Beckhoff CX2550-0179 CX2000 Series USB Extender Transmitter Module

Beckhoff CX2550-0179 CX2000 Series USB Extender Transmitter Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX2550-0179

  • Country of origin:Niemcy

  • Product Type: USB Extender Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 24 mm x 99 mm x 54.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

Providing extended local system expansion directly from the CX2000 Embedded PC series, the Beckhoff CX2550-0179 functions as a high-reliability transmitter module for USB signals. This unit transmits USB 1.1 data packets over extensive plant floor runs, facilitating a secure link between the central processor and a remote operator interface such as the CP69xx-xxxx-0000 series control panels. By utilizing the proprietary USB Extended technology, it eliminates the need for active signal repeaters while maintaining deterministic communication.

Key Features

  • Direct physical and electrical integration with the left-side system connection of CX20xx Embedded PCs.
  • Transmission of USB 1.1 signals up to a maximum distance of 50 meters.
  • Utilizes standard, cost-effective Cat.5E shielded twisted-pair cabling for physical transport.
  • Integrated RJ45 connection socket designed for high mechanical retention in high-vibration panels.
  • Zero-configuration operation via system bus power routing, requiring no external power supply wiring.
  • Four diagnostic LEDs providing direct status visibility for Power, Speed, +15 V, and Suspend states.

Applications

  • Decentralized visualization panels (CP69xx-xxxx-0000) mounted on machine swing arms.
  • Remote human-machine interfaces (HMI) located away from high-noise electrical cabinets.
  • Long-range peripheral configuration and diagnostic ports in assembly lines.

Technical Specifications

Specification Parameter Value / Details
Manufacturer Beckhoff Automation
Model Number CX2550-0179
Interface Type 1 x USB Extended 1.1 Transmitter
Physical Connection RJ45 Shielded Socket
Transmission Distance Max. 50 m via Cat.5E cable
Power Supply Via system bus (powered through CX2100-0xxx power supply modules)
LED Diagnostics 1 x Power, 1 x Speed, 1 x +15 V, 1 x Suspend
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Dimensions (W x H x D) 24 mm x 99 mm x 54.5 mm
Net Weight 190 g
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Empirical Engineering Insights

Alternative Models & Compatibility

The CX2550-0179 is designed exclusively as a USB 1.1 transmitter. If your target peripheral or remote HMI requires USB 2.0 speeds (e.g., for external storage, heavy file transfers, or modern touch controllers requiring USB 2.0 bandwidth), the CX2550-0079 should be used instead. Note that the transmitter module must always match the capability of the receiver card built into the CP69xx control panel series.

Application Pitfalls & Engineering Notes

When calculating thermal dissipation inside compact, unventilated electrical cabinets, factor in the 190 g modules continuous heat output alongside the main CX CPU module. To ensure consistent signal integrity, avoid parallel routing of the Cat.5E connection cable with high-voltage AC motor drives or heavy contactor supply lines. While the unit complies with EN 61000-6-2 industrial immunity standards, severe electromagnetic fields can trigger transient packet drops, causing the 'Suspend' LED to toggle.

Commissioning & Wiring Tips

Always utilize STP (Shielded Twisted Pair) Cat.5E cabling with fully metal-shielded RJ45 plugs. Ensure the metal shielding on the cable makes direct contact with the grounding shroud of the RJ45 socket on both the CX2550-0179 transmitter and the receiver unit. If the grounding path is compromised, electrostatic build-up may cause communication interruptions or require a cold reboot of the CX20xx controller.

Installation Guidelines

CRITICAL WARNING:

Do not install or remove the CX2550-0179 transmitter module while the central control system is powered. Ensure the primary CX2100-0xxx power supply module is completely de-energized and wait at least 30 seconds for all residual capacitance to bleed down before mechanical mounting. Failure to comply can result in permanent damage to the multi-pin PC/104 system bus interface.

1
Disconnect all power from the main control panel and verify that the system is safe to touch.
2
Align the CX2550-0179 guide pins with the left-hand expansion connector of the CX20xx CPU module.
3
Press the two units together gently until the locking mechanism fully clicks, verifying a gap-free fit.
4
Insert the shielded Cat.5E patch cable into the RJ45 port until it locks in place, ensuring the cable strain relief is secure.
5
Re-energize the power supply module. Confirm the Power and diagnostic LEDs light up, indicating communication initialization with the TwinCAT platform.

What is the maximum cable distance supported by the CX2550-0179?

The CX2550-0179 transmitter module supports a maximum transmission distance of up to 50 meters when using a standard high-quality Cat.5E or higher shielded copper Ethernet cable.

Does this module support USB 2.0 or USB 3.0 devices?

No, this module is strictly designed for USB 1.1 protocol rates. For applications requiring USB 2.0 standard bandwidth and speeds, you must utilize the CX2550-0079 module.

Does the CX2550-0179 require a dedicated external power supply wiring?

No, the module is powered directly from the internal system bus of the host controller, drawing its working current through the integrated connection interface of the CX2100 power supply.

What do the diagnostics LEDs indicate on the front panel of the module?

The module features four active status LEDs: 'Power' indicates general internal voltage presence, 'Speed' reflects active data transmission, '+15 V' confirms correct voltage supply to the interface circuitry, and 'Suspend' illuminates when the connected USB device enters low-power standby mode.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...