The ABB INLIM03, a component of the Bailey Infi 90 system, is a specialized Loop Interface Module designed to manage critical data routing and transmission between individual process control equipment and the primary communication backbone. Operating in tandem with an accompanying Bus Interface Module (INBIM02) via a dedicated ribbon cable link, this device handles complex multi-node orchestration tasks without relying on a centralized master traffic controller. By serving as a localized gateway, the module helps isolate high-throughput automated adjustments from macro-level loop congestion.

Applications

  • Process Control Units (PCU) communication bridging
  • High-speed serial data transmission within industrial Plant Loops
  • Redundant network topology orchestration in process management setups
  • Distributed multi-node process architecture data routing

Technical Specifications

Parameter Specification
Manufacturer ABB / Elsag Bailey
Model INLIM03
Series Infi 90
Module Type Loop Interface Module
Memory Capacity 2 kbytes RAM, 4 kbytes ROM
Power Consumption +5 VDC @ 2.0 Amps (10 Watts nominal); ±15 VDC @ 80 mA (1.2 Watts nominal)
Communication Speed 500 kbaud
Maximum System Capacity Up to 63 nodes per loop
Maximum Data Throughput 800 messages/second maximum
Maximum Synchronization Time 100 milliseconds
Operating Temperature Range 0 to 70 degC (32 to 158 Fahrenheit)
Operating Relative Humidity 0% to 95% up to 55 degC; 0% to 45% up to 70 degC (non-condensing)
Atmospheric Pressure Range Sea level to 3 km
Maximum Node-to-Node Distance 2000 meters (6561 feet)
Maximum Module-to-Termination Distance 61 meters (200 feet)

Connections/Interfaces

Connector Pin Function
P1 - Pin 1 +5 VDC Power Input
P1 - Pin 2 +5 VDC Power Input
P1 - Pin 5 Power Common
P1 - Pin 6 Power Common
P1 - Pin 7 +15 VDC Power Input
P1 - Pin 8 -15 VDC Power Input
P3 - Pin 1 Loop 2 In (+)
P3 - Pin 2 Loop 2 In (-)
P3 - Pin 3 Cable Shield
P3 - Pin 4 Loop 1 Out (+)
P3 - Pin 5 Loop 1 Out (+)
P3 - Pin 6 Loop 1 In (+)
P3 - Pin 7 Loop 1 In (-)
P3 - Pin 8 Cable Shield
P3 - Pin 9 Loop 2 Out (+)
P3 - Pin 10 Loop 2 Out (+)
P3 - Pin 11 Cable Shield
P3 - Pin 13 Loop 2 Bypass Control
P3 - Pin 14 Cable Shield
P3 - Pin A Shield
P3 - Pin D Loop 1 Out (-)
P3 - Pin E Loop 1 Out (-)
P3 - Pin F Cable Shield
P3 - Pin H Loop 2 Bypass Control Cable
P3 - Pin K Loop 2 Out (-)
P3 - Pin L Loop 2 Out (-)
P3 - Pin M Cable Shield
P3 - Pin S Cable Shield
P4 Ribbon Cable Connection to Bus Interface Module (BIM)

Installation Guidelines

  • Static Dissipative Measures: Technicians must utilize grounded wrist straps and appropriate static dissipative work surfaces prior to handling to safeguard internal circuitry from electrostatic discharge.
  • Dipswitch Configurations: Set the S1 option dipswitch to the desired event tracking address (default position: Hex 30) and configure the S2 address dipswitch to establish a unique node designation from 1 to 63.
  • Module Interconnection: Securely connect the ribbon cable between the P4 slot of the device and the corresponding P4 slot of the partner module before inserting the joined assembly into the frame.
  • Physical Slot Mount: Slide the unit directly along the plastic guide rails within the designated Module Mounting Unit (MMU) slot until the front faceplate rests flush with the upper and lower framing edges.
  • Faceplate Locking: Hand-tighten the dual captive faceplate screws by rotating each a 1/2 turn to lock the hardware firmly into position within the chassis card cage.
  • Cable Orientation Warning: When completing termination paths using the dedicated cabling assembly, confirm that the designated J1 cable ending attaches to the terminal card edge (P1 connector) and the J2 ending seats properly directly onto the device module. Incorrect configuration can cause immediate electrical damage.

Compliance and Certifications

  • CSA certified for use as process control equipment in ordinary, non-hazardous environments.

FAQ

What is the primary function of the module within the system?

The module serves as the primary communication interface between the Process Control Units (PCU) and the high-speed serial Plant Loop communication highway.

What data rates does the communication interface support?

The communication network operates at a rate of 500 kbaud, handling a maximum transmission capacity of up to 800 messages per second.

Can the module be inserted or removed while the rack is energized?

Yes. The device can be inserted or removed under live power conditions, as there are no hazardous voltage levels present on the module interface.

How are hardware events and transmission metrics monitored on the module?

The device contains internal event and error counters whose specific cumulative byte-wide values can be output directly onto the front faceplate LEDs by setting the S1 option dipswitch to the target hexadecimal counter address.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB INLIM03 Bailey Infi 90 Loop Interface Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.