Description

Integrating high-resolution thermal tracking directly into Sysmac automation systems, the Omron NX-TS2204 provides dual-channel resistance temperature detector monitoring for high-precision industrial processes. Operating on the high-speed NX bus architecture, this module supports three-wire Pt100 and Pt1000 sensors with a rapid conversion speed of 60 ms per unit and an exceptional measurement resolution of 0.001 degC. Designed to maintain signal integrity in electrically noisy environments, it incorporates channel-to-channel and channel-to-bus galvanic isolation via built-in power transformers and digital signal isolators.

Features

  • Dual-point input configuration supporting standard three-wire Pt100 and Pt1000 RTD sensors.
  • Ultra-fine processing resolution of 0.001 degC maximum for sensitive process control applications.
  • Free-Run refreshing method ensures asynchronous, continuous temperature updates independent of task cycles.
  • High-density 12 mm wide form factor saves valuable panel space on standard DIN rail mounting.
  • Screwless clamping terminal block featuring 16 points for fast, secure, gas-tight field wiring.
  • Advanced isolation barriers between input channels and internal NX bus circuitry to prevent ground loop interference.

Applications

  • Multi-zone thermal control in plastic extrusion, injection molding, and thermoforming equipment.
  • Environmental chamber monitoring and high-accuracy industrial drying processes.
  • Pasteurization and cooking systems within food, beverage, and packaging lines.
  • Cleanroom ambient environmental logging and semiconductor fabrication HVAC monitoring.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Omron
Model Number NX-TS2204
Product Type Temperature Input Unit (Resistance Thermometer)
Number of Inputs 2 points
Supported Temperature Sensors Pt100 (three-wire), Pt1000 (three-wire)
Conversion Time 60 ms per Unit
Resolution 0.001 degC max.
I/O Refreshing Method Free-Run refreshing
External Connection Terminals Screwless clamping terminal block (16 terminals)
Input Conversion Range +/-20 degC of the input range
Input Detection Current Approx. 0.25 mA
Conductor Resistance Effect 0.06 degC/Ohm max. (up to 20 Ohms max.)
Warm-up Period Requirement 30 minutes
Isolation Method Power: Transformer; Signal: Digital Isolator (Input-to-bus & Channel-to-channel)
Insulation Resistance 20 MOhms min. between isolated circuits (at 100 VDC)
Dielectric Strength 510 VAC between isolated circuits for 1 minute (leakage current 5 mA max)
NX Unit Power Consumption 0.90 W max. (on CPU Unit); 0.75 W max. (on Communications Coupler)
I/O Power Supply Method No external I/O power supply required
Dimensions (W x H x D) 12 x 100 x 71 mm
Unit Weight 0.07 kg
Shipping Weight 1.00 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The NX-TS2204 is a highly specialized RTD input unit. If your system relies on thermocouple inputs rather than resistance thermometers, the NX-TS2101 or NX-TS2102 should be selected instead. Ensure your Sysmac Studio software is updated to match the firmware revision of your NX-series CPU or communications coupler to guarantee full parameter configuration capabilities.

Application Pitfalls & Engineering Notes

A warm-up period of 30 minutes is strictly required after turning on the power supply to ensure the internal components reach stable thermal equilibrium. Accurate temperature monitoring depends on balanced conductor resistances; an unbalance between the three wires of the RTD sensor will lead directly to temperature measurement drift, adding a maximum of 0.06 degC per Ohm of resistance discrepancy.

Commissioning & Wiring Tips

Always route the sensor cables through dedicated low-voltage instrument trays separate from high-power AC lines. We recommend grounding the shielded sheath of your RTD cables at a single point near the module to avoid circulating currents and shield noise coupling. Double check that the terminal pins are inserted with a proper crimped ferrule for optimal long-term contact in high-vibration panels.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL SHOCK AND SYSTEM DAMAGE

Isolate all electrical power sources supplying the PLC rack and the input devices before inserting, removing, or wiring any NX module. Failure to de-energize the entire control system can lead to unexpected machine movement, electrical shock, or permanent damage to the NX backplane communication circuit.

1

Mount the module onto the DIN rail by aligning the upper hook of the unit with the rail and pressing down until the lock clicks securely into position.

2

Wire the three-wire Pt100/Pt1000 sensors into the screwless clamping terminal block by inserting a flat-blade tool into the release hole, inserting the wire, and removing the tool to lock.

3

Power up the system and monitor the "TS" indicator on the front panel: a solid green light indicates normal operating status, while red indicators flash to signal diagnostic errors such as wire breaks or sensor short circuits.

Loading product navigation…

What sensor types are supported by this temperature input module?

This module supports standard three-wire Pt100 and Pt1000 RTD sensors across both input channels, offering configurable sensor types per channel in the programming environment.

Does this module require an external I/O power supply?

No, it does not require or consume external I/O power. It is powered entirely through the internal NX bus connection, drawing a maximum of 0.90 W when connected to an NX CPU Unit.

What is the measurement resolution and temperature conversion speed?

The module features an ultra-precise measurement resolution of 0.001 degC max. with a high-speed temperature input conversion rate of 60 ms per unit.

How does the Free-Run refreshing method work on this module?

The Free-Run refreshing method performs continuous, asynchronous temperature conversions independently of the controller's main program cycle, providing the latest temperature data on-demand.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jepun

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...