1 daripada 1

Mitsubishi Electric FR-A840-00620-2-60 FR-A800 Series Inverter

Mitsubishi Electric FR-A840-00620-2-60 FR-A800 Series Inverter

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FR-A840-00620-2-60

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 16000g

  • Dimensi: 400 mm x 250 mm x 190 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered for high-performance motor control in demanding industrial environments, the Mitsubishi Electric FR-A840-00620-2-60 variable frequency drive delivers exceptional vector control accuracy within the FR-A800 Series architecture. This three-phase inverter is optimized for constant torque applications, providing reliable speed and torque regulation for heavy-duty machinery. With its integrated 6K-step PLC and advanced safety functionalities, the drive simplifies system architecture by eliminating the need for external controllers in localized automation loops.

Features

  • Real Sensorless Vector (RSV) Control: Achieves high-precision speed and torque control up to 400 Hz without requiring a dedicated encoder feedback loop.
  • Integrated Safety Architecture: Built-in compliance with SIL2 and PLd safety standards ensures safe torque-off (STO) functionality directly at the drive level.
  • Embedded Automation Logic: Built-in Mitsubishi L-Series PLC functionality allows for customized control programming up to 6,000 steps.
  • Energy Optimization: Optimum Excitation Control technology continuously tunes the motor flux to minimize losses, yielding up to an additional 12% energy savings over standard V/f control.
  • Diagnostic Maintenance: Internal thermal sensors and component life diagnostics track the degradation of main circuit capacitors, cooling fans, and inrush currents.

Applications

  • Winding and Tensioning Systems: Direct tension control and dancer feedback loops for paper, film, and wire lines.
  • Cranes and Hoists: Smooth brake sequence control and high-torque generation at zero speed for lifting mechanisms.
  • Machine Tool Spindles: High-speed orientation and rapid acceleration/deceleration performance under variable loads.
  • Heavy Conveyors: Master-slave torque sharing configurations for multi-drive bulk material handling systems.

Technical Specifications Table

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number FR-A840-00620-2-60
Series FR-A800
Input Voltage Rating 3-Phase 380 to 500V AC (50Hz / 60Hz)
Output Capacity (ND / Heavy Duty) 22 kW
Rated Output Current (ND) 44 A
Control Modes V/F, Advanced Magnetic Flux Vector, Real Sensorless Vector, Closed-Loop Vector
IP Protection Rating IP20 (Open Type)
Cooling Method Forced Air Cooling
Brake Chopper Built-in (requires external resistor for high duty cycles)
Shipping Weight (Calculated) 16.0 kg
Physical Dimensions (H x W x D) 400 mm x 250 mm x 190 mm

Connections and Interfaces

Terminal Designation Function / Assignment
R/L1, S/L2, T/L3 Three-phase AC power input connections
U, V, W Three-phase AC output connections to motor
P/+, PR External braking resistor connection terminals
P/+, N/- Direct DC bus connection link for common-bus sharing
S1, S2, SC Dual-channel Safety stop input terminals (STO)

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-A840-00620-2-60 is fully backwards compatible with the legacy FR-A740-00620 series parameters. By utilizing the FR-Configurator 2 software suite, users can migrate parameters without manual re-entry. Note, however, that physical footprint and terminal block locations differ slightly; ensure mounting panels accommodate the depth variance of 190 mm.

Application Pitfalls & Engineering Notes

When deploying this drive in constant-torque configurations at low frequencies (below 6 Hz), standard self-cooled motors will experience high heat generation due to reduced fan speed. In these scenarios, a motor with an independent cooling fan (forced ventilation) is required. Ensure the drive enclosure maintains a 100 mm top and bottom clearance for unrestricted heat sink airflow.

Commissioning & Wiring Tips

For reliable RS-485 or SSCNet communication, control wiring must use twisted-pair shielded cables separate from the power cables. Keep the control wiring separated from the main circuit wiring by at least 10 cm to prevent high-frequency electromagnetic interference. Connect the shield braid directly to the ground plate rather than using a pigtail connection.

Installation Guidelines

CRITICAL WARNING

Hazardous voltages remain present in the internal DC bus capacitors even after mains power is disconnected. Wait a minimum of 10 minutes after complete de-energization, and verify with a multimeter that the DC bus voltage (terminals P/+ to N/-) has discharged below 50VDC before initiating physical contact with terminal wiring.

1

Mount the inverter vertically on a flat, non-flammable vertical wall using M6 size mounting bolts. Avoid tilted installations to ensure optimal thermal chimney-effect dissipation.

2

Connect the protective earth (PE) ground wire to the designated ground terminal before routing primary three-phase lines to the R/L1, S/L2, and T/L3 terminals.

3

Ensure the terminal cover is securely locked back into place before switching on the primary input breaker to perform initial parameters verification.

Loading product navigation…

Can the FR-A840-00620-2-60 run a PM motor instead of an induction motor?

Yes. This drive supports sensorless vector control of permanent magnet (PM) motors in addition to standard induction motors, enabling high-performance operation on modern high-efficiency PM machines.

How long must I wait for the DC bus to discharge after turning off power?

You must wait at least 10 minutes and verify that the voltage between terminals P/+ and N/- is below 50VDC with a voltmeter before executing any service work.

Does this unit require an external 24VDC supply for the control card?

An external 24VDC supply is optional. It can be connected to terminals +24 and SD to power the control circuit and safety circuits while the main power supply is switched off, enabling diagnostics and communication.

What is the built-in PLC program step capacity for this model?

The integrated Mitsubishi L-Series PLC engine accommodates programs up to 6,000 steps, which can be managed directly via the FR-Configurator 2 software.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...