Description

The REF615 is a dedicated feeder protection and control relay designed for the protection, control, measurement and supervision of utility substations and industrial power systems. As part of the ABB Relion 615 series, this device provides standard configuration C, which is specifically tailored for applications requiring comprehensive overcurrent and earth-fault protection with additional voltage and frequency measurement capabilities. The REF615 integrates numerical protection functions, local human-machine interface (LHMI) displays, programmable light-emitting diodes (LEDs), and extensive communication capabilities into a single compact unit. It supports native implement of the IEC 61850 standard for communication in substations, as well as Modbus TCP/IP, Modbus RTU, DNP3, and Profibus using optional communication modules. The relay handles current and voltage inputs via instrument transformers, executing real-time monitoring and trip logic to ensure the stability and safety of distribution networks.

Features

  • Complete overcurrent and directional/non-directional earth-fault protection for distribution feeders.
  • Integrated voltage and frequency protection functions for grid stability and load shedding.
  • Support for parallel redundancy protocol (PRP) and high-availability seamless redundancy (HSR).
  • Native IEC 61850 implementation including horizontal GOOSE messaging for fast inter-relay interlocking.
  • Web human-machine interface (WHMI) enabling secure remote access via a standard web browser.
  • Built-in trip-circuit supervision (TCS) and continuous self-supervision of hardware and software.
  • Flexible graphical configuration using the Protection and Control IED Manager PCM600 tool.

Applications

  • Utility distribution substations.
  • Industrial power distribution systems.
  • Main and feeder protection for medium-voltage networks.
  • Backup protection for power transformers and high-voltage transmission lines.
  • Load shedding and grid integration of distributed generation.

Technical Specifications

Parameter Specification
Manufacturer ABB
Product Series Relion 615 series
Model REF615 Standard Configuration C (REF615-C)
Rated Frequency 50 / 60 Hz
Current Inputs 4 (3 phase + residual)
Voltage Inputs 3 or 5 (depending on explicit variant configuration)
Communication Protocols IEC 61850, Modbus TCP/IP, Modbus RTU, DNP3, Profibus
Local Interface LCD, 3 LEDs (Protection indicators), 11 Programmable LEDs
Configuration Software PCM600 Protection and Control IED Manager
Approximate Weight 3.5 kg
Dimensions (W x H x D) 177 mm x 177 mm x 201 mm

Installation Guidelines

Panel Mounting

The relay must be mounted securely into a cutout panel using the provided mounting brackets and screws. Ensure proper clearance is maintained around the rear enclosure to facilitate adequate natural cooling and air ventilation.

Grounding and Shielding

Connect the dedicated grounding terminal on the rear of the device chassis directly to the substation earth bar using a heavy-gauge copper wire. All communication cables, especially serial links like RS-485 and Ethernet copper lines, must use high-quality shielded twisted-pair (STP) cables with the shields grounded properly to minimize electromagnetic interference (EMI).

Cable Routing and Termination

Separate low-voltage signal wires and communication cables from high-voltage primary current transformer (CT) and voltage transformer (VT) secondary wiring. Ensure all binary inputs and signal outputs are terminated correctly according to the connection diagram provided with standard configuration C, verifying correct polarity for all DC auxiliary supply lines.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB REF615 Standard Configuration C Feeder Protection and Control

How can the configuration of the REF615 relay be modified?

The engineering, parameterization, and graphical configuration of the relay are performed using the PCM600 Protection and Control IED Manager software.

What communication interfaces are supported on the rear panel?

Depending on the specific hardware options selected, the rear panel supports RJ-45 galvanic Ethernet, LC fiber optic Ethernet, RS-485 serial, and glass fiber serial interfaces.

What function does the integrated Web HMI provide?

The WHMI allows authorized personnel to securely view measurements, event lists, disturbance records, and status information using a standard web browser.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Szaro-biały
Country of origin
Szwecja

Ostatnio oglądane produkty

Wiedza techniczna

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...