1 daripada 1

Mitsubishi Electric FR-E720-5.5K FR-E700 Series Inverter

Mitsubishi Electric FR-E720-5.5K FR-E700 Series Inverter

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FR-E720-5.5K

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered to deliver high-performance motor speed control in heavy industrial configurations, the Mitsubishi Electric FR-E720-5.5K is a three-phase 200V class variable frequency drive from the esteemed FR-E700 Series. Built to handle standard and heavy-duty torque demands, this 5.5 kW (7.5 HP) inverter integrates advanced magnetic flux vector control to supply reliable low-speed torque and dynamic responsiveness. It serves as a dependable control element for machinery requiring rapid acceleration, deceleration, and high-precision velocity regulation.

Features

  • High-Performance Vector Control: Advanced magnetic flux vector control algorithm delivers 150% torque at speeds as low as 1 Hz.
  • Compact Enclosure Footprint: Space-saving chassis design allows side-by-side installation to minimize control panel volume.
  • Removable Terminal Block: Simplifies wiring maintenance and reduces system downtime during hardware swap-outs.
  • Safety-Stop Functionality: Integrated dual-channel emergency stop input complies with international safety standards (EN ISO 13849-1 Category 3 / PLd).
  • USB Configuration Interface: Dedicated diagnostic port permits rapid parameter upload, download, and real-time monitoring via FR Configurator software.

Applications

  • Material Handling: High-torque conveyor systems, sorting machines, and lifters.
  • Process Machining: Variable speed control for mixers, agitators, and industrial centrifuges.
  • Fluid Management: Constant torque control of positive displacement pumps and centrifugal pumping stations.
  • HVAC Systems: Air handling unit fans, industrial blowers, and exhaust ventilation assemblies.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model / Article Number FR-E720-5.5K
Product Series FR-E700 Series
Voltage Class Three-phase 200V class (200 to 240V AC, 50/60Hz)
Inverter Capacity 5.5 kW (7.5 HP)
Recommended MCCB (No Reactor) 50 A
Recommended MCCB (With Reactor) 40 A
Magnetic Contactor (MC) S-N25
Control Logic Options Sink (NPN) or Source (PNP) selectable
Cooling Method Forced air cooling (with cooling fan)
Net Weight 4.3 kg
Shipping Weight (Calculated) 7.0 kg

Connections and Interfaces

Terminal Symbol Function Description
R/L1, S/L2, T/L3 Main power input terminals (Three-phase 200-240V AC)
U, V, W Inverter output terminals connected directly to the AC induction motor
STF / STR Forward Run / Reverse Run terminal contact command
SD Common terminal for control input contacts (Sink common)
PC Common terminal for transistor outputs and external power source (Source common)
10, 2, 5 Analog voltage input interface (0 to 10V DC speed reference)
4, 5 Analog current input interface (4 to 20mA speed reference)
A, B, C Form C relay output contact (Fault/Alarm indicator)

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-E720-5.5K serves as a direct upgrade to legacy FR-E520-5.5K models. Keep in mind that control terminal dimensions and layout differ; the FR-E700 series utilizes a removable control connector card which is not physically compatible with FR-E500 backplanes. Parameter maps are highly consistent, though parameter settings for vector control (Pr. 80 and Pr. 81) must be manually reconfigured to match the motor's slip frequency and excitation current.

Application Pitfalls & Engineering Notes

During constant torque operation at frequencies below 10 Hz, standard non-ventilated AC motors can overheat rapidly. Under these conditions, specify a force-cooled motor or derate the load. Ensure the continuous ambient temperature in enclosed panels does not exceed 50 degC. If installing multiple drives side-by-side inside a single cabinet, the top shielding plates must be removed to guarantee proper airflow convection.

Commissioning & Wiring Tips

To transition the digital inputs from standard Sink logic (NPN) to Source logic (PNP), isolate the main power and toggle the physical logic selector switch located directly beneath the control circuit terminal block. When commissioning through terminal 4 (4-20mA current input), set parameter AU (Pr. 184) to activate Terminal 4 input. Run twisted, shielded-pair (STP) wiring for all analog reference cables and ground the shield only at the drive end (Terminal 5) to isolate signal lines from high-frequency common-mode noise.

Installation Guidelines

CRITICAL SAFETY WARNING

Before installing or servicing this drive, fully isolate the mains input power. Wait at least 10 minutes for the internal DC bus capacitors to discharge. Verify the DC bus voltage across terminals P/+ and N/- is below 30V DC using a certified digital multimeter. Failure to follow discharge protocols can result in severe electrical shock, personal injury, or equipment destruction.

1
Mechanical Mounting: Mount the drive vertically to a flat, non-flammable back panel using M5 screws. Maintain at least 50mm clearance on both sides and 100mm clearance above and below the unit for heat dissipation.
2
Main Power Wiring: Connect three-phase 200V supply conductors to terminals R/L1, S/L2, and T/L3 via the recommended 50A MCCB. Connect the motor leads to U, V, and W. Ensure the protective earth (PE) terminal is securely grounded using a low-impedance copper conductor.
3
Control Circuit Integration: Wire standard start/stop signals to the STF/STR inputs. If external analog controls are required, connect the input references to terminal 2 or 4. Check the position of the Sink/Source jumper switch to match external PLC I/O configurations.
4
Initial Power-Up and Calibration: Energize the unit and set motor nameplate data, including rated voltage, current, and frequency. Execute an off-line auto-tuning sequence (Pr. 96) to optimize the internal motor flux model for efficient and stable dynamic performance.
Loading product navigation…

What is the recommended breaker size for the FR-E720-5.5K?

A 50 A molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELB) is recommended without a reactor connection. If an AC or DC reactor is connected to improve power factor, a 40 A breaker should be used.

Does this model support Modbus RTU communications?

Yes, the drive features built-in Modbus RTU communication capabilities through the integrated RS-485 RJ45 interface on the front panel, supporting terminal network control without requiring additional interface cards.

What is the physical weight of this VFD?

The net weight of the device is 4.3 kg (9.48 lbs). Packaged and configured for dispatch, the estimated shipping weight is approximately 7.0 kg (15.4 lbs).

Can I configure the digital control terminals to PNP logic?

Yes. The control circuit logic can be toggled between Sink (NPN, negative common) and Source (PNP, positive common) using a sliding select switch located beneath the control circuit terminal block.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...