1 z 1

Beckhoff EL4112-0010 EtherCAT Terminal 2-Channel Analog Output Module

Beckhoff EL4112-0010 EtherCAT Terminal 2-Channel Analog Output Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL4112-0010

  • Country of origin:Niemcy

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 65g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

Engineered for precision industrial control loops, the EL4112-0010 analog output terminal generates standard electrical current signals in the range of -10 to +10 mA. This analog output terminal processes process data from the automation device with a high resolution of 16 bits (including sign) and transmits it with galvanic isolation directly to the field level. It features integrated Distributed Clocks (DC) support, allowing for highly synchronized, microsecond-level updates across EtherCAT networks.

The system features a 3-wire, single-ended connection technology, making it compatible with a wide array of industrial actuators, control valves, and system drives. With parameterized watchdog functionality and customizable user synchronization, this module delivers stable performance and safe-state fallback options for critical machinery systems.

Features

  • Provides two independent analog output channels with a current range of -10 to +10 mA.
  • Delivers high-precision digital-to-analog conversion at 16-bit resolution (including sign).
  • Supports EtherCAT Distributed Clocks (DC) with synchronization precision under 1 microsecond.
  • Includes short-circuit-proof outputs compatible with loads up to 500 Ohm.
  • Features integrated parameterizable watchdog state and user-activatable synchronization.
  • Constructed with a compact, rugged housing requiring only 12 mm of DIN rail width.

Applications

  • Closed-loop hydraulic and pneumatic valve positioning
  • Variable speed motor drive control systems
  • Distributed industrial process automation and telemetry
  • Power generation and turbine control auxiliary systems

Technical Specifications

Manufacturer Beckhoff
Part Number / Model EL4112-0010
Number of Outputs 2
Signal Current -10 to +10 mA
Resolution 16 bit (incl. sign)
Connection Technology 3-wire, single-ended
Power Supply 24 V DC via power contacts
Current Consumption E-bus typ. 160 mA
Current Consumption Power Contacts typ. 15 mA + load
Process Image Bit Width 2 x 16 bit AO output
Maximum Output Rate 15 ksps
Load < 500 Ohm (short-circuit proof)
Measuring / Output Error < +-0.1% (relative to end value)
Electrical Isolation 500 V (E-bus / signal voltage)
Distributed Clocks Yes (precision << 1 microsecond)
Housing Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight approx. 65 g
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20

Connections and Interfaces

Connection Type Conductor Cross-Section AWG Range Stripping Length
Solid Wire (s) 0.08 to 2.5 mm² AWG 28 to 14 8 to 9 mm
Stranded Wire (st) 0.08 to 2.5 mm² AWG 28 to 14 8 to 9 mm
With Ferrule (f) 0.14 to 1.5 mm² AWG 26 to 16 8 to 9 mm

Installation Guidelines

  • Mount vertically onto standard 35 mm DIN rails conforming to EN 60715.
  • Ensure lock connection is engaged correctly during side-by-side terminal configuration via the integrated double slot-and-key system.
  • Use a standard screwdriver to actuate the spring-clamp terminals when routing field wiring.
  • Avoid installing in environments exceeding 95% non-condensing relative humidity.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

What is the primary function of the Beckhoff EL4112-0010?

The Beckhoff EL4112-0010 is a 2-channel analog output terminal designed to output precise current signals ranging from -10 to +10 mA with 16-bit resolution.

Does the EL4112-0010 support synchronized EtherCAT operations?

Yes, it supports EtherCAT Distributed Clocks (DC), enabling highly synchronized output updates with a system precision of under 1 microsecond.

What is the maximum current load for the power contacts on this terminal?

The maximum current load capability of the power contacts on the EL4112-0010 is 10 A.

What is the protection rating and mounting method for this device?

The module features an IP20 protection rating and is designed for direct mounting onto standard 35 mm DIN rails (EN 60715).

Is the EL4112-0010 certified for hazardous industrial locations?

Yes, the terminal is ATEX-certified with the marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...