1 daripada 1

Delta Electronics VFD45AMS43ANSAA MS300 Series Variable Frequency Drive

Delta Electronics VFD45AMS43ANSAA MS300 Series Variable Frequency Drive

Hanya 10 item tinggal dalam stok
  • Pengilang: Delta Electronics

  • No. Produk: VFD45AMS43ANSAA

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 8000g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered to deliver high-performance vector control in complex industrial environments, the Delta Electronics VFD45AMS43ANSAA belongs to the compact, versatile MS300 Series micro-drive family. This drive is optimized for demanding applications requiring robust motor control, featuring a 45A rated output current under Heavy Duty operation and an integrated Safe Torque Off (STO) safety function to meet strict global safety requirements. Built with a space-saving design, it seamlessly supports both induction and permanent magnet motors while operating on a 460V 3-phase input power supply.

Key Features

  • Heavy Duty Overload Capacity: Rated for a 45A output current with an overload tolerance of 150% for 60 seconds.
  • Advanced Safety Integration: Built-in Safe Torque Off (STO) complying with EN ISO 13849-1 Cat 3 PL e and IEC 61508 SIL3.
  • Flexible Motor Support: Dual-control capability allows open-loop control of both traditional Induction Motors (IM) and high-efficiency Permanent Magnet (PM) synchronous motors.
  • Compact Book-Shelf Design: Standard IP20 housing allows side-by-side DIN-rail mounting to maximize control cabinet space.
  • Built-in USB Port: Facilitates direct connection to PCs for rapid configuration, commissioning, and diagnostic monitoring using Delta software.

Applications

  • High-torque machine tool spindles and metal processing hardware.
  • Industrial packaging machinery, sorting conveyors, and logistics handling.
  • Heavy-duty pumping systems and high-volume HVAC air handling units.
  • Precision textile production systems and automated woodworking machinery.

Technical Specifications

Parameter Value
Manufacturer Delta Electronics
Model Number VFD45AMS43ANSAA
Series MS300 (Standard Micro Drive)
Rated Input Voltage 460V AC (3-Phase)
Rated Output Current 45A (Heavy Duty, 150% overload for 60 seconds)
Enclosure Rating IP20 (Standard Housing)
Integrated EMC Filter None (No Function Code: N)
Safety Standard Built-in STO (SIL3 / PL e)
Control Modes V/F, SVC (Sensorless Vector Control) for both IM and PM
Physical Unit Weight 6.25 kg
Shipping Weight (Calculated) 8.00 kg

Connections and Interfaces

Terminal Block Designation Functional Assignment / Description
R/L1 - S/L2 - T/L3 3-Phase AC power supply input terminals
U/T1 - V/T2 - W/T3 AC motor output terminals (Induction or PM)
+1 - +2 / B1 - B2 Connections for DC reactor and external dynamic braking resistors
STO1 - STO2 - DCM Dual-channel Safe Torque Off inputs and signal common
RA - RB - RC Multi-function relay output (Form C)

Alternative Models & Compatibility

When upgrading older Delta VFD-E or VFD-M series drives to the modern MS300 series, verify physical cabinet mounting constraints since the MS300 is significantly narrower. Parameter files can be migrated through Delta VFDSoft, but auto-tuning should be re-executed on the MS300 platform to ensure the sensorless vector algorithms accurately map the winding resistance of older motors.

Application Pitfalls & Engineering Notes

Because this is the "N" designated model, it lacks a built-in EMC filter. If you are operating this drive in environments with sensitive instrumentation, digital load cells, or high-speed serial communications, you must install an external line filter on the input side and use fully shielded motor cables to mitigate high-frequency electromagnetic noise. Ensure the carrier frequency parameter is adjusted appropriately to maintain low thermal load inside sealed non-ventilated enclosures.

Commissioning & Wiring Tips

During initial commissioning, if the drive is not wired to an external emergency safety relay, the STO1 and STO2 terminals must be jumpered to the common reference (+24V / DCM) using the factory-provided shorting clips. Leaving these terminals open will cause the drive to display continuous safety fault states (STL1 or STL2) and block output power initialization. Ground the motor shield directly to the drive's chassis ground lug to prevent ground-loop current injection.

Installation Guidelines

CRITICAL WARNING: Prior to undertaking any physical wiring or terminal alterations, disconnect all primary supply power. Allow a minimum of 10 minutes for internal DC bus capacitors to discharge fully. Use a calibrated multimeter to confirm that voltage between the + and - terminals is under 36V DC before commencing work.
1

Mount the variable frequency drive vertically on a flat, vibration-free surface, maintaining a minimum of 50mm clearance above and below the cooling fan housing to ensure unobstructed convection airflow.

2

Verify that the source supply voltage aligns strictly with the 460V AC 3-phase input requirements. Connect input power to R/L1, S/L2, and T/L3 terminals using correctly sized copper conductors rated for at least 75 degC.

3

Connect the motor leads to terminals U/T1, V/T2, and W/T3. Do not apply main AC power to these output terminals, as this will result in immediate catastrophic failure of the drive's internal IGBT power bridge.

Loading product navigation…

What is the overload rating of the MS300 series 45A drive?

This drive features a Heavy Duty rating of 45A with an overload capability of 150% of rated current for up to 60 seconds.

Does this drive include a built-in EMC filter?

No, this model features the 'N' suffix in its part number, indicating it has no built-in EMC filter. External filtering must be installed if electromagnetic noise suppression is required.

How do I clear the STL1 or STL2 safety fault code upon startup?

The STL1 and STL2 codes indicate that the Safe Torque Off (STO) terminals are open. To enable drive operation, the STO1 and STO2 terminals must be wired to a safety relay or shorted to the +24V common terminal using factory jumpers.

Can this unit control permanent magnet synchronous motors?

Yes, the MS300 control loop natively supports both standard Induction Motors (IM) and Permanent Magnet (PM) synchronous motors in open-loop vector control mode.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...