1 daripada 1

Omron K3HB-HTA 100-240VAC K3HB-H Series Temperature Indicator Base Unit

Omron K3HB-HTA 100-240VAC K3HB-H Series Temperature Indicator Base Unit

Hanya 5 item tinggal dalam stok
  • Pengilang: Omron

  • No. Produk: K3HB-HTA 100-240VAC

  • Negara asal:Jepun

  • Jenis Produk: Temperature Indicators

  • Pembayaran: T/T, Western Union

  • Berat: 300g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Thermal process monitoring in automation networks is optimized through the Omron K3HB-HTA 100-240VAC, a high-visibility temperature indicator base unit designed for extensive industrial integration. Engineered to serve as a high-precision instrumentation hub, this device processes inputs from both thermocouples and platinum-resistance thermometers, converting critical thermal data into immediate visual readouts and downstream control signals. Its robust modular housing allows for the insertion of auxiliary output and communication cards, adapting seamlessly to centralized control architectures or standalone monitoring panels.

Key Features

  • Universal Temperature Input (TA Code): Directly compatible with Platinum-resistance thermometers (Pt100) and an extensive range of thermocouples (K, J, T, E, L, U, N, R, S, B, W).
  • High-Contrast Dual Display: Features a dual-color negative LCD screen with a 14.2 mm green/red configurable PV display and a 4.9 mm green SV display.
  • Flexible Modular Architecture: Accepts optional boards for DeviceNet, RS-485, RS-232C, linear current outputs, or relay outputs to match specific system requirements.
  • Wide Supply Range: Operational on any standard industrial line voltage from 100 to 240 VAC.

Industrial Applications

  • Plastic Extrusion & Injection Molding: Continuous monitoring of barrel and die zones to prevent polymer degradation.
  • Heat Treatment Furnaces: Precise tracking of thermal processing cycles and over-temperature safety limits.
  • Environmental Chambers: Stable indication of internal atmospheric test conditions.
  • Packaging Machining: Monitoring heat-sealing bar temperatures for consistent packaging integrity.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model / Article Number K3HB-HTA 100-240VAC
Series K3HB-H Series
Input Sensor Code TA (Thermocouple & Platinum-resistance thermometer)
Supported Thermocouples K, J, T, E, L, U, N, R, S, B, W
Supported RTDs Pt100
Supply Voltage 100 to 240 VAC (50/60 Hz)
Display Method Negative LCD (backlit LED), 7-segment digital display
Character Heights PV: 14.2 mm (Green/Red change); SV: 4.9 mm (Green)
Ambient Operating Temperature -10 to 55 degC (with no icing or condensation)
Ambient Operating Humidity 25% to 85% RH
Storage Temperature -25 to 65 degC (with no icing or condensation)
Base Unit Weight 0.3 kg
Shipping Weight (Calculated) 1.5 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The K3HB-HTA serves as the primary base unit for temperature indication in the K3HB lineup. It is critical to note that optional output boards (such as relay outputs, transistor outputs, or linear current/voltage outputs) are sold separately. Ensure that any expansion card added to the rear slots matches the physical slot designation (Slot A, B, C, D, or E) specified in the system design. When retrofitting legacy K3HN series panels, verify overall depth specifications, as the K3HB series requires a different rear panel depth clearance depending on the terminal covers used.

Application Pitfalls & Engineering Notes

In multi-unit, side-by-side installations, thermal build-up inside closed control cabinets can affect measurement stability. If multiple units are mounted horizontally adjacent without gaps, the maximum ambient operating limit of 55 degC should be derated. Ensure clean ventilation flow across the top and bottom of the instrument chassis to prevent internal reference junction compensation drift.

Commissioning & Wiring Tips

When wiring thermocouple inputs to the TA terminal block, never use copper extension wires; always use correct compensation cables matching the thermocouple type. Keep sensor lines physically separated from high-power distribution lines, variable frequency drive output cables, and inductive switching lines to mitigate electromagnetic noise and reading fluctuations. Ground the shielding of the sensor cable at a single point to prevent ground loop currents.

Installation Guidelines

CRITICAL WARNING

Ensure all main power sources to the panel are completely de-energized and locked out before attempting installation, removal, or terminal wiring. Contact with the 100-240 VAC supply lines can result in severe electrical shock, equipment damage, or personal injury.

1
Prepare a standard 1/8 DIN cutout (92 mm x 45 mm) in the panel fascia. Ensure the panel thickness is within the range of 1 mm to 5 mm.
2
Ensure the watertight packing gasket is properly seated around the front bezel before sliding the K3HB-HTA unit into the panel cutout.
3
Slide the mounting fixture adapter onto the unit housing from the rear, tightening the securing screws evenly to achieve a reliable NEMA 4X / IP66 front-panel seal. Do not overtighten.
4
Terminate wiring onto the screw terminal blocks on the rear, following the diagram for the TA sensor configuration. Ensure terminal screw torque remains within 0.43 to 0.58 Nm.
Loading product navigation…

Can the Omron K3HB-HTA be used directly as a temperature controller?

The K3HB-HTA is a base indicator unit. While it displays temperature and can trigger relay or transistor outputs via optional expansion cards, it does not feature an onboard PID control loop. It is primarily designed for high-visibility indication and signal transmission.

Which thermocouple and RTD sensors are compatible with this unit?

This model features a TA input sensor code, allowing direct connection to Platinum-resistance thermometers (Pt100) and standard thermocouples including types K, J, T, E, L, U, N, R, S, B, and W.

How does the dual-color display function during alarms?

The negative LCD features a PV display that can be programmed to change color between red and green based on threshold values, providing immediate visual warning of out-of-limit process states.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jepun

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...