Woodward

5430-929 | Woodward | Magnetic Pickup c/w 2-Pin Plug Connector

SKU 5430-929

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Woodward

  • Product No.: 5430-929

  • Country of origin:United States

  • Product Type: Magnetic Pickup Speed Sensor

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: Approximately 3.0 to 4.5 inches

  • Shipping port: Xiamen

  • Warranty: 12 months

The Woodward 5430-929 is a high-precision Magnetic Pickup (MPU) sensor equipped with a 2-pin plug connector. It serves as the primary speed-sensing component for engine governors and electronic control systems, converting the mechanical motion of a gear (usually the engine flywheel) into an electrical frequency signal.

Technical Specifications

Category Specification
Manufacturer Woodward
Product Number 5430-929
Product Type Magnetic Speed Sensor (MPU)
Connector Type 2-Pin Plug Connector
Output Signal AC Sine Wave (Frequency proportional to speed)
Housing Material Stainless Steel (Corrosion resistant)
Shipping Weight 2.0 kg

Installation Guidelines

  • Air Gap Setting: The performance of the MPU is highly dependent on the air gap between the sensor tip and the gear teeth. A typical starting point is to screw the MPU in until it touches a gear tooth, then back it out 1/2 to 3/4 of a turn before tightening the jam nut.

  • Alignment: Ensure the sensor is centered over the gear teeth. Improper alignment can lead to weak signal strength or "ghost" speed readings.

  • Wiring: Use shielded, twisted-pair cabling for the 2-pin connector. The shield should be grounded at the control system end only to prevent electromagnetic interference (EMI) from the ignition system or alternator.

  • Environment: The sensor is designed for high-vibration engine environments, but ensure the plug connector is securely seated and protected from direct exposure to excessive oil or high-pressure washdowns.


Frequently Asked Questions (FAQs)

How does the Magnetic Pickup work?

As the teeth of a ferrous gear pass the tip of the sensor, the magnetic field is interrupted, inducing an AC voltage in the internal coil. The frequency of this voltage is interpreted by the Woodward governor as the engine's RPM.

Does the 5430-929 require an external power supply?

No. Magnetic pickups are passive sensors. They generate their own AC voltage through electromagnetic induction as the gear rotates.

What are the symptoms of a failing MPU?

Common signs include erratic engine speed readings, "speed loss" shutdowns on the controller, or an inability for the engine to start because the governor cannot detect cranking RPM.

Can I test the sensor with a multimeter?

Yes. You can check the internal coil resistance across the 2 pins (typically between 100 to 300 ohms, depending on the model). Additionally, you can check for AC voltage (usually 1V AC or higher) while the engine is cranking.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.