Mitsubishi Electric FX5-ENET/IP MELSEC iQ-F Series Network Module

Mitsubishi Electric FX5-ENET/IP MELSEC iQ-F Series Network Module

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FX5-ENET/IP

  • Negara asal:Amerika Syarikat

  • Jenis Produk: PLC Network Modules

  • Pembayaran: T/T, Western Union

  • Berat: 1500g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered to expand the connectivity of the MELSEC iQ-F controller platform, the Mitsubishi Electric FX5-ENET/IP network module provides dedicated EtherNet/IP and standard Ethernet communication capabilities. Integrating this module into your automation architecture enables the FX5 CPU to act as both an EtherNet/IP scanner (master) and adapter (slave) simultaneously, facilitating seamless data exchange with remote I/O, variable frequency drives, and third-party instruments. Operating on a 24 V DC internal power supply with a low current draw of 110 mA, it delivers high-performance industrial networking without putting unnecessary strain on the system's power budget.

Features

  • Dual-role capability functioning as both an EtherNet/IP CIP communication scanner and adapter.
  • Supports standard Ethernet communication protocols alongside industrial EtherNet/IP on a single physical link.
  • Seamless integration with GX Works3 configuration software for drag-and-drop network mapping.
  • Compact form factor designed for direct right-side extension bus connection to FX5U or FX5UC CPU modules.
  • Diagnostic LED array for real-time link status, module health, and network collision monitoring.

Applications

  • Multi-Vendor Integration: Connecting MELSEC iQ-F controllers to third-party EtherNet/IP compliant devices such as sensors and vision systems.
  • Distributed Field I/O: Managing remote I/O drops across large manufacturing footprints with minimal latency.
  • Drive Control: Real-time speed and torque command routing to compatible variable speed drives over industrial Ethernet.
  • SCADA and HMI Bridging: Serving high-throughput data to supervisor level control rooms and operator interfaces.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Number FX5-ENET/IP
Series MELSEC iQ-F Series
Module Type EtherNet/IP Network Module
Internal Power Supply 24 V DC
Current Consumption 110 mA
Transmission Rate 100 Mbps / 10 Mbps (Auto-negotiation)
Communication Interface RJ45 Port (1 port)
Max. Cable Segment Length 100 meters
Shipping Weight (Calculated) 1.5 kg

Status LED Configurations

LED Indicator Operational State Meaning
RUN ON: Normal operation; OFF: Power off or hardware watchdog error.
ERR Flashing/ON: Hardware error or incorrect module parameter configuration.
NS (Network Status) Green (ON): Online connected; Red (Flashing): IP address conflict or connection timeout.
MS (Module Status) Green (ON): Module is operating normally; Red (ON): Unrecoverable hardware failure.

Empirical Engineering Insights

Alternative Models & Compatibility

Unlike the built-in Ethernet port on FX5U CPU modules, which primarily processes CC-Link IE Field Basic, Modbus/TCP, and MELSOFT connection protocols, the FX5-ENET/IP is explicitly optimized for heavy-duty CIP (Common Industrial Protocol) traffic. If your network topology mandates cyclic, high-speed Class 1 implicit messaging with third-party components, this module must be appended. Note that firmware version 1.040 or higher in the host FX5 CPU is required for full feature exploitation.

Application Pitfalls & Engineering Notes

During high-traffic cyclic communication periods, network jitter can trigger NS fault codes. It is highly recommended to isolate EtherNet/IP messaging traffic from plant-wide IT office networks using managed switches with IGMP snooping configured. When mounting multiple extension modules, position the FX5-ENET/IP as close to the CPU as possible to ensure structural bus signaling integrity.

Commissioning & Wiring Tips

Always use Category 5e (or better) Double-Shielded Twisted Pair (S/FTP) cabling in high electromagnetic noise environments. Avoid routing the network cable parallel to high-voltage lines or variable frequency drive output cables to prevent induced noise from corrupting data packets.

Installation Guidelines

CRITICAL WARNING:

Ensure all AC and DC external power sources feeding the host PLC and associated field circuitry are completely de-energized before mounting, removing, or wiring the FX5-ENET/IP network module. Failure to do so can result in electrical shock, hardware failure, or unstable CPU bus behavior.

1
Align the module expansion connector with the right-side extension port of the host FX5 CPU or preceding expansion module.
2
Carefully press the module onto the DIN rail until the mounting hook clicks firmly into position. Secure the module extension joint latch.
3
Connect the system ground terminal to an isolated, low-impedance functional earth ground point. Do not share this ground path with high-current equipment.
4
Insert the shielded Ethernet RJ45 network plug into the communication port until it snaps securely. Power up the system and proceed with the hardware parameter mapping via GX Works3.
Loading product navigation…

Can the FX5-ENET/IP run on an external 24 V DC power supply?

No. The FX5-ENET/IP draws its operational power of 110 mA directly from the 24 V DC internal system power supply rail provided by the host FX5 CPU module via the side extension connector.

Does this module support both Class 1 and Class 3 EtherNet/IP communications?

Yes. The module supports Class 1 cyclic (implicit) messaging for real-time control and Class 3 message-based (explicit) communications for parameter exchanges, alongside standard UCMM protocols.

What is the physical connection port on the FX5-ENET/IP?

It features a single RJ45 connector that supports auto-negotiation between 10BASE-T and 100BASE-TX configurations, allowing a maximum standard segment length of 100 meters.

What software is required to configure the network module settings?

All configuration, network mapping, IP address assignments, and routing for the module are handled natively in GX Works3 using the built-in EtherNet/IP Configuration tool.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...