1 daripada 1

Mitsubishi Electric FR-A840-02160-2-60 FR-A800 Inverter

Mitsubishi Electric FR-A840-02160-2-60 FR-A800 Inverter

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FR-A840-02160-2-60

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 55000g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered for demanding industrial process control, the Mitsubishi Electric FR-A840-02160-2-60 is a highly versatile three-phase 400V class variable frequency drive from the FR-A800 series. Designed with a conformally coated circuit board (3C2) and optimized for high-power induction and permanent magnet motors, this standard-model inverter offers exceptional speed and torque regulation across various industrial environments.

Key Technical Features

  • Dual-Rating Capability: Supports multiple rating profiles including Super Light Duty (SLD), Light Duty (LD), Normal Duty (ND), and Heavy Duty (HD) for optimal motor matching.
  • Conformal PCB Coating: Features circuit board protection compliant with IEC 60721-3-3 Class 3C2, offering high resistance to corrosive gases and dust.
  • Advanced Motor Control: Supports Real Sensorless Vector (RSV) control, closed-loop vector control, and PM sensorless vector control.
  • Built-In Safety Functionality: Integrated dual-channel emergency stop (Safe Torque Off - STO) compliant with EN ISO 13849-1 Category 3/PLd.

Applications

  • Heavy-duty industrial fans, pumps, and blowers
  • Material handling, conveyors, and automated gantry systems
  • Extruders, mixers, and industrial centrifuges
  • Deep-well water pumping systems and compressors

Technical Specifications

Manufacturer Mitsubishi Electric
Model Number FR-A840-02160-2-60
Series FR-A800 Inverter Series
Voltage Class Three-Phase 380 to 500 V AC, 50/60 Hz
SLD Rated Current (Super Light Duty) 260 A
LD Rated Current (Light Duty) 216 A
ND Rated Current (Normal Duty) 180 A
HD Rated Current (Heavy Duty) 144 A
Control Logic Source/Sink logic selectable (CA Type)
Conformal PCB Coating Class 3C2 (IEC 60721-3-3 compliant)
Plated Conductor Without
Operating Ambient Temp -10 degC to 50 degC (non-freezing)
Cooling Method Forced Air Cooling
Country of Origin Japan
Shipping Weight (Calculated) 55.0 kg

Connections and Interfaces

Terminal Designation Function / Circuit Assignment
R/L1, S/L2, T/L3 Three-phase AC power supply input (380-500V)
U, V, W Three-phase variable frequency output to motor
P/+, N/- DC bus connection terminals (external brake unit option)
STF / STR Forward rotation start / Reverse rotation start control lines
S1, S2, SC Safety stop input circuit terminals (STO compliant)

Alternative Models & Compatibility

The FR-A840-02160-2-60 can directly replace legacy FR-A740-02160-EC installations. Although physical footprint differences are minimal, the A800 control parameters must be remapped using FR Configurator2 to accommodate advanced vector motor algorithms and different terminal configurations.

Application Pitfalls & Engineering Notes

When operating in Super Light Duty (SLD) mode at 260A, overload capacity is capped at 110% for 60 seconds. High-inertia or high-torque start applications (such as crushers or heavy screw conveyors) must be run under Heavy Duty (HD) parameters to prevent instant overcurrent trips (E.OC1, E.OC2, E.OC3) during ramp-up cycles.

Commissioning & Wiring Tips

Ensure the integrated EMC filter is enabled by confirming the grounding connector switch is in the correct position for your local grounding grid configuration. For long motor cables exceeding 100 meters, a dV/dt or sine-wave filter must be installed to prevent voltage reflection damage to the motor windings.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE RISK

Isolate all input power supplies before handling control or main circuit terminations. Wait at least 10 minutes post-power-off to allow internal DC link capacitors to discharge below 50V DC. Verify voltage across P/+ and N/- terminals using a certified high-voltage multimeter before proceeding with wiring.

1

Mount the inverter vertically inside a clean, IP54 or NEMA 12 enclosure if operating in environments prone to conductive dust or high ambient humidity.

2

Connect the primary ground terminal to the system ground busbar using the specified gauge to minimize ground loop currents and high-frequency noise EMI.

3

Route control and communication wiring completely segregated from the heavy 3-phase AC input and motor output cabling to eliminate crosstalk.

Loading product navigation…

What is the overload capacity of this model under Heavy Duty (HD) rating?

Under the Heavy Duty (HD) profile with a rated current of 144A, the inverter provides an overload capacity of 150% for 60 seconds and 200% for 3 seconds, ideal for high-starting-torque applications.

Does this variable frequency drive include conformal coating for harsh environments?

Yes. This drive features printed circuit boards conformally coated to meet Class 3C2 specifications according to IEC 60721-3-3, providing robust protection against humidity, dust, and corrosive industrial gases.

Can I bypass or disable the internal EMC filter on this CA type model?

Yes, the integrated EMC filter can be easily enabled or disabled using the physical grounding connector switch, allowing compatibility with floating or high-impedance grounded distribution networks (IT grids).

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...