1 of 3

ABB HESG447220R4 70EB02C-ES Procontrol P13/P14 Input Module

ABB HESG447220R4 70EB02C-ES Procontrol P13/P14 Input Module

Only 2 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: HESG447220R4 70EB02C-ES

  • Country of origin:Sweden

  • Product Type: Power Supply Units

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 1.6 x 20 x 14.7 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ABB HESG447220R4 70EB02C-ES is a specialized input module designed for contact signal acquisition within ABB Procontrol P13 and P14 automation systems. As an essential interface device, the HESG447220R4 70EB02C-ES converts signals from field single-throw or double-throw contacts into a 16-bit binary word for system logic processing. The module provides 48Vdc wetting voltage for dry-contact devices, enabling fast data update rates of 50us across 16 logic channels.

Features

  • 16 contact input channels for 48Vdc logic signals
  • Integrated 48Vdc wetting power for dry contact devices
  • Fast 50us data update rate for real-time signal monitoring
  • 16-bit binary word output data format
  • Mobile device and desktop diagnosis capabilities
  • Compatible with both single-throw and double-throw contact configurations

Applications

  • Power generation control systems
  • Industrial automation processes using ABB Procontrol P13/P14 platforms
  • Field contact state monitoring and signal processing

Technical Specifications

Parameter Specification
Manufacturer ABB
Product Model 70EB02C-ES
Spare Model HESG447220R4
Tariff Code 8537101190
Country of Origin SWEDEN
Place of Shipment Xiamen, China
Dimensions 1.6 x 20 x 14.7 cm
Weight 0.2 kg
Number of Channels 16 (8)
Input Types 48Vdc (24Vdc)
Input Resistance 9k ohm to -24V
Connection Types Single throw or double throw contacts
Logic '0' Level -24Vdc to 0Vdc
Logic '1' Level +2Vdc to +30Vdc
Data Update Rate 50us
Input Response 22Hz
Wetting Voltage 48Vdc for dry contact devices
Output Format 16-bit Binary Word
Min Operating Voltage +19.5Vdc
Max Operating Voltage +30Vdc
Max Input Voltage 50V

Installation Guidelines

  • Ensure the power supply matches the module operating voltage limits (+19.5Vdc to +30Vdc) prior to installation.
  • Verify input contact connections for single-throw or double-throw configurations to ensure proper dry contact wetting.
  • Maintain proper field cabling routing to reduce electromagnetic interference (EMI) on logic input signals.
  • Securely seat the module into the Procontrol rack system to ensure robust backplane connectivity.
Loading product navigation…

What is the primary function of this module?

The module serves as a 16-channel contact input interface that provides 48Vdc wetting voltage to field contacts and processes signals into a 16-bit binary output format for the control system.

What input connection types are supported by the device?

The module supports both single-throw and double-throw contact connections.

What are the logic voltage threshold levels for the inputs?

Logic '0' level ranges from -24Vdc to 0Vdc, while Logic '1' level ranges from +2Vdc to +30Vdc.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
Sweden
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...