The GE Multilin UR-9EV is a high-performance CPU module engineered for the UR Series (Universal Relay) platform, specifically utilized within advanced systems such as the T60 Transformer Protection System. This module serves as the primary processing and control hub, executing critical protection algorithms, managing communication interfaces, and driving the human-machine interface.

The UR-9EV configuration is equipped with dual RS485 communication ports supporting industrial protocols including Modbus RTU and DNP 3.0, ensuring seamless integration into SCADA systems and substation automation networks. It features an enhanced front panel assembly integrated with a localized Chinese language text display and user-programmable pushbuttons. This layout provides field operators with intuitive local control, real-time diagnostic visibility, and flexible operation right at the relay fascia. Built with robust, substation-hardened hardware, the module delivers dependable processing capabilities under harsh environmental conditions.

Features

  • Advanced Processing Core: Acts as the central processing engine for UR Series protection and control devices.
  • Dual Serial Connectivity: Integrated with dual RS485 communication ports supporting Modbus RTU and DNP protocols.
  • Enhanced Local Interface: Features an advanced faceplate layout with a wide-angle hinge assembly for simple module accessibility.
  • Localized HMI Display: Equipped with a native Chinese language character display for localized parameter and status monitoring.
  • User-Programmable Control: Includes configurable front-panel pushbuttons to execute user-defined control logic or menu navigation.
  • Substation-Hardened Design: Employs distinct blue identifying labels to prevent physical module mismatching across legacy systems.

Applications

  • Substation Automation Networks: Serves as the communication and processing backbone for SCADA and telemetry links via Modbus RTU or DNP 3.0.
  • Transformer Protection Control: Installed within the T60 Transformer Protection System to manage asset health and high-speed protection mechanisms.
  • Localized Industrial Control Panels: Deployed in industrial facilities requiring native Chinese character displays and quick tactile pushbutton control at the device fascia.

Technical Specifications

Parameter Specification
Manufacturer GE Multilin 
Module Type CPU Module 
Product Series UR Series (Universal Relay) 
Communication Interfaces RS485 and RS485 
Supported Protocols Modbus RTU, DNP 3.0 
HMI Faceplate Type Enhanced front panel 
Display Language Chinese 
Local Control Interface User-programmable pushbuttons 
Hardware Label Identification Blue label (denotes version 4.0x or higher compatibility) 
Country of Origin Canada 

Installation Guidelines

  • Control Power Removal: Module withdrawal and insertion must only be performed when all control power has been isolated and completely removed from the relay unit.
  • Electrostatic Discharge (ESD) Protection: Technicians must utilize appropriate electrostatic discharge protection (such as a properly grounded static wrist strap) when handling the module.
  • Hardware Compatibility Verification: Ensure that the CPU module label color matches the associated CT/VT and DSP module label colors. Mismatched hardware variants will cause the relay to halt and display a "DSP ERROR" or "HARDWARE MISMATCH" fault code.
  • Faceplate Operation: Unfasten the primary thumb screw to swing the wide-angle hinged front faceplate panel to the left, enabling clear access to the chassis card slots for module extraction or seating.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin UR-9EV / UR9EV UR Series CPU Module

正在加载 PDF,请稍候…

Bolehkah modul UR-9EV ditukar panas semasa rangka relay dihidupkan?

Tidak. Penarikan dan penyisipan modul mesti dilakukan hanya apabila kuasa kawalan telah diputuskan sepenuhnya dari unit untuk mengelakkan kerosakan komponen atau kecederaan peribadi.

Apa yang berlaku jika terdapat ketidakpadanan versi antara CPU ini dan modul CT/VT yang dipasang?

Modul CPU baru mempunyai label biru yang tersendiri. Jika terdapat ketidakpadanan perkakasan dengan modul lama, relay akan gagal untuk memulakan dan akan memaparkan mesej RALAT DSP atau KETIDAKPADAN PERKAKASAN.

Protokol komunikasi manakah yang disokong secara asli oleh port serial pada modul khusus ini?

Dwi port RS485 pada konfigurasi modul ini menyokong secara asli protokol Modbus RTU dan DNP 3.0 untuk integrasi industri.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Hitam
Country of origin
Kanada
Power source
Kuasa DC Dikuasakan oleh AC

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...