1 daripada 1

Mitsubishi Electric FR-F840-03250-2-60 FR-F800 Series Inverter

Mitsubishi Electric FR-F840-03250-2-60 FR-F800 Series Inverter

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FR-F840-03250-2-60

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives (VFD)

  • Pembayaran: T/T, Western Union

  • Berat: 74000g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Optimizing flow control in heavy-duty pump and fan installations, the Mitsubishi Electric FR-F840-03250-2-60 functions as a heavy-capacity variable frequency drive from the FR-F800 series. This industrial inverter is engineered specifically for fan, pump, and compressor control, delivering high-efficiency operation through intelligent energy-saving algorithms. Incorporating advanced excitation control, it continuously monitors load demand to optimize torque and reduce power consumption in real time.

Features

  • Advanced Optimum Excitation Control: Automatically balances motor magnetic flux to achieve high energy efficiency even under changing load conditions.
  • Dual Overload Rating: Supports Super Light Duty (SLD) and Light Duty (LD) operational configurations to match specific load profiles.
  • Multi-Pump Control: Built-in advanced PID and multi-pump control algorithms allow coordinated operation of multiple auxiliary pumps.
  • Integrated Safety Function: Features functional safety inputs compliant with SIL 2 / PL d safety standards.
  • Onboard PLC Functionality: Enables basic logic programming directly within the inverter, reducing the need for external mini-PLCs.

Applications

  • Water and Wastewater: Intake pumps, booster stations, and aeration blower systems.
  • HVAC Systems: Large-scale industrial air handling units (AHUs), cooling towers, and chillers.
  • Factory Automation: Dust collectors, exhaust fans, and municipal ventilation systems.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number FR-F840-03250-2-60
Series Name FR-F800 Series
Input Voltage Range 3-Phase 380 to 500 VAC (50/60 Hz)
Rated Output Current (SLD) 325 A
Rated Output Current (LD) 290 A
Control Method V/f Control, Advanced Magnetic Flux Vector Control, Optimum Excitation Control
Enclosure Protection Rating IP00 (Open Type)
Operating Ambient Temperature -10 to +50 degC (non-freezing, LD rating up to +40 degC without derating)
Shipping Weight (Calculated) 74.0 kg

Connections and Interfaces

Terminal Group Function Assignment
R/L1, S/L2, T/L3 3-Phase AC main power input connections.
U, V, W 3-Phase AC motor power output connections.
P/+, PR, N/- DC link terminals for optional braking units or shared DC bus configurations.
Control Terminals Analog inputs (voltage/current), multi-function digital inputs, safety stop (S1/S2/SIC), and relay outputs.

Alternative Models & Compatibility

The unit acts as a direct modern replacement for the legacy FR-F740-03250 series. When replacing older F700 series models, parameter configuration files can be migrated using the FR Configurator2 software suite. Note that physical dimensions and mounting bolt patterns may differ slightly from the legacy series; ensure layout spacing in enclosed cabinets allows for the ventilation clearances required by the FR-F800 design.

Application Pitfalls & Engineering Notes

This large-capacity inverter exhibits significant thermal dissipation requirements during peak loads. Ensure your electrical enclosure has active ventilation capable of moving hot air away from the drive heat sinks, especially if operating continuously in ambient environments above 40 degC. For installations exceeding 1000 meters above sea level, apply a current derating factor of 1% per 100 meters up to a maximum altitude of 2500 meters.

Commissioning & Wiring Tips

Always ground the drive independently using a Class D grounding connection with a low impedance path. Ground currents generated by high-frequency PWM switching can interfere with sensitive near-field analog signals. It is highly recommended to run encoder, transducer, and control loops in separate, shielded conduits isolated from the main U/V/W motor output cables by at least 30 cm.

Installation Guidelines

CRITICAL WARNING: HIGH-VOLTAGE RISK

Before beginning any installation, maintenance, or terminal wiring work, completely disconnect the main power source. Wait at least 10 minutes for the internal DC bus capacitors to discharge safely. Verify that the charge indicator lamp on the front cover is completely off and measure the voltage across terminals P/+ and N/- to confirm it is below 30 VDC.

1
Mount the inverter vertically onto a flat, non-flammable vertical surface (such as a metal backplate) to guarantee optimal convective airflow across the rear-mounted heat sinks.
2
Connect structural grounds to the designated ground terminals. Securely connect the R/L1, S/L2, and T/L3 incoming power lines and the U, V, and W motor cables using the specified M8/M10 terminal bolt torque specs.
3
Wire the external safety inputs to the dual-channel S1/S2 safety terminals if emergency stop integration is required, ensuring the jumper is removed if using an external safety relay.
Loading product navigation…

What is the difference between Super Light Duty (SLD) and Light Duty (LD) ratings for this inverter?

The SLD rating supports continuous currents up to 325 A with 110 percent overload capacity for 60 seconds, ideal for low-torque fan and centrifugal pump loads. The LD rating supports up to 290 A with 120 percent overload capacity for 60 seconds, providing higher torque handling for general-purpose applications.

Can this drive run without an external 24 VDC control power supply?

Yes, the inverter can operate utilizing the internal power generated from the main AC input line. However, an external 24 VDC supply can be connected to the control terminal block to keep control circuits and communications active when main power is disconnected.

How do I address electromagnetic interference (EMI) issues affecting nearby analog sensors?

Ensure the motor cable is shielded with 360-degree grounding at both ends, separate signal wiring from power cables by a minimum of 30 cm, and utilize the built-in EMC filter by confirming the physical grounding jumper is correctly installed.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...