1 daripada 1

Mitsubishi Electric FR-A840-37-1 FR-A800 Series Variable Frequency Drive

Mitsubishi Electric FR-A840-37-1 FR-A800 Series Variable Frequency Drive

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FR-A840-37-1

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 43000g

  • Dimensi: 490 mm x 300 mm x 250 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered to meet the demands of heavy-duty industrial motor applications, the Mitsubishi Electric FR-A840-37-1 is a high-performance, three-phase Variable Frequency Drive (VFD) belonging to the premier FR-A800 Series. Designed for robust speed and torque control, this inverter features an integrated FM terminal configuration for high-precision analog pulse train monitoring. Offering seamless integration into existing control architectures, the unit features built-in Modbus RTU protocols and multi-point RS-485 serial interfaces, making it an excellent fit for demanding automation setups requiring exact velocity tracking and high starting torque.

Key Features

  • Real Sensorless Vector Control (RSVC): Delivers exceptional torque performance at near-zero speeds without requiring an external encoder.
  • Flexible Output Frequencies: Supports a wide operating range from 0.2 Hz up to 590 Hz to handle diverse high-speed industrial machinery.
  • FM Control Terminals: Outfitted with dedicated FM pulse-train and analog voltage monitoring channels (0-10Vdc) for precise feedback loop integration.
  • Built-In RS-485 Interface: Built-in support for RS-422 and RS-485 multi-drop communication running native Modbus RTU protocols.
  • IP00 Open-Type Chassis: Built for optimal space-saving layouts within localized, climate-controlled industrial control panels.

Industrial Applications

  • High-Inertia Centrifuges: Manages regenerative energy and deceleration profiles safely.
  • Heavy-Duty Conveyor Systems: Provides high breakaway torque for starting fully loaded belts.
  • Extruders and Mixers: Maintains constant torque control across varying material viscosity ranges.
  • Industrial Fan & Pump Arrays: Reduces energy consumption through precise affinity-law speed regulation.

Technical Specifications

Parameter Value / Specification
Manufacturer Mitsubishi Electric
Model Number FR-A840-37-1
Series FR-A800 Series
Applicable Motor Capacity 37 kW (50 HP)
Supply Voltage (AC) 3-Phase 380Vac to 500Vac (50/60 Hz)
Output Phase 3-Phase AC
Output Frequency Range 0.2 Hz to 590 Hz
Communication Protocols Modbus RTU, RS-232, RS-422, RS-485
Analog Output Channels 1 x Analog Output (0-10Vdc) via FM Terminal
Degree of Protection IP00 (Open Type)
Country of Origin Japan
Shipping Weight (Calculated) 43.0 kg (94.8 lbs)
Package Dimensions (Calculated) 490 mm x 300 mm x 250 mm

Connections and Interfaces

Terminal Block Designation Functional Circuit Assignment
R/L1, S/L2, T/L3 3-Phase Main AC Power Supply Input
U, V, W 3-Phase Variable Frequency Output to Motor
FM Pulse train monitor / Analog signal output (0-10Vdc)
TXD+ / TXD- / RXD+ / RXD- RS-485 / Modbus RTU Communication interfaces
SD Common Terminal for External Analog Command Reference

Alternative Models & Compatibility

The FR-A840-37-1 serves as a direct functional replacement for the older generation FR-A740-37K drive variants. If migrating from the A700 series, verify panel space clearances, as physical depths and wiring terminal profiles differ slightly. Configuration and parameter profiles can be fully imported and converted using Mitsubishi Electric's FR Configurator2 software platform to minimize deployment downtime.

Application Pitfalls & Engineering Notes

With a high power rating of 37 kW (50 HP), this drive generates significant heat during continuous full-load operations. It requires installation inside a dedicated, well-ventilated enclosure with a minimum of 100mm clearance on both the top and bottom of the unit. When using the drive in high-duty cycle applications, ensure external braking resistors are sized correctly to prevent overvoltage tripping (E.OV3) during regenerative braking events.

Commissioning & Wiring Tips

To mitigate electromagnetic interference (EMI) issues, run the 3-phase output motor connections (U, V, W) in continuous shielded cable, grounding the shield at both the drive enclosure and the motor terminal box. When implementing serial communications, ensure parameter 117 (Station Number) and parameter 118 (Baud Rate) are mapped correctly prior to initiating cyclic polling over the Modbus network.

Installation Guidelines

CRITICAL WARNING: Hazardous voltages remain present inside the drive capacitor bank for up to 10 minutes after main power is disconnected. Always verify that the charge lamp is fully extinguished and use a calibrated digital multimeter to verify zero DC bus voltage before initiating termination work.
1

Mount the IP00 chassis vertically onto a flat, non-flammable back panel using M6 or M8 mounting screws to allow unobstructed convection currents.

2

Connect the physical system ground to the PE terminals before terminating the main input power lines (R/L1, S/L2, T/L3).

3

Run control signals and analog feedback loops (FM terminal block) through separate metal conduits isolated from heavy AC power wiring.

Loading product navigation…

What is the difference between the FM terminal and AM terminal variants on this drive?

The FM terminal on the FR-A840-37-1 functions as a pulse train monitor output (commonly up to 50kpps) but can also be configured to supply a 0-10Vdc analog voltage monitoring signal, whereas AM variants typically output standard analog voltage or current loops.

How do I resolve an E.OV3 fault code during motor deceleration?

An E.OV3 indicates overvoltage during deceleration. To resolve this, extend the deceleration time (Parameter 8), disable deceleration overvoltage avoidance, or install an external brake unit and power resistor.

Can the FR-A840-37-1 be programmed directly without a computer software interface?

Yes, basic parameter editing, motor tuning, and speed commands can be performed directly on-site using the built-in keypad/display unit on the drive's front cover.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat