1 of 1

Siemens 6ES7716-1CA00-0BB2 SIMATIC Field PG M4 Premium Programming Device

Siemens 6ES7716-1CA00-0BB2 SIMATIC Field PG M4 Premium Programming Device

Only 3 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7716-1CA00-0BB2

  • Country of origin:Jerman

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.50 cm x 30.00 cm x 17.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Siemens 6ES7716-1CA00-0BB2 is a SIMATIC Field PG M4 Premium industrial programming device designed for automation engineering tasks. This unit features an Intel Core i5-3320M processor with a base clock of 2.6 GHz, capable of boosting up to 3.3 GHz, and is equipped with 8 GB of RAM. For storage, it includes a 300 GB SATA solid-state drive (SSD) and an HD Graphic 4000 for display output. The device boasts a 15.6-inch HD Ready display (1366x768 resolution) and a QWERTY keyboard with German layout options. It comes pre-installed with Windows 7 Ultimate SP1 (64-bit) in multiple languages (EN/DE/FR/SP/IT) and includes a DVD RW optical drive. An MPI cable is supplied, and the unit is noted to be without an S5 interface or S5-EPROMMER. It supports specific software versions under license, such as STEP7 PROF COMBO (V13/2010), WinCC Advanced COMBO (V13/WinCC Flexible 2008), and STEP 7 Micro/WIN V4.0, with an MPI cable software version V12.0.1.0.

Features

  • Intel Core i5-3320M Processor (2.6 GHz, up to 3.3 GHz with Turbo Boost)
  • 8 GB RAM
  • 300 GB SATA Solid-State Drive (SSD)
  • 15.6-inch HD Ready Display (1366x768)
  • HD Graphic 4000
  • DVD RW Optical Drive
  • Windows 7 Ultimate SP1, 64-bit (EN/DE/FR/SP/IT)
  • QWERTY Keyboard (& German layout)
  • Includes MPI Cable
  • Without S5 Interface and S5-EPROMMER

Applications

The SIMATIC Field PG M4 Premium is suitable for a range of industrial automation applications, including:

  • Programming and configuration of Siemens SIMATIC PLCs and HMIs.
  • On-site diagnostics and troubleshooting of automation systems.
  • Development and commissioning of industrial control applications.
  • Mobile engineering tasks in manufacturing, process, and infrastructure environments.

Technical Specifications

Attribute Value
Manufacturer Siemens
Brand Siemens
Range Simatic Field PG
Subrange Field PG M4
Product Type Premium Programming Device
PLM Product Phase Phase-Out
Processor Intel Core i5-3320M (3 M Cache, 2.6 GHz, up to 3.3 GHz with Turbo Boost)
RAM 1x 8GB
Storage 300 GB SATA Solid-State Drive (SSD)
Graphics HD Graphic 4000
Display Size 15.6 inches
Display Resolution HD Ready (1366x768)
Optical Drive DVD RW
Operating System Windows 7 Ultimate SP1, 64 Bit (EN/DE/FR/SP/IT)
Keyboard Layout QWERTY (& German)
S5 Interface Without
S5-EPROMMER Without
Included Cable Line cable for: DE, FR, NL, SP, BEL, OES, SWD, FIN; MPI Cable
MPI Cable Software Version V12.0.1.0
Shipping Weight 3.50 kg
Package Dimensions (Calculated) 39.50 cm x 30.00 cm x 17.00 cm
Commodity Code 84713000
Export Control Regulations (ECCN) N
Country of Origin Unknown

Installation Guidelines

  1. Unpacking and Inspection: Carefully unpack the SIMATIC Field PG M4 and inspect for any physical damage. Retain original packaging for potential future transport.
  2. Power Connection: Connect the provided line cable to the Field PG and a suitable power outlet. Ensure the power supply matches the regional specifications for the included cable (DE, FR, NL, SP, BEL, OES, SWD, FIN).
  3. Initial Power-Up: Power on the device. The pre-installed Windows 7 Ultimate SP1 operating system should boot.
  4. Software Installation/Licensing: Note that STEP 5 and STEP 7-Micro/WIN are not pre-installed. STEP 5 is not executable under Windows 7. Ensure proper licensing for compatible software such as STEP7 PROF COMBO (V13/2010), WinCC Advanced COMBO (V13/WinCC Flexible 2008), or STEP 7 Micro/WIN V4.0 before attempting to use them.
  5. Peripheral Connections: Connect the MPI cable for communication with SIMATIC PLCs. Utilize available USB or other ports for additional peripherals as needed.
  6. System Updates: Perform necessary operating system updates and driver installations to ensure optimal performance and security.
  7. Environmental Considerations: Operate the device within a clean, dry environment, avoiding extreme temperatures or direct sunlight to ensure longevity and reliable operation.

What operating system is pre-installed on the SIMATIC Field PG M4?

The device comes with Windows 7 Ultimate SP1, 64-bit, pre-installed in multiple languages (EN/DE/FR/SP/IT).

Is STEP 5 software compatible with this Field PG?

No, STEP 5 is not pre-installed and is not executable under Windows 7, which is the pre-installed operating system on this device.

Does the 6ES7716-1CA00-0BB2 include an S5 interface?

No, this specific model is supplied without an S5 interface and without an S5-EPROMMER.

What type of storage does this Field PG use?

It is equipped with a 300 GB SATA Solid-State Drive (SSD).

What software versions are noted as compatible or executable under license?

The device supports software such as STEP7 PROF COMBO (V13/2010), WinCC Advanced COMBO (V13/WinCC Flexible 2008), and STEP 7 Micro/WIN V4.0 under appropriate licensing.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...