1 z 3

Triconex 3009 Tricon Safety System Enhanced Main Processor UMP

Triconex 3009 Tricon Safety System Enhanced Main Processor UMP

Only 10 item(s) left in stock
  • Manufacturer: Triconex

  • Product No.: 3009

  • Country of origin:Stany Zjednoczone

  • Product Type: Enhanced Main Processor UMP

  • Payment: T/T, Western Union

  • Weight: 1800g

  • Dimensions: 31.0 cm x 22.5 cm x 4.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

The Triconex 3009 is a high-reliability Enhanced Main Processor (UMP) module designed for Triconex triple modular redundant (TMR) safety systems. As the central processing unit of the controller, this module executes complex control logic, manages high-speed inter-module data synchronization, and provides hardware majority voting to eliminate single-point failures. Built for critical control and emergency shutdown applications, the 3009 delivers absolute fault tolerance and deterministic scan execution in demanding environments such as steam/gas turbines, refinery shutdown systems, and burner management systems (BMS).

Operating autonomously with an independent dual-core architecture, the 3009 maintains isolated execution and dedicated memory verification across three parallel channels. High-speed TriBus communication links the triplicated processors, performing routine cross-channel data corrections without delaying control tasks. Fully integrated diagnostics monitor system integrity online, while hot-swappable replacement procedures ensure continuous process uptime during routine maintenance or component upgrades.

Features

  • Triple Modular Redundant (TMR) Architecture: Features three identical main processors running in parallel with separate power regulation, isolating faults and performing hardware majority voting across channels.
  • High-Speed Dual-Core Processing: Driven by an 800 MHz QorIQ P1021 dual-core processor containing dedicated cores for control applications and high-throughput I/O bus operations.
  • Scalable TriBus Interface: Delivers highly deterministic, isolated serial synchronization that supports 25 Mbps in standard 8110 main chassis and scales up to 1000 Mbps in 8120E enhanced main chassis.
  • Online Hot-Replacement: Supports direct module extraction and replacement while the controller is live, allowing the remaining healthy processors to maintain seamless safety voting and loop protection.
  • Robust Diagnostic Logging: Implements onboard hardware fault analysis alongside a battery-backed real-time clock to ensure continuous Sequence of Events (SOE) timestamp logging.
  • Industrial Grade Design: Built to withstand harsh plant environments with isolated diagnostic ports, high vibration tolerances, and strict non-condensing relative humidity handling.

Applications

  • Emergency Shutdown Systems (ESD)
  • Turbomachinery Control (Gas & Steam Turbine Over-speed Protection)
  • Burner Management Systems (BMS)
  • Boiler and Furnace Control Loops
  • Refinery and Petrochemical Process Safety Installations
  • High-Pressure Protection Systems (HIPPS)

Technical Specifications

Parameter Specification
Model 3009 Enhanced Main Processor (UMP)
Brand Triconex
Series Tricon Safety System
Architecture Triple Modular Redundant (TMR)
Main CPU QorIQ P1021 Dual Core 800 MHz
Memory 256 MB DRAM (without battery backup)
NVRAM 2 MB battery-backed SRAM
Flash Memory 128 MB Flash
TriBus Speed 25 Mbps (8110 Chassis) / 1000 Mbps (8120E Enhanced Chassis)
Communication Bus RS-485 at 2 Mbps
I/O Bus RS-485 at 375 kbps
Diagnostic Port Isolated RS-232
Logic Power Consumption < 14 W
Isolation 500 VDC (diagnostic port)
Operating Temperature 0 to 60 degC
Storage Temperature -40 to 75 degC
Humidity 5% to 95% non-condensing
System Compatibility Tricon v11.x Systems
Mounting Slot Tricon Main Chassis
Top Key Number 007
Bottom Key Number 002
Dimensions 31.0 cm x 22.5 cm x 4.0 cm
Weight 1.8 kg
Country of Origin USA

Installation Guidelines

  • Chassis Compatibility: Slot the processor only into an authorized Tricon 8110 Main Chassis or 8120E Enhanced Performance Main Chassis.
  • Slot Keying Alignment: Verify physical backplane index pins match the module's key codes (Top Key: 007, Bottom Key: 002) before inserting.
  • Firmware Configuration: All three processing modules residing within the same main chassis must run identical firmware revisions. Mixing different versions or hardware revisions across active TMR legs is prohibited.
  • Thermal Management: Maintain a clearance of at least 50 mm around the chassis ventilation pathways to guarantee proper continuous cooling airflow.
  • Shielding & Interference: Utilize high-quality shielded cables for external RS-485 serialization ports. Ensure the ground shield is terminated strictly at one end to reduce communication signal noise.
  • Battery Maintenance: Swap out the lithium backup batteries during your site's scheduled periodic system maintenance to safeguard the functionality of the onboard real-time clock and persistent data tables during an outage.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Triconex 3009 Tricon Safety System Enhanced Main Processor UMP

Is the module compatible with older Tricon control platforms?

No. The module is strictly designed for Tricon v11.x systems and must be installed within a Model 8110 or Model 8120E main chassis. Precise firmware alignment across the controller configuration is mandatory prior to commission.

Can the processor be hot-swapped while the process is online?

Yes. The module fully supports hot replacement. The remaining active processors preserve control loops and process safety logic during the exchange, utilizing cross-channel voting to eliminate signal output disturbances.

What error events trigger a diagnostic fault indication on the device?

Hardware faults are immediately broadcast by on-module LEDs showing ACTIVE, PASS, or FAIL states. Internal diagnostics track and report errors including TriBus network anomalies, active memory mismatches, and hardware watchdog timeouts.

Can this module replace an obsolete 3008 main processor?

Yes. The module functions as a high-performance direct upgrade pathway for legacy 3008 series architectures. Upgrading requires software firmware migration and a full database configuration re-download using TriStation software.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Czarny
Country of origin
Stany Zjednoczone
Power source
Zasilany prądem zmiennym Zasilany baterią

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...