1 daripada 1

Omron CVM1-PA208 CVM1 Series Power Supply Unit

Omron CVM1-PA208 CVM1 Series Power Supply Unit

Hanya 2 item tinggal dalam stok
  • Pengilang: Omron

  • No. Produk: CVM1-PA208

  • Negara asal:Jepun

  • Jenis Produk: PLC Power Supply Modules

  • Pembayaran: T/T, Western Union

  • Berat: 9500g

  • Dimensi: 24.5 x 14.0 x 9.5 cm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered specifically for legacy CV-series backplane architectures, the Omron CVM1-PA208 supplies reliable, low-noise DC control power directly to the rack's system buses. This high-capacity power module accepts a wide AC input range and converts it to a highly stable 5 VDC, 8 A output, which is crucial for maintaining processor integrity and preventing backplane communication errors. The unit is optimized for heavy-duty industrial configurations where PLC modules require consistent current supply without voltage sags.

Features

  • High-current 8 A output capacity at 5 VDC to power dense I/O racks and high-performance CPUs.
  • Flexible AC input selection accommodating standard industrial line voltages.
  • Integrated RUN output relay contact for external monitoring of power supply health.
  • Robust noise filter circuitry to shield sensitive internal logic from electrical line transients.
  • Overcurrent and overvoltage protection limits to prevent downstream component damage during field faults.

Applications

  • Omron CV500, CV1000, and CV2000 PLC Rack Installations.
  • Automotive assembly line host control units.
  • Large-scale material handling and distribution systems.
  • Water treatment and chemical plant automation backplanes.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number CVM1-PA208
Input Voltage 100 to 120 VAC / 200 to 240 VAC (selectable)
Frequency Rating 50 / 60 Hz
Output Voltage 5 VDC
Output Current 8 A
Power Consumption 150 VA
Operating Temperature 0 to 55 degC (32 to 131 degF)
Country of Origin Japan
Shipping Weight (Calculated) 1.50 kg
Package Dimensions (Calculated) 24.5 x 14.0 x 9.5 cm

Connections and Interfaces

Terminal Label Function / Circuit Assignment
AC100-120V / AC200-240V Main AC line power supply input terminals.
LG Line ground (noise filter ground) to reduce common-mode high-frequency interference.
GR Frame Ground terminal connected directly to the system grounding bar.
RUN OUT Relay contact terminals (SPST-NO) that close when the CPU is operating normally.

Alternative Models & Compatibility

The CVM1-PA208 power supply replaces standard or lower amperage modules within the CV family (such as 3 A and 5 A variants) to support system expansions containing high-density digital or analog cards. When updating backplane hardware, verify that total current consumption on the 5 VDC internal bus does not exceed the unit's 8 A output ceiling.

Application Pitfalls & Engineering Notes

Overheating in sealed, non-ventilated enclosures can lead to accelerated aging of the internal smoothing capacitors. Keep a minimum vertical spacing of 20 mm around the rack power unit to allow convective cooling. If output voltage drops below 4.75 VDC, the system watchdog will trip, halting PLC execution as a safety precaution.

Commissioning & Wiring Tips

Ensure that the Line Ground (LG) and Frame Ground (GR) terminals are wired correctly. Loop the GR terminal with a heavy, low-impedance ground strap directly to your panel plate. Leaving the GR terminal disconnected or sharing a daisy-chained ground with high-noise variable frequency drives (VFDs) can introduce electromagnetic interference, causing intermittent CPU memory corruptions.

Installation Guidelines

CRITICAL WARNING

Disconnect all incoming AC electrical power sources before handling, mounting, or wiring the terminal block. Touch hazards exist at input terminals when line power is applied. Verify the absence of voltage with a properly calibrated multimeter prior to starting system integration.

1 Align the bottom-hook mechanism of the power supply module with the designated base slot on the CV-series backplane.
2 Pivot the module smoothly upward into the backplane, pressing firmly until the top connector seat snaps completely home.
3 Secure the upper module retaining screw to the chassis to ensure mechanical grounding and guard against vibration-induced displacement.
4 Complete the electrical terminal wiring, torque terminal screws to 1.2 N-m, and apply protective terminal covers before energization.
Loading product navigation…

Does this power supply unit support auto-ranging voltage input?

No. The input voltage range is manually configured or jumper-selected at the terminal block. Ensure that your terminal connections match the 100-120 VAC or 200-240 VAC supply lines before power up.

What is the function of the RUN OUT contact?

The RUN output is a dry relay contact that closes when the internal system logic voltage is normal and the CPU executes normally. It is commonly integrated into master control or safety circuit loops.

Can I upgrade my existing CV500 power supply to this 8 Amp module?

Yes. This high-capacity module is pin-compatible with CV500, CV1000, and CV2000 backplanes, offering a robust power upgrade for configurations containing power-hungry I/O or communication cards.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jepun

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...