1 daripada 3

General Electric IS200TVBAH2ACC Mark VIe Vibration Input Terminal Board

General Electric IS200TVBAH2ACC Mark VIe Vibration Input Terminal Board

Hanya 7 item tinggal dalam stok
  • Pengilang: General Electric

  • No. Produk: IS200TVBAH2ACC

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Vibration Input Terminal Board

  • Kod Bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 1451g

  • Dimensi: 33cm x 17.8cm x 5.5cm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The IS200TVBAH2ACC operates as a high-performance vibration input terminal board developed by General Electric for deployment within the Mark VIe Speedtronic turbine control platform. This terminal board acquires real-time seismic, proximitor, velomiter, and accelerometer sensor feedback from dynamic gas, steam, and wind turbine drive assemblies. Optimized for machinery protection loops, the IS200TVBAH2ACC implements individual channel signal suppression and electromagnetic interference (EMI) filtering parameters to isolate sensitive processing elements from transient field disruptions.

Rather than relying on common instrumentation power supplies, the IS200TVBAH2ACC obtains operational stability directly from external +28 V sources, leveraging three onboard removable daughterboards to achieve critical +28 V to -28 V voltage conversion locally. The circuit card hosts standard terminal blocks paired alongside a dedicated high-density cable connector network to streamline the delivery of buffered dynamic vibration wave vectors directly into the downstream I/O processor framework.

Features

  • Flexible Transducer Interfacing: Accommodates multiple industrial measurement elements, specifically accepting proximitor, seismic, velomiter, and accelerometer transducer variations.
  • Onboard Negative Voltage Inversion: Integrates three modular, field-removable daughterboards that internally convert +28 V to -28 V to fully sustain transducer power requirements.
  • Transient Signal Filtering: Delivers dedicated surge suppression and EMI noise defense boundaries uniquely matched across each sensor channel track.
  • High-Density Monitoring Interface: Features dual integrated terminal blocks, supporting 14 dynamic sensor inputs through a total of 24 independent field terminals.
  • Buffered Diagnostic Outputs: Provisions 14 individual N24 buffered sensor outputs alongside specialized multi-pin output plugs for Bently-Nevada analytical machinery instruments.
  • Conformal Coating Insulation: Protected by a precise, thin conformal coating formulation that comprehensively seals traces against corrosive ambient plant humidity.

Applications

  • Mark VIe Speedtronic dynamic turbine vibration monitoring systems
  • Critical turbo-machinery shaft displacement and overspeed safety loops
  • Real-time predictive maintenance tracking within automated wind, steam, and gas turbine drive assemblies

Technical Specifications

Item Description / Value
Manufacturer General Electric
Series Mark VIe Speedtronic
Part Number IS200TVBAH2ACC
Functional Acronym TVBA
Functional Description Vibration Input Terminal Board
PCB Coating Conformal Coating
Functional Revision 1 A
Total Sensor Inputs 14 channels
Total Block Terminals 24 points
Buffered Signal Paths 14 N24 buffered outputs
Bently-Nevada Data Plugs 11 ports
Primary Interface Connector 37-pin connector plug
Input Voltage Framework Acquired +28 V source inputs
Weight 3.2 lb

Installation Guidelines

  • Shield Termination Grounding: Fasten the primary field cables firmly to the dedicated shield termination attachment point on the board frame to suppress induced electromagnetic or radio frequency noise.
  • Power Loop Configuration: Verify that the primary external +28 V source supplies remain functional and stable to power the voltage inversion daughterboard cards, maintaining regular TVIB board interaction profiles.
  • Electrostatic Grounding Measures: Ensure the system service engineer wears a path-to-ground ESD wrist strap during the removal or replacement of the negative voltage daughterboard modules to avoid circuit overstress.
Loading product navigation…

What happens if one of the inputs experiences an out-of-range voltage parameter?

Should any of the instrumentation input channels encounter an out-of-range voltage threshold, the linked I/O processor generates a specific diagnostic alarm to alert the system administrator.

How many buffered output channels are provided on this interface board?

The board features a total of fourteen independent N24 buffered outputs positioned alongside its primary multi-pin data connectors.

How does the module provide the negative voltage rails required for some proximity probes?

The module utilizes three onboard, removable daughterboards that convert incoming +28 V power into a localized -28 V negative voltage supply, keeping negative power paths self-contained.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Color pattern
Hijau
Country of origin
Amerika Syarikat
Power source
Kuasa DC

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...