Omron G3PE-235B-3N G3PE Series 3-Phase Solid State Relay

Omron G3PE-235B-3N G3PE Series 3-Phase Solid State Relay

Hanya 3 item tinggal dalam stok
  • Pengilang: Omron

  • No. Produk: G3PE-235B-3N

  • Negara asal:Jepun

  • Jenis Produk: 3-Phase Solid State Relays

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for high-frequency switching of industrial heating elements, the Omron G3PE-235B-3N provides robust 3-phase solid-state control with integrated zero-cross functionality. This solid-state contactor operates with a control input of 12 to 24 VDC and is engineered to switch rated loads up to 240 VAC at an output current of 35 A (at 40 degC ambient temperature). Utilizing phototriac isolation, the device isolates the low-voltage control circuitry from high-voltage transients on the load side, delivering highly reliable thermal management in demanding environments.

Features

  • Integrated heat sink optimizes thermal dissipation, maintaining performance at elevated ambient temperatures.
  • Built-in zero-cross circuit minimizes electromagnetic interference (EMI) and electrical noise during switching transitions.
  • Phototriac isolation provides 100% galvanic separation between input and output channels.
  • Screw terminal construction ensures secure, vibration-resistant terminations for high-current wiring.
  • DIN-rail and panel mounting configurations allow for flexible cabinet integration.

Applications

  • Industrial reflow ovens and packaging machinery heat-sealing bars.
  • Semiconductor manufacturing chamber and deposition heater controls.
  • Plastics extrusion, injection molding, and thermoforming equipment.
  • Environmental testing chambers and industrial climate control systems.

Technical Specifications

Manufacturer Omron
Model / SKU G3PE-235B-3N
Control Input Voltage 12 to 24 VDC
Operating Input Range 9.6 to 30 VDC
Input Current 10 mA max. (at 24 VDC)
Must Operate / Release Voltage 9.6 VDC max. / 1 VDC min.
Rated Load Voltage 100 to 240 VAC
Load Voltage Range 75 to 264 VAC
Load Current 35 A (at 40 degC ambient)
Minimum Load Current 0.5 A
Inrush Current Resistivity 440 A (60 Hz, 1 cycle)
Permissible I²t Value 1260 A²s
Applicable Load Capacity 12.1 kW (at 200 VAC)
Isolation Method Phototriac
Zero Cross Function Equipped
Terminal Structure Screw Terminal
Weight 3.0 kg

Connections and Interfaces

Terminal Group Designation Function / Connection Assignment
Input / Control Terminals A1 (+) Positive DC Control Input (12 to 24 VDC)
A2 (-) Negative DC Control Input (Common / Ground)
Output / Power Line Terminals L1 / L2 / L3 AC Line Inputs for Phase A, B, and C (100 to 240 VAC)
T1 / T2 / T3 AC Load Terminals outputting to heater/load circuits
Ground / PE Protective Earth ground terminal connected to the heat sink block

Empirical Engineering Insights

Alternative Models & Compatibility

The "3N" suffix specifies a model with a built-in heat sink and a 3-phase configuration without a built-in varistor. It directly replaces legacy G3PE configurations that match the 35 A current profile, but panel space requirements must be verified due to the integrated cooling profile. When migrating from 2-phase control systems (such as the G3PE-235B-2N) to 3-phase, ensure that your control PLC program and safety interlocks account for the switching of all three phases to optimize line balance and eliminate floating neutral potentials on delta-connected loads.

Application Pitfalls & Engineering Notes

Thermal derating is the primary failure vector in enclosed industrial cabinets. The 35 A rating is calculated at an ambient temperature of 40 degC or lower. If the internal panel ambient temperature rises to 60 degC, the maximum continuous load current must be derated by approximately 40%. Ensure a minimum vertical clearance of 80 mm and a horizontal clearance of 30 mm between the G3PE-235B-3N and surrounding hardware to maintain convection airflow through the heat sink fins.

Commissioning & Wiring Tips

To prevent localized high resistance and terminal charring, power terminals must be torqued precisely to 1.47 to 1.96 N-m using M5 terminal screws. Do not use tinned wire ends in screw clamp terminals; crimped pin terminals or ring lugs are highly recommended. If switching inductive heating elements rather than purely resistive loads, verify that the load inrush peak remains well within the 440 A (at 60 Hz) non-repetitive rating to prevent internal phototriac degradation.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE RISK

De-energize all 3-phase main power supply feeds and auxiliary control circuits before handling terminals or attempting mounting. Wait at least 5 minutes post de-energization to allow residual charges to bleed down. Verify zero voltage state using a calibrated multi-meter across all lines before executing wiring.

1
Mechanical Mount: Mount the device vertically on a standard 35mm DIN rail or directly to a backplane using the mounting screws. Ensure the cooling fins run vertically to facilitate natural convection.
2
Grounding: Connect the Protective Earth (PE) ground terminal of the heat sink assembly to the main panel grounding bus using a low-impedance copper conductor.
3
Input Wiring: Wire the 12 to 24 VDC control lines to the positive A1 and negative A2 terminals. Ensure polarity is maintained; incorrect polarity will prevent activation.
4
Load Wiring: Connect the 3-phase incoming lines to L1, L2, and L3, and the output heater lines to T1, T2, and T3. Verify that the load balance across all three legs does not exceed 35 A per phase.
Loading product navigation…

What is the purpose of the zero-cross function in the G3PE-235B-3N?

The zero-cross function ensures that the relay switches ON only when the AC load voltage is close to zero. This significantly reduces inrush currents, limits electrical transient noise, and minimizes electromagnetic interference (EMI) on nearby communication networks.

How does ambient temperature affect the current-carrying capacity of this solid-state relay?

The maximum rated current of 35 A is specified at an ambient temperature of 40 degC or below. Above 40 degC, the allowable load current decreases in accordance with the thermal derating curve of the device to prevent internal component damage.

Can the G3PE-235B-3N be used to switch inductive motor loads?

The G3PE-235B-3N is optimized for switching resistive heating loads (AC-51 duty). While it can switch inductive loads, inrush currents must be carefully calculated to ensure they do not exceed the non-repetitive surge rating of 440 A.

What is the recommended torque specification for the power terminal screws?

The power terminals use M5 screw sizes and must be tightened to a precise torque specification of 1.47 to 1.96 N-m to guarantee stable electrical contact and prevent thermal hot spots.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Jepun

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...