ABB

ABB IMMFP12 Bailey infi 90 Multi-Function Processor Module

SKU IMMFP12

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: IMMFP12

  • Country of origin:Switzerland

  • Product Type: DCS Multi-Function Processor Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 600g

  • Dimensions: 35.56 x 177.80 x 298.45 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

IMMFP12 functions as a multi-loop analog, sequential, batch, and function-code controller within the INFI 90 OPEN system. It performs process control, data acquisition, and information processing while supporting peer-to-peer communication between intelligent modules.

The processor exchanges process data with analog and digital I/O modules through the I/O Expander Bus. It can communicate with up to 64 low-power I/O modules in any combination. The internal DMA circuitry transfers communication data directly to or from RAM without continuous microprocessor intervention.

Two general-purpose serial channels support station and external device communication. The module also provides Controlway communication, module bus operation, and a dedicated processor redundancy link.

A primary and backup processor can operate in a redundant configuration. The backup remains in hot standby and receives block output data from the primary processor. Control transfers to the backup processor if the primary processor goes offline.

Features

  • Multiple-loop analog control
  • Sequential and batch control execution
  • Function-code-based control strategy processing
  • Data acquisition and information processing
  • Peer-to-peer communication between intelligent modules
  • Primary and hot standby processor redundancy
  • Bumpless control transfer between redundant processors
  • Execute, configure, and error operating modes
  • DMA-assisted communication data transfer
  • Front-panel status and diagnostic LED indication
  • Combination stop and reset pushbutton
  • Nonvolatile storage of the module configuration

Applications

  • Multiple-loop analog process control
  • Sequential equipment control
  • Batch process control
  • Analog and digital I/O coordination
  • Process data acquisition
  • Control strategy information processing
  • Redundant process control units
  • Operator station communication
  • INFI 90 OPEN control system modernization
  • Compatible Network 90 system configurations

Connections/Interfaces

P1 Card Edge Connector

Connector Pin Function
1 +5 VDC
2 +5 VDC
3 -30 VDC or power supply status
4 Controlway B
5 Common
6 Common
7 +15 VDC
8 -15 VDC
9 Power Fail Interrupt
10 Unused
11 Controlway A or Module Bus
12 Unused

Pin 3 carries -30 VDC in early Network 90 systems. It carries the power supply status signal in newer Network 90 and INFI 90 systems.

P2 Card Edge Connector

Connector Pin Function
1 Data Bit 1
2 Data Bit 0
3 Data Bit 3
4 Data Bit 2
5 Data Bit 5
6 Data Bit 4
7 Data Bit 7
8 Data Bit 6
9 Bus Clock
10 Synchronization
11 Reserved
12 Reserved

All P2 data bits are true low.

P3 Card Edge Connector

Connector Pin Function Connector Pin Function
1 DCS A (-) 16 DCS A (+)
2 DCS B (-) 17 DCS B (+)
3 Redundancy Transmit (-) 18 Redundancy Transmit (+)
4 Redundancy Transmit Clock (-) 19 Redundancy Transmit Clock (+)
5 Redundancy Receive (-) 20 Redundancy Receive (+)
6 Redundancy Receive Clock (-) 21 Redundancy Receive Clock (+)
7 Receive A (-) 22 Receive A (+)
8 Receive B (-) 23 Receive B (+)
9 Clear to Send A (-) 24 Clear to Send A (+)
10 Clear to Send B (-) 25 Clear to Send B (+)
11 Transmit A (-) 26 Transmit A (+)
12 Transmit B (-) 27 Transmit B (+)
13 Request to Send A (-) 28 Request to Send A (+)
14 Request to Send B (-) 29 Request to Send B (+)
15 Digital Output (+) 30 Digital Output (-)

Installation Guidelines

  • Verify module mounting unit compatibility before installation.
  • Check whether the backplane supplies -30 VDC before setting jumper J5.
  • Use a grounded wrist strap when handling the circuit board.
  • Keep the module inside its static shielding bag until installation.
  • Handle the assembly by its edges and avoid touching circuitry.
  • Verify all SW3 and SW4 dipswitch settings before operation.
  • Verify jumpers J1 through J5 before inserting the module.
  • Use identical module addresses for redundant processors.
  • Use matching SW4 settings for redundant processors.
  • Verify matching firmware revisions in primary and backup processors.
  • Disconnect cabinet power before installing backplane dipshunts.
  • Install 24-pin dipshunts between associated I/O Expander Bus slots.
  • Keep Controlway-linked mounting units within the same cabinet.
  • Do not connect more than eight related mounting units in one cabinet.
  • Connect NTMP01, NIMP01, or NIMP02 termination hardware using the specified cables.
  • Confirm all cables connect to the assigned module mounting unit slot.
  • Seat the module firmly in the backplane connectors.
  • Secure the module using both faceplate latching screws.
  • Keep cabinet doors closed during operation.
  • Keep portable communication equipment at least 2 meters from the cabinet.
  • Operate and store the module in a noncorrosive environment.

Compliance and Certifications

  • CSA certified for use as process control equipment in an ordinary nonhazardous location.
  • Factory Mutual approved for use in Class I, Division 2 hazardous locations.

FAQ

What control functions does the module support?

The module supports multiple-loop analog, sequential, batch, and function-code control. It also performs data acquisition and information processing.

How many I/O modules can it communicate with?

The processor can communicate with up to 64 low-power analog and digital I/O modules through the I/O Expander Bus.

How does processor redundancy operate?

A 1 Mbaud redundancy link connects the primary and backup processors. The backup remains in hot standby and takes control if the primary processor fails.

Which serial interfaces are available?

The module supports two RS-232-C ports, or one RS-485 port and one RS-232-C port. Serial communication rates reach 19.2 kbaud.

What is the specified operating temperature range?

The specified ambient operating temperature range is 0 to 70 degC.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB IMMFP12 Bailey infi 90 Multi-Function Processor Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Switzerland

Technical knowledge

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics