1 z 1

130B1107 Danfoss VLT Series Control Panel LCP 102

130B1107 Danfoss VLT Series Control Panel LCP 102

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 130B1107

  • Country of origin:Stany Zjednoczone

  • Product Type: VLT® Control Panel LCP 102

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Product Overview

The 130B1107 (130B1107) is a high-performance VLT Control Panel LCP 102 designed specifically for the Danfoss VLT AutomationDrive series. As the primary human-machine interface (HMI), this graphical control unit provides seamless interaction with frequency converters in demanding industrial environments such as wastewater treatment plants, HVAC systems, and chemical processing facilities. By enabling real-time monitoring and rapid parameter adjustments, the 130B1107 minimizes system commissioning time and reduces critical downtime. Its robust design ensures reliable data visualization and diagnostics, allowing engineers to maintain optimal motor control and energy efficiency across complex automated architectures.

Technical Configuration

The VLT Control Panel LCP 102 is engineered with a multi-language graphical display that supports a wide array of international character sets. It features a hot-plug capability, allowing operators to attach or remove the panel during drive operation without interrupting the power supply. The unit integrates a built-in copy function, enabling the storage of up to five different sets of parameter data, which simplifies the cloning of settings across multiple drives. The hardware interface includes dedicated navigation keys and a status LED array for immediate fault identification. It is designed to meet IP66 ingress protection ratings when mounted in a remote door kit, ensuring resilience against dust and high-pressure water jets in wash-down areas.

Technical Specifications

Attribute Specification Details
Model 130B1107
Brand Danfoss
Product Series VLT AutomationDrive FC 102 / 202 / 301 / 302
Display Type Graphical LCD with Backlight
Origin Denmark / EU
Net Weight 0.5 kg
Shipping Weight 1.5 kg
Operating Temp -10 to 50 deg C
Storage Temp -20 to 65 deg C
Protection Rating IP66 (Front side when mounted)
Communication Plug-and-Play RS-485 Interface

Technical FAQs

Does the 130B1107 support the transfer of parameters between different power sizes?

Yes, the LCP 102 can store parameter sets from one drive and download them to another, provided the drives belong to the same VLT series. However, motor-specific data should be verified after transfer.

How can I troubleshoot a blank display when the drive is powered on?

Check the physical connection between the LCP and the drive cradle. If using a remote mounting kit, verify the cable length does not exceed 3 meters and ensure there is no electromagnetic interference (EMI) affecting the link.

Is the LCP 102 compatible with the older LCP 101 numerical displays?

The 130B1107 is the graphical upgrade for the VLT series. While it fits the same physical slot as the LCP 101, it offers enhanced diagnostic graphs and full-text descriptions which are not available on the numerical version.


Engineering & Installation Guide

Mounting and Shielding: When installing the 130B1107 in a remote configuration (cabinet door mounting), always use a shielded twisted pair cable for the serial connection. Ensure the shield is grounded at the drive end to prevent signal corruption from high-frequency noise generated by the inverter stages.

Heat Management: While the panel is rated for 50 deg C, prolonged exposure to direct sunlight or high-intensity UV rays can degrade the LCD contrast over time. In outdoor installations, use a protective weather shield or a tinted transparent cover to extend the service life of the display.

Firmware Synchronization: Before performing a "Copy to LCP" operation for mass commissioning, ensure the drive firmware version is compatible with the LCP 102 software revision. Mismatched versions may result in "Parameter Error" notifications during the upload/download process.

 

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Czarny
Country of origin
Stany Zjednoczone
Power source
Zasilanie prądem stałym

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...