ABB

ABB IMSED01 Harmony Sequence of Events Digital Input Module

SKU IMSED01

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: IMSED01

  • Country of origin:Switzerland

  • Product Type: Sequence of Events Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 2.5 cm x 17.8 cm x 29.8 cm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ABB IMSED01 Harmony Sequence of Events Digital Input Module provides distributed event monitoring, recording, and reporting capabilities for the Symphony Enterprise Management and Control System. It monitors digital signal transitions from either on to off or from off to on. These digital state transitions are collected at the Harmony Control Unit (HCU) level and forwarded to the INSEM01 Master module for time-stamping, sorting, and storage in an internal database. The module processes up to 16 digital field inputs for its designated Harmony controller. It does not process time synchronization link information directly, relying instead on its controller to interface configuration and access data. The module consists of a single printed circuit board that installs inside a dedicated slot within a module mounting unit.

Features

  • Processes up to 16 digital field inputs for the Harmony controller.
  • Interfaces via function code 242 (SOE digital event interface) to configure and access module input channels.
  • Supports up to 63 modules operating concurrently on a single I/O expander bus segment along with one IMSET01 module.
  • Connects to an NTDI01 termination unit via cable for external process field wiring terminations.
  • Configurable I/O channels through jumpers and switches on the printed circuit board.

Applications

  • Symphony Enterprise Management and Control System networks
  • Distributed sequence of events monitoring and recording
  • Harmony Control Unit digital event collection

Technical Specifications

Property Characteristic / Value
Manufacturer ABB
Mounting Occupies one slot in a standard module mounting unit
Operating Voltage +5 VDC, 15%
Current (Typical) 350 mA
Microprocessor 16 bits running at 10 MHz
Memory 64 kb RAM, 64 kb ROM
Digital Inputs Up to 16 digital field inputs
Input Voltages (with +/-10% tolerance) 24 VDC, 48 VDC, 125 VDC, 120 VAC (only for system control logic)
Typical Input Current 5 mA (24 VDC), 4 mA (48 VDC), 4 mA (125 VDC), 5 mA (120 VAC)
Minimum Turn On Voltage 21.6 VDC (24 VDC), 43.2 VDC (48 VDC), 112.5 VDC (125 VDC), 108 VAC (120 VAC)
Maximum Turn Off Voltage 10 VDC (24 VDC), 20 VDC (48 VDC), 50 VDC (125 VDC), 50 VAC (120 VAC)
Maximum Input Current at Minimum Turn On 4 mA (21.6 VDC), 4.4 mA (43.2 VDC), 3.2 mA (112.5 VDC), 4 mA (108 VAC)
Maximum Off-Leakage Current 1.5 mA (for all DI voltages)
Typical Response Time DC fast: 1.1 msec; DC slow: 18 msec; AC: 5 msec after first positive half cycle
Isolation 1,000 VDC/VRMS channel to system; 50 VDC/VRMS channel to channel
Surge Protection Meets IEEE-472-1974 surge withstand capability test
Ambient Temperature 0 to 70 degC (32 to 158 degF)
Relative Humidity 5% to 95% up to 55 degC (131 degF) noncondensing; 5% to 45% at 70 degC (158 degF) noncondensing
Pollution Degree I
Altitude Sea level to 3 km (1.86 mi)
Air Quality Noncorrosive

Installation Guidelines

  • Hardware Configuration: Before inserting the module, adjust onboard jumpers and switches to set up hardware constraints. Ensure dispshunts on the related termination unit match the configuration needs of individual I/O channels.
  • Bus Limitations: Verify that no more than 63 digital input modules are connected along the same I/O expander bus segment.
  • Module Mounting: Place the single printed circuit board squarely inside its intended slot within the module mounting unit.
  • Field Wiring: Direct all physical field cabling points exclusively to the external NTDI01 termination unit.

Compliance and Certifications

  • CE Mark Declaration: Complies with EMC96 Directive 89/336/EEC (EN50082-2 Generic Immunity Standard - Part 2: Industrial Environment and EN50081-2 Generic Emission Standard - Part 2: Industrial Environment) and Low Voltage Directive 73/23/EEC (EN61010-1 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use) when installed in a Symphony cabinet.
  • Canadian Standards Association (CSA): Certified for use as process control equipment in an ordinary (nonhazardous) location.
  • Factory Mutual (FM): Pending approval for Nonincendive: Class I Division 2, Groups A, B, C, D and Class II, Division 2, Groups F, G.

FAQ

How many digital inputs can the module process?

The module is designed to process up to 16 digital field inputs for the controller.

What is the maximum number of these digital modules allowed on a single bus segment?

Up to 63 modules can operate together on a single I/O expander bus segment alongside one timing module.

What function code is used to interface with the module?

The controller utilizes function code 242, which represents the SOE digital event interface, to configure and access the input channels of the module.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB IMSED01 Harmony Sequence of Events Digital Input Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Switzerland
Power source
DC Power

Technical knowledge

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...