1 z 1

EL2904 BECKHOFF TwinSAFE 4-Channel Safety Digital Output Terminal

EL2904 BECKHOFF TwinSAFE 4-Channel Safety Digital Output Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL2904

  • Country of origin:Niemcy

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 24 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Product Overview

The EL2904 (EL 2904) is a high-integrity safety digital output terminal designed for the TwinSAFE system, enabling the secure execution of safety functions within an EtherCAT network. This 4-channel module provides 24 VDC at 0.5 A per channel and is engineered to meet the most stringent global safety standards, including SIL 3 and PL e. In high-risk industrial environments such as robotic work cells, heavy-duty pressing, and automated logistics, the EL2904 is the primary component for switching off safety-relevant actuators like contactors, signal lamps, or motor starters. By utilizing the Safety over EtherCAT (FSoE) protocol, it ensures reliable communication and rapid fault response, directly protecting personnel and machinery from operational hazards.

Technical Configuration

The EL2904 architecture is built on the TwinSAFE protocol, which allows for the integration of safety-related signals into a standard EtherCAT terminal segment. It supports both 1-wire and 2-wire connection technologies, offering flexibility in wiring actuators. The module features integrated active current measurement, requiring a minimum load of 20 mA to ensure precise monitoring of the output state. One of its core technical advantages is the parameterizable watchdog time, which dictates the fault response time in the event of a communication interruption. The hardware is housed in a 24 mm polycarbonate casing and includes ATEX marking (II 3 G Ex nA IIC T4 Gc), permitting installation in Zone 2 hazardous areas when properly enclosed.

Technical Specifications

Attribute Specification Details
Model EL2904
Brand BECKHOFF
Origin Germany
Safety Standard SIL 3 (EN 61508) / PL e (ISO 13849)
Protocol TwinSAFE / Safety over EtherCAT (FSoE)
Number of Outputs 4
Max. Output Current 0.5 A (per channel)
Nominal Voltage 24 VDC
Connection Tech 1-wire / 2-wire
Current Consumption Typ. 221 mA (E-bus)
Dimensions (W x H x D) 24 mm x 100 mm x 68 mm
Operating Temp 0 to +55 deg C (Standard)
Weight 100 g
Shipping Weight 2.0 kg

Technical FAQs

Can the EL2904 be used without a TwinSAFE Logic terminal?

No, the EL2904 is a safety slave device. It must be paired with a TwinSAFE Logic terminal (such as the EL6900, EL6910, or a TwinSAFE-capable controller) which executes the safety logic and manages the FSoE communication cycle.

What happens if the load on a channel is less than 20 mA?

The EL2904 performs active current measurement for diagnostic purposes. If the connected load is below 20 mA, the module may report a "Broken Wire" or load error because the current is too low for the internal sensors to verify the output state accurately.

How does the "Watchdog Time" parameter affect machine safety?

The watchdog time defines the maximum period the terminal will wait for a valid safety telegram before entering a "Safe State" (outputs deactivated). This must be calculated based on your total system reaction time requirements to ensure the machine reaches a stop before a hazard occurs.


Engineering & Installation Guide

TwinSAFE Address Configuration:

Every EL2904 must have a unique TwinSAFE address assigned via the DIP switches located on the side of the terminal or through TwinCAT software (depending on the hardware revision). Ensure this address matches the configuration in your TwinCAT Safety project. Failure to match these addresses will prevent the FSoE connection from establishing, resulting in a safety "Com Error."

Wiring for Safety Integrity:

For applications requiring SIL 3 or PL e, ensure that the wiring is protected against external cross-circuits. When using 2-wire technology, both the output and the corresponding 0V return should be managed to ensure the diagnostic tests (light tests) can accurately detect short circuits to the 24V supply or ground. Use the recommended stripping length of 8–9 mm for all connections to ensure a gas-tight fit in the spring-loaded terminals.

Mounting and Heat Dissipation:

The EL2904 is designed for horizontal installation on a 35 mm DIN rail. Given its higher current consumption (221 mA from the E-bus), ensure the power supply terminal (e.g., EK1100 or EK1200) can provide sufficient current for the entire segment. If the total E-bus current exceeds 2A, a power feed terminal must be inserted to prevent communication drops or overheating of the bus contacts.

 

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Żółty
Country of origin
Niemcy
Power source
Zasilanie prądem stałym

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...