1 z 1

Beckhoff KM1018-0001 Bus Terminal Digital Input Module

Beckhoff KM1018-0001 Bus Terminal Digital Input Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KM1018-0001

  • Country of origin:Niemcy

  • Product Type: Bus Terminal Modules

  • Payment: T/T, Western Union

  • Weight: 310g

  • Dimensions: 123 mm x 100 mm x 55 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

High-density digital signal processing within the Beckhoff I/O system is efficiently managed by the KM1018-0001 Bus Terminal module. This compact 64-channel digital input module is engineered to capture binary control signals from the physical field level and transmit them with electrical isolation to the higher-level K-bus controller. With its high channel density and pluggable wiring configuration, this terminal module significantly reduces control cabinet footprint requirements while maintaining robust signal integrity.

The Beckhoff KM1018-0001 features a fast input filter time of typically 0.2 ms, making it highly suitable for applications demanding rapid state detection. Connection to the field inputs is established via a pluggable 1-wire connector level, enabling easy pre-assembly of the wiring harness and reducing downtime during maintenance. The module integrates seamlessly into standard DIN rail configurations, communicating directly with the process image through a 64-bit width mapping without requiring complex parameterization.

Features

  • 64 digital inputs structured in 8 groups of 8 channels.
  • Fast input filter of typically 0.2 ms for high-speed signal capture.
  • Pluggable 1-wire connection interface simplifies wiring and deployment.
  • Galvanic isolation of 500 V between the K-bus and the field potential.
  • Compact terminal block housing featuring double slot and key alignment for robust mounting.
  • No address settings or software configuration required for standard startup.

Applications

  • High-density electrical cabinet integration.
  • Packaging machinery and automated assembly lines.
  • Multi-axis machine tool automation.
  • Distributed sensor arrays in manufacturing plants.

Ordering Information

Model Number Configuration Connector Included
KM1018-0000 64-channel digital input, 24 V DC, 0.2 ms filter Without pluggable connector
KM1018-0001 64-channel digital input, 24 V DC, 0.2 ms filter 1-wire connector included
KM1018-0002 64-channel digital input, 24 V DC, 0.2 ms filter 1-wire connector with status LEDs
KM1018-0004 64-channel digital input, 24 V DC, 0.2 ms filter 3-wire connector with status LEDs

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Part Number / Model KM1018-0001
Number of Inputs 64 (8 x 8)
Nominal Input Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 to +5 V (conforms to EN 61131-2, type 1)
"1" Signal Voltage 15 to 30 V (conforms to EN 61131-2, type 1)
Input Filter typ. 0.2 ms
Input Current typ. 5 mA
Current Consumption K-Bus typ. 3 mA
Electrical Isolation 500 V (K-bus / field potential)
Bit Width in Process Image 64 inputs
Dimensions (W x H x D) 123 mm x 100 mm x 55 mm
Weight approx. 310 g (including 1-pin connector)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20

Connections and Interfaces

Terminal Interface Function Connection Properties
X1 to X8 Connectors 8 groups of 8 digital inputs Pluggable, 1-wire connection
Wire Cross-Section Solid/stranded conductors 0.08 to 1.5 mm²
Stripping Length Conductor preparation 8 mm

Installation Guidelines

  • Mounting: Attach to a standard 35 mm DIN rail conforming to EN 60715 using the integrated locking tab.
  • Alignment: Place side-by-side with adjacent K-bus terminals using the double slot and key connection points for optimal structural stability.
  • Wiring: Route signals using 1-wire plug connectors. Ensure wire terminations are stripped to exactly 8 mm before terminal insertion.
  • Shielding & Grounding: Ensure the mounting rail is clean, paint-free, and adequately grounded to provide low-impedance pathways for EMC transients.

Compliance and Certifications

  • CE

What is the key difference between the Beckhoff KM1018-0001 and KM1008 modules?

The primary difference lies in the input filter time. The KM1018 series features a typical input filter time of 0.2 ms, whereas the KM1008 series has a slower typical filter time of 3.0 ms.

Does the KM1018-0001 ship with pluggable connectors included?

Yes, the KM1018-0001 variant comes supplied with the pluggable 1-wire connector assembly needed for termination.

What is the process image bit width for this input module?

The KM1018-0001 occupies a bit width of 64 inputs in the system process image.

Is any software addressing required for installation?

No, the module is integrated into the I/O bus automatically and does not require manual address or hardware parameter configuration.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...