1 z 1

BECKHOFF EL3403 EtherCAT Terminal 3-Channel Power Measurement Module

BECKHOFF EL3403 EtherCAT Terminal 3-Channel Power Measurement Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3403

  • Country of origin:Niemcy

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 75g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

To analyze three-phase AC power networks directly within the industrial fieldbus segment, the Beckhoff EL3403 provides precise, high-performance measurement values. This 3-channel analog input power measurement terminal is designed to calculate comprehensive electrical grid status parameters, including effective power, reactive power, apparent power, energy consumption, phase angle (cos phi), and frequency for each connected phase. Processing inputs up to 500 V AC directly, the module supports highly detailed diagnostics of energy distribution systems and industrial machinery. Non-intrusive current sensing up to 1 A (AC) is executed through external measuring transformers (such as x A/1 A), enabling flexible integration into existing power distribution frameworks.

Features

  • Mains-synchronous conversion with 16-bit resolution for premium signal acquisition.
  • Direct RMS value calculation for all applied voltage and current waveforms.
  • Comprehensive data calculation: delivers current, voltage, active/reactive/apparent power, energy, frequency, and phase angle values directly over the E-bus.
  • Optional single-phase operation mode for simplified monitoring on isolated lines.
  • Galvanic electrical isolation rating of 1500 V to isolate low-voltage logic from high-voltage measuring points.
  • Compact 12 mm design form factor optimizing space layout on industrial DIN rails.

Applications

  • Real-time energy management and sub-metering in industrial production facilities.
  • Dynamic load monitoring and diagnostic tracking on high-power three-phase AC motors.
  • Integration within power distribution plants and substation cabinets for utility tracking.
  • Predictive maintenance analytics based on power signature variations.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL3403
Technology 3-phase power measurement for alternating voltages
Number of Inputs 3 x current, 3 x voltage
Measuring Voltage Max. 500 V AC 3~ (ULX-N: max. 288 V AC)
Measuring Current Max. 1 A AC (via measuring transformers x A/1 A)
Resolution 1 uA, 0.1 mV, 10 mW (16-bit)
Measuring Error 0.5% relative to full scale value (U/I), 1% calculated values
Measuring Procedure True RMS calculation
Conversion Time Mains-synchronous
Electrical Isolation 1500 V
Current Consumption E-bus Typ. 120 mA
Process Image Bit Width 62 byte PM input, 3 byte PM output
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Enclosure Protection Rating IP20
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 75 g

Connections and Interfaces

Connection Property Specification
Wiring Method Solid conductor (e), flexible conductor (f), and ferrule (a)
Actuation Method Spring actuation by screwdriver
Connection Cross-Section (Solid/Stranded) 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section (With Ferrule) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm
Current Load Power Contacts Max. 10 A

Installation Guidelines

  • Mount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, locking it firmly into place.
  • Ensure double slot and key mechanical connection is completely flush with adjacent terminals.
  • Route high-voltage measurement lines separated from low-voltage E-bus and signal lines to prevent noise coupling.
  • Install appropriate external current transformer shorting blocks for safety during troubleshooting or hardware swap-outs.

Compliance and Certifications

  • CE
  • UL listed
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27

What parameters can the Beckhoff EL3403 calculate and display?

The EL3403 measures voltage, current, effective power, reactive power, apparent power, energy consumption, phase angle (cos phi), and frequency for each of the three channels.

Does the EL3403 support single-phase operation?

Yes, while the terminal is optimized for 3-phase power measurement on AC networks, it also supports optional single-phase configuration.

What is the maximum voltage input direct rating of the EL3403?

The terminal is rated for a maximum measuring voltage of 500 V AC 3-phase (with ULX-N rating at a maximum of 288 V AC).

How is the current measured using this EtherCAT terminal?

The module measures AC current up to 1 A, which is typically routed via external, standard measuring transformers configured as x A / 1 A.

What is the mechanical environmental protection rating of the EL3403?

The terminal has an IP20 protection rating and is designed for cabinet installation on a 35 mm DIN rail.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...