1 daripada 1

ProSoft PLX31-MBTCP-MBS4 Modbus TCP/IP to Modbus Serial 4 Port Gateway

ProSoft PLX31-MBTCP-MBS4 Modbus TCP/IP to Modbus Serial 4 Port Gateway

Hanya 10 item tinggal dalam stok
  • Pengilang: ProSoft

  • No. Produk: PLX31-MBTCP-MBS4

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Protocol Gateways

  • Pembayaran: T/T, Western Union

  • Berat: 2500g

  • Dimensi: 13.67 x 5.05 x 11.13 cm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Facilitating seamless bidirectional communication between Ethernet and serial-based field networks, the ProSoft PLX31-MBTCP-MBS4 acts as a robust protocol converter for industrial automation systems. This module enables a Modbus TCP/IP client or server to interface directly with up to four independent Modbus Serial networks, bridging the gap between legacy serial instruments and modern Ethernet control architectures. Engineered for high-reliability environments, it provides galvanic isolation on all communication paths and features a rugged, compact enclosure designed for DIN-rail mounting. With integrated diagnostics, a flexible power supply input, and individual port configuration, this gateway ensures low-latency data transmission across diverse factory automation, water treatment, and power distribution infrastructures.

Features

  • Independent Serial Ports: Four fully isolated serial ports supporting RS-232, RS-422, or RS-485 physical layers.
  • High Electrical Isolation: 2500 Vrms port-to-port and port-to-backplane signal isolation via digital RF modulation components.
  • Robust Ethernet Interface: Single 10/100 Mbps RJ45 port featuring 1500 Vrms electrical isolation and integrated broadcast storm resiliency.
  • Flexible Power Input: Accepts a wide input range of 10 to 36 VDC, suitable for standard industrial 24 VDC control panels.
  • Diagnostic Indicators: Front-panel LEDs provide immediate visual confirmation of power, module status, network activity, and serial transmission (TX/RX) status.

Applications

  • Integration of legacy Modbus RTU/ASCII power meters, flowmeters, and protection relays into modern Ethernet-based SCADA systems.
  • Substation automation where high electrical isolation is necessary to prevent ground loops and protect centralized controller CPUs.
  • Distributed water and wastewater monitoring setups requiring multi-point RS-485 serial networks linked to a centralized PLC over fiber or wireless Ethernet.

Technical Specifications

Manufacturer ProSoft Technology
Model Reference PLX31-MBTCP-MBS4
Power Supply Input 24 VDC nominal (10 to 36 VDC permitted)
Current Consumption 300 mA @ 24 VDC nominal (610 mA maximum @ 10 VDC)
Ethernet Port 1x 10/100 Base-T RJ45 connector, half/full-duplex auto-negotiation
Ethernet Isolation 1500 Vrms (50 to 60 Hz for 60 seconds)
Serial Interface Ports 4x isolated serial ports (RS-232, RS-422, or RS-485 configuration)
Serial Port Isolation 2500 Vrms signal isolation (UL 1577 rated, RF modulation media)
Operating Temperature -25 to 70 degC (-13 to 158 degF)
Storage Temperature -40 to 80 degC (-40 to 176 degF)
Relative Humidity 5% to 95% RH (non-condensing)
Shock Rating IEC 60068-2-27: 15G operational (11ms), 30G non-operational (18ms)
Vibration Rating IEC 60068-2-6: 5G @ 10 to 150 Hz
Dimensions (H x W x D) 13.67 x 5.05 x 11.13 cm
Shipping Weight 2.5 kg

Connections and Interfaces

Port / Terminal Block Interface Type Functional Assignment
Ethernet Port RJ45 Modbus TCP/IP Master (Client) / Slave (Server) connection
Serial Port 1 to 4 Combicon Terminal Modbus RTU/ASCII Master or Slave (RS-232, RS-422, or RS-485 configuration)
Power Terminal 3-Position Pluggable V+ (10 to 36 VDC), V- (DC Return), and Earth Ground

Empirical Engineering Insights

Alternative Models & Compatibility

The PLX31-MBTCP-MBS4 serves as a modernized replacement for older legacy gateways. When transitioning configuration profiles from previous-generation ProSoft modules, verify database memory mappings, as the internal database register structures may require offset realignment. Use the ProSoft Configuration Builder (PCB) software for smooth parameter migration.

Application Pitfalls & Engineering Notes

A common issue during multi-port commissioning is Modbus TCP/IP transaction timeouts caused by slower serial-side responses. Ensure that your Modbus TCP master poll timeout matches the longest potential serial round-trip time. When running RS-485 configurations with high slave counts or long cable distances, external 120-ohm termination resistors must be installed at both physical ends of the trunk to prevent signal reflections.

Commissioning & Wiring Tips

The four serial interfaces feature specialized 2500 Vrms digital isolation chips. To maintain this high level of isolation performance, never share common reference or shield lines between different isolated ports or external power sources. For noisy VFD environments, utilize double-shielded twisted-pair (STP) cabling for all serial trunks and tie the cable shields directly to the cabinet ground at a single, centralized point.

Installation Guidelines

CRITICAL WARNING: De-energize all power lines before attempting to install, wire, or remove the gateway module. Touching live electrical terminations can lead to severe equipment damage, electrical shock, or physical injury. Ensure the internal system ground terminal is properly bonded to a low-impedance earth ground path before applying DC power.
1
Mount the gateway securely to an approved 35 mm DIN rail inside a protective NEMA or IP54 electrical enclosure, allowing at least 2 inches of clearance at the top and bottom for natural convective cooling.
2
Configure the internal physical serial port jumpers (underneath the front cover) to choose between RS-232, RS-422, or RS-485 modes for each of the four serial ports.
3
Connect the isolated serial network cables to the corresponding pluggable Combicon terminal blocks, ensuring correct polarity of Transmit (TX) and Receive (RX) lines.
4
Connect the Ethernet network cable to the RJ45 port and apply nominal 24 VDC power to the power supply terminal block. Monitor the LED diagnostic indicators to confirm successful module initialization.
Loading product navigation…

Can each serial port run on different communication settings?

Yes. Each of the four serial ports on this module is completely independent. You can configure individual baud rates, parity, stop bits, and physical modes (RS-232, RS-422, or RS-485) per port.

How do you set the IP address of this gateway?

The IP address is set using the ProSoft Configuration Builder (PCB) software over Ethernet, or via the ProSoft Discovery Service utility to detect and assign a static IP address to the module on the local network.

What software is needed to map Modbus TCP/IP registers to Modbus Serial?

No programming is required. Drag-and-drop configuration and custom register mapping are fully handled through ProSoft Configuration Builder (PCB), which is free to download.

Is external termination required for the RS-485 serial networks?

Yes. While the serial ports are isolated, they do not include internal software-selectable termination. For long cable lengths or high noise environments, external 120-ohm resistors must be used at the physical ends of the line.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...