1 z 1

DELTA VFD450C43S AC Motor Drive C2000 Series

DELTA VFD450C43S AC Motor Drive C2000 Series

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: VFD450C43S

  • Country of origin:Stany Zjednoczone

  • Product Type: Delta Products AC Drives, C2000 Series

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 25.5cm x 28cm x 50cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Product Overview

The VFD450C43S (VFD450C43S) is a high-capacity, heavy-duty AC motor drive from Delta’s C2000 series, specifically engineered to manage loads up to 45 kW (60 HP) in normal duty applications. Designed for industrial three-phase 460 V power systems, this drive provides the high-torque, precision control required for large-scale industrial infrastructure, such as high-output extrusion lines, large-scale industrial fans, and heavy-duty conveyor systems. The C2000 series is renowned for its advanced Field Oriented Control (FOC) architecture, which provides superior speed and torque regulation to maximize production efficiency and minimize mechanical stress on the driven equipment.

Technical Configuration

The VFD450C43S is built for dual-rating flexibility, allowing for optimization across diverse load profiles. In Normal Duty, the drive supports a 45 kW (60 HP) load with a 91 A output, while its Heavy Duty mode is configured for 37 kW (53 HP) constant-torque applications with an 86 A output. The drive's output frequency range extends up to 599.00 Hz, supported by an adjustable carrier frequency (2–10 kHz) that allows operators to balance acoustic noise reduction against internal thermal efficiency. Its robust hardware design ensures stability in demanding environments, making it a reliable backbone for complex, high-power industrial automation.

Technical Specifications

Feature Specification
Model VFD450C43S
Brand Delta
Origin Taiwan
Weight 27.0 kg
Normal Duty Power 45 kW (60 HP)
Heavy Duty Power 37 kW (53 HP)
Output Current (Normal/Heavy) 91 A / 86 A
Max Output Frequency 599.00 Hz
Series C2000 Series
Dimensions 255 mm x 280 mm x 500 mm

Frequently Asked Questions

When should I choose "Normal Duty" vs. "Heavy Duty" settings for the VFD450C43S?

Choose "Normal Duty" for variable torque applications like centrifugal fans or pumps where load torque requirements scale with speed. Choose "Heavy Duty" for constant torque applications, such as extruders, crushers, or indexing conveyors, where sustained, high-starting torque is mandatory.

What is the significance of the 2-10 kHz carrier frequency range?

The carrier frequency dictates the switching speed of the drive's output transistors. Higher frequencies (closer to 10 kHz) lead to quieter motor operation, while lower frequencies (closer to 2 kHz) generate less heat within the VFD, which is often necessary when operating the drive at its maximum rated current in hot industrial environments.

Can this drive support networked communication?

Yes, the C2000 series features a modular expansion slot. By installing the appropriate communication card, you can easily integrate this drive into PLC networks using protocols such as EtherCAT, CANopen, or Profibus.

Installation and Operational Best Practices

  • Thermal Management: Operating at 45 kW generates significant internal heat. Ensure your control cabinet is equipped with a high-CFM ventilation system. Maintain a minimum of 150 mm of vertical clearance above and below the unit to prevent thermal throttling.
  • Electrical Grounding: To minimize high-frequency EMI, bond the drive chassis to the primary machine ground bus using a short, wide copper braid. Avoid using thin, high-impedance ground wires, as they are ineffective at draining the high-frequency currents inherent in VFD operation.
  • Cable Shielding: Always use double-shielded, twisted-pair cabling for all motor connections. Ensure the shield is terminated 360 degrees at both the motor terminal box and the VFD output terminal to prevent radiated noise from interfering with nearby analog signals or communication lines.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Czarny
Country of origin
Stany Zjednoczone

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...