1 z 1

ABB S282UC-K2 GHS2820164R0277 S280UC Miniature Circuit Breakers MCBs

ABB S282UC-K2 GHS2820164R0277 S280UC Miniature Circuit Breakers MCBs

  • Manufacturer: ABB

  • Product No.: S282UC-K GHS2820164R0277

  • Country of origin:Szwecja

  • Product Type: Miniature Circuit Breakers

  • Payment: T/T, Western Union

  • Weight: 240g

  • Dimensions: 90 mm x 85 mm x 35 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

The S282UC-K2 universal current miniature circuit breaker with Product ID GHS2820164R0277 is a 2-pole electrical device engineered to deliver comprehensive current limitation, short-circuit protection, and overcurrent mitigation. As part of the S280UC product series, this unit features a delayed thermal tripping mechanism for overload protection and an electromechanic magnetic tripping mechanism for short circuit protection. It is specifically optimized with a high DC voltage rating to serve as a reliable solution for direct current sub-circuits up to 440 V DC across two poles, making it highly compatible with applications in photovoltaics, telecommunication infrastructure, electric traction setups, and specialized industrial settings.

Features

  • Equipped with a 2-pole hardware architecture supporting multi-line configuration protection.
  • Utilizes a K-characteristic tripping curve designed to handle specific inductive current parameters.
  • Features a universal current architecture certified for both alternating current and high-voltage direct current distribution.
  • Incorporates an insulation group I housing finished in RAL 7035 with a sealable black insulation group II actuator handle.

Applications

  • Photovoltaic power string arrays and solar combiner panel boxes.
  • Telecommunication power backup networks and traction sub-stations.
  • Industrial direct current control circuits requiring specialized branch circuit overcurrent protection.

Ordering Information

Parameter Value
Extended Product Type S282UC-K2
Product ID GHS2820164R0277
EAN 4012233652808

Technical Specifications

Parameter Specification
Manufacturer ABB
Product ID GHS2820164R0277
Extended Product Type S282UC-K2
Number of Poles 2
Tripping Characteristic K
Rated Current 2 A
Rated Ultimate Short-Circuit Breaking Capacity (Icu) 6.0 kA
Pollution Degree 2
Rated Impulse Withstand Voltage (Uimp) 4 kV (6.2 kV at sea level, 5.0 kV at 2000 m)
Dielectric Test Voltage 50/60 Hz, 1 min.: 2 kV
Housing Material Insulation group I, RAL 7035
Actuator Type Insulation group II, black, sealable
Actuator Marking I / O
Contact Position Indication ON / OFF
Degree of Protection IP20 (IP40 inside an enclosure with cover)
Electrical Endurance (Nelec) 10000 cycle
Mechanical Endurance (Nendu) 20000 cycle
Terminal Type Screw Terminals
Screw Terminal Type Cable Clamp
Connecting Capacity Rigid 0.75 ... 25 mm² / Flexible with Ferrule 0.75 ... 16 mm²
Tightening Torques 2.5 N-m
Recommended Screw Driver Pozidriv 2
Maximum Operating Voltage UL/CSA 500 V DC / 480 V AC

Installation Guidelines

  • DIN Rail Installation: Secure the unit onto standard symmetrical tracks including TH35-7.5 (35 x 7.5 mm mounting rail) or TH35-15 (35 x 15 mm mounting rail) in compliance with IEC 60715.
  • Mounting Position: The mechanical frame allows assembly at any functional orientation angle.
  • Polarity Tracking: Ensure specific attention is paid to the verified polarity markings of the device during direct current circuit wire placement.
  • Terminal Connections: Connect conductors tightly to the integrated cable clamp screw terminals using a Pozidriv 2 tool to ensure a torque of 2.5 N-m.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB S282UC-K2 GHS2820164R0277 S280UC Miniature Circuit Breakers MCBs

What makes this breaker suitable for direct current installations?

The device features a high direct current rating up to 440 V DC across 2 poles and utilizes optimized breaking capabilities for photovoltaic and telecommunication networks.

What is the certified tightening torque for wire installation on this device?

The integrated cable clamp screw terminals must be tightened to a verified torque rating of 2.5 N-m.

What are the mechanical and electrical endurance capacities of the device?

The device is specified to survive 10000 electrical endurance cycles and up to 20000 mechanical operational cycles.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Szwecja

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...