1 z 1

B&R X20CM0985 X20 System 3-Phase Energy Measurement Module

B&R X20CM0985 X20 System 3-Phase Energy Measurement Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20CM0985

  • Country of origin:Stany Zjednoczone

  • Product Type: Analog inputs

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Product Overview

The X20CM0985 (X20CM0985) is a sophisticated 3-channel analog input module designed for comprehensive power and energy measurement within the B&R X20 System. This module is engineered to monitor 3-phase electrical networks, supporting direct voltage inputs of up to 480 VAC and current inputs of 1 A or 5 A AC via external transformers. In energy-intensive industries such as plastics processing, metal fabrication, and large-scale manufacturing, the X20CM0985 provides the critical data required for load management, predictive maintenance, and energy efficiency auditing. By delivering high-precision measurements of active, reactive, and apparent power directly to the PLC, it enables engineers to optimize machine performance and reduce operational overhead through real-time grid analysis.

Technical Configuration

The X20CM0985 integrates complex signal processing within the standard X20 form factor. It features three independent channels for simultaneous current and voltage measurement, allowing for the calculation of phase angles and harmonic distortion. The internal hardware is robust, consuming 1.05 W from the X20 bus and 4 W for the internal I/O circuitry. It is designed for high-voltage environments with a rated input capacity of 120 VAC to 480 VAC, making it compatible with most global industrial power grids. The module utilizes specialized A/D converters to handle the AC waveforms, ensuring that peak values and RMS calculations are performed with minimal latency. With an IP 20 protection rating, it is intended for installation in controlled electrical cabinets where space-saving and modularity are prioritized.

Technical Specifications

Feature Specification
Model X20CM0985
Brand B&R (Bernecker + Rainer)
Module Type Analog Input / Energy Measurement
Number of Channels 3 (Current and Voltage)
Voltage Input Range 120 VAC to 480 VAC
Current Input Range 1 A or 5 A AC
Bus Power Consumption 1.05 W
Internal I/O Consumption 4 W
Degree of Protection IP 20
Operating Temp 0 to 55 deg C
Dimensions 12.5 x 99 x 75 mm
Shipping Weight 2.0 kg

Technical FAQs

Can the X20CM0985 measure power in both 3-phase and single-phase systems?

Yes, the module is designed for 3-phase systems but can be configured to monitor three individual single-phase circuits. This flexibility allows for the monitoring of multiple high-load single-phase actuators within a single machine using only one module.

Does this module require external current transformers (CTs)?

Yes, for current measurement, the X20CM0985 must be interfaced with external current transformers that provide a secondary output of either 1 A or 5 A AC. Direct connection of high-current power lines to the module will result in immediate hardware failure.

What specific electrical parameters can be calculated by the X20CM0985?

Beyond standard voltage and current, the module provides data for active power (W), reactive power (var), apparent power (VA), energy consumption (Wh), and power factor (cos phi). It also supports frequency measurement and basic harmonic analysis.


Engineering & Installation Guide

  • Current Transformer Polarity: When wiring the 1 A or 5 A current inputs, strict adherence to the S1 (k) and S2 (l) polarity is essential. Reversing the polarity on a single phase will result in incorrect power factor readings and negative energy calculations for that specific phase.

  • Voltage Path Protection: Always install 3-pole circuit breakers or fuses (typically rated at 1 A to 2 A) in the voltage measurement path between the power line and the X20CM0985. This protects the module and the X20 backplane from catastrophic failure in the event of a line-to-line short circuit within the measurement loop.

  • Shielding and Grounding: Given the proximity to high-voltage lines, the X20CM0985 is susceptible to electromagnetic interference. Ensure the X20 bus module is properly snapped onto a grounded DIN rail. Use shielded cables for the current transformer secondaries and ground the shield at a single point to prevent circulating ground currents from skewing measurement accuracy.

 

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Szaro-biały
Country of origin
Stany Zjednoczone
Power source
Zasilany prądem zmiennym

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...