration, and diagnostics interface
SD Slot Memory card expansion up to 2 GB for firmware, programs, or logs

Installation Guidelines

  • Backplane Installation: Mount the module securely onto the main AH series backplane, checking that the top and bottom latch connectors are fully locked.
  • Grounding: Connect the backplane's functional ground terminal directly to a clean, noise-free system earth.
  • Wiring: Route the RS-485 and communication lines away from high-voltage motor cables to prevent electromagnetic interference. Shielded cables are highly recommended.
  • Thermal Clearance: Maintain a minimum of 50 mm passive airflow gap above and below the CPU unit.
Loading product navigation…

What is the maximum local I/O capacity supported by the AHCPU530-RS2?

The AHCPU530-RS2 CPU module supports a maximum local I/O capacity of up to 4,352 points when fully expanded.

Does this CPU module require a backup battery for real-time clock (RTC) retention?

No battery is required. The AHCPU530-RS2 features a battery-free design with a built-in RTC function that can retain time and system states for up to 30 days after power-off.

What programming languages are compatible with this AH Series controller?

The module is compatible with five IEC 61131-3 standard languages: Ladder Diagram (LD), Sequential Function Chart (SFC), Function Block Diagram (FBD), Instruction List (IL), and Structured Text (ST).

What is the execution speed of the AHCPU530-RS2 processor?

The program execution speed is 0.1 microseconds for basic LD instructions, processing approximately 1K steps in 0.3 milliseconds.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...